Refocused primary echo: A zero dead time detection of the electron spin echo envelope modulation

被引:25
作者
Astashkin, AV [1 ]
Raitsimring, AM [1 ]
机构
[1] Univ Arizona, Dept Chem, Tucson, AZ 85721 USA
基金
美国国家卫生研究院; 美国国家科学基金会;
关键词
ESE; ESEEM; dead time; sum combination line; matrix line suppression;
D O I
10.1006/jmre.1999.1988
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We report on the two-dimensional (2D) implementation of the refocused primary electron spin echo envelope modulation (ESEEM) technique, its theory and experimental application to a model system and a system of biological interest. This technique is virtually free of dead time along one time coordinate. The ESEEM obtained by integration of the 2D time-domain data of the refocused primary ESEEM over one of the time coordinates shows the intensity of the sum combination harmonics proportional to k(2) for k much less than 1 and proportional to k for k similar to 1 (k is a usual notation for the modulation amplitude factor). This feature, in combination with the adjustment of k by means of variation of the operational frequency of the spectrometer, was found to be very useful for detection of protons with distributed hyperfine interaction parameters situated close to the electron spin. (C) 2000 Academic Press.
引用
收藏
页码:280 / 291
页数:12
相关论文
共 21 条
[1]   AN ELECTRON-SPIN ECHO ENVELOPE MODULATION STUDY OF THE PRIMARY ACCEPTOR QUINONE IN ZN-SUBSTITUTED PLANT PHOTOSYSTEM-II [J].
ASTASHKIN, AV ;
KAWAMORI, A ;
KODERA, Y ;
KUROIWA, S ;
AKABORI, K .
JOURNAL OF CHEMICAL PHYSICS, 1995, 102 (14) :5583-5588
[2]   SPECTROMETER DEAD TIME - EFFECT ON ELECTRON-SPIN ECHO MODULATION SPECTRA IN DISORDERED-SYSTEMS [J].
ASTASHKIN, AV ;
DIKANOV, SA ;
TSVETKOV, YD .
CHEMICAL PHYSICS LETTERS, 1987, 136 (02) :204-208
[3]  
ASTASHKIN AV, 1998, 40 ROCK MOUNT C AN C
[4]  
ASTASHKIN AV, 1999, 41 ROCK MOUNT C AN C, P69
[5]   NUCLEAR INDUCTION IN INHOMOGENEOUS FIELDS [J].
BLOOM, AL .
PHYSICAL REVIEW, 1955, 98 (04) :1105-1111
[6]   Multifrequency two-dimensional Fourier transform ESR: An X/Ku-band spectrometer [J].
Borbat, PP ;
Crepeau, RH ;
Freed, JH .
JOURNAL OF MAGNETIC RESONANCE, 1997, 127 (02) :155-167
[7]   ZERO DEADTIME PULSED ESR BY REMOTE ECHO DETECTION [J].
CHO, H ;
PFENNINGER, S ;
GEMPERLE, C ;
SCHWEIGER, A ;
ERNST, RR .
CHEMICAL PHYSICS LETTERS, 1989, 160 (04) :391-395
[8]   USE OF A MICROWAVE DELAY-LINE TO REDUCE THE DEAD TIME IN ELECTRON-SPIN ECHO ENVELOPE SPECTROSCOPY [J].
DAVIS, JL ;
MIMS, WB .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1981, 52 (01) :131-132
[9]   ELIMINATION OF THE MATRIX CONTRIBUTION TO ELECTRON-SPIN ECHO MODULATION [J].
DIKANOV, SA ;
ASTASHKIN, AV ;
TSVETKOV, YD .
CHEMICAL PHYSICS LETTERS, 1988, 144 (03) :251-257
[10]   Making hyperfine selection in Mims ENDOR independent of deadtime [J].
Doan, PE ;
Hoffman, BM .
CHEMICAL PHYSICS LETTERS, 1997, 269 (3-4) :208-214