Accuracy of Portable Face-Scanning Devices for Obtaining Three-Dimensional Face Models: A Systematic Review and Meta-Analysis

被引:24
作者
Mai, Hang-Nga [1 ]
Kim, Jaeil [2 ]
Choi, Youn-Hee [1 ,3 ]
Lee, Du-Hyeong [1 ,4 ]
机构
[1] Kyungpook Natl Univ, Inst Translat Res Dent, Daegu 41940, South Korea
[2] Kyungpook Natl Univ, Sch Comp Sci & Engn, Daegu 41940, South Korea
[3] Kyungpook Natl Univ, Sch Dent, Dept Prevent Dent, Daegu 41940, South Korea
[4] Kyungpook Natl Univ, Sch Dent, Dept Prosthodont, Daegu 41940, South Korea
关键词
accuracy; three-dimensional face model; portable facial scanning; systematic review; meta-analysis; FACIAL ANATOMY; REPRODUCIBILITY; RELIABILITY; VALIDATION; PHOTOGRAMMETRY;
D O I
10.3390/ijerph18010094
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The use of three-dimensional face-scanning systems to obtain facial models is of increasing interest, however, systematic assessments of the reliability of portable face-scan devices have not been widely conducted. Therefore, a systematic review and meta-analysis were performed considering the accuracy of facial models obtained by portable face-scanners in comparison with that of those obtained by stationary face-scanning systems. A systematic literature search was conducted in electronic databases following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines for articles published from 1 January 2009 to 18 March 2020. A total of 2806 articles were identified, with 21 articles available for the narrative review and nine studies available for meta-analysis. The meta-analysis revealed that the accuracy of the digital face models generated by the portable scanners was not significantly different from that of the stationary face-scanning systems (standard mean difference (95% confidence interval) = -0.325 mm (-1.186 to 0.536); z = -0.74; p = 0.459). Within the comparison of the portable systems, no statistically significant difference was found concerning the accuracy of the facial models among scanning methods (p = 0.063). Overall, portable face-scan devices can be considered reliable for obtaining facial models. However, caution is needed when applying face-scanners with respect to scanning device settings, control of involuntary facial movements, landmark and facial region identifications, and scanning protocols.
引用
收藏
页码:1 / 15
页数:15
相关论文
共 53 条
[11]   Smartphone Application as a Low-Cost Alternative for Digitizing Facial Defects: Is It Accurate Enough for Clinical Application? [J].
Elbashti, Mahmoud E. ;
Sumita, Yuka, I ;
Aswehlee, Amel M. ;
Seelaus, Rosemary .
INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2019, 32 (06) :541-543
[12]   Influence of Intra-Oral Scanner (IOS) on The Marginal Accuracy of CAD/CAM Single Crowns [J].
Ferrini, Francesco ;
Sannino, Gianpaolo ;
Chiola, Carlo ;
Cappare, Paolo ;
Gastaldi, Giorgio ;
Gherlone, Enrico Felice .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2019, 16 (04)
[13]   Image quality degradation by light scattering in display devices [J].
Flynn, MJ ;
Badano, A .
JOURNAL OF DIGITAL IMAGING, 1999, 12 (02) :50-59
[14]   Evaluation of anthropometric accuracy and reliability using different three-dimensional scanning systems [J].
Fourie, Zacharias ;
Damstra, Janalt ;
Gerrits, Peter O. ;
Ren, Yijin .
FORENSIC SCIENCE INTERNATIONAL, 2011, 207 (1-3) :127-134
[15]   Comparison of Facial Soft Tissue Measurements on Three-Dimensional Images and Models Obtained With Different Methods [J].
Germec-Cakan, Derya ;
Canter, Halil Ibrahim ;
Nur, Burcu ;
Arun, Tulin .
JOURNAL OF CRANIOFACIAL SURGERY, 2010, 21 (05) :1393-1399
[16]   Three-dimensional maps of human skin properties on full face with shadows using 3-D hyperspectral imaging [J].
Gevaux, Lou ;
Adnet, Cyprien ;
Seroul, Pierre ;
Clerc, Raphael ;
Tremeau, Alain ;
Perrot, Jean Luc ;
Hebert, Mathieu .
JOURNAL OF BIOMEDICAL OPTICS, 2019, 24 (06)
[17]   Digital Impressions for Fabrication of Definitive "All-on-Four" Restorations [J].
Gherlone, Enrico Felice ;
Ferrini, Francesco ;
Crespi, Roberto ;
Gastaldi, Giorgio ;
Cappare, Paolo .
IMPLANT DENTISTRY, 2015, 24 (01) :125-129
[18]   Reliability of optical devices for three-dimensional facial anatomy description: a systematic review and meta-analysis [J].
Gibelli, D. ;
Dolci, C. ;
Cappella, A. ;
Sforza, C. .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2020, 49 (08) :1092-1106
[19]   Validation of a low-cost laser scanner device for the assessment of three-dimensional facial anatomy in living subjects [J].
Gibelli, Daniele ;
Pucciarelli, Valentina ;
Caplova, Zuzana ;
Cappella, Annalisa ;
Dolci, Claudia ;
Cattaneo, Cristina ;
Sforza, Chiarella .
JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2018, 46 (09) :1493-1499
[20]   Are Portable Stereophotogrammetric Devices Reliable in Facial Imaging? A Validation Study of VECTRA H1 Device [J].
Gibelli, Daniele ;
Pucciarelli, Valentina ;
Cappella, Annalisa ;
Dolci, Claudia ;
Sforza, Chiarella .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2018, 76 (08) :1772-1784