In vivo quantification of hydrogen gas concentration in bone marrow surrounding magnesium fracture fixation hardware using an electrochemical hydrogen gas sensor

被引:28
作者
Zhao, Daoli [1 ]
Brown, Andrew [2 ,3 ,4 ]
Wang, Tingting [1 ]
Yoshizawa, Sayuri [2 ,3 ]
Sfeir, Charles [2 ,3 ,4 ,5 ]
Heineman, William R. [1 ]
机构
[1] Univ Cincinnati, Dept Chem, 301 Clifton Court, Cincinnati, OH 45221 USA
[2] Univ Pittsburgh, Dept Periodont & Preventat Dent, 3501 Terrace St, Pittsburgh, PA 15261 USA
[3] Univ Pittsburgh, Ctr Craniofacial Regenerat, 335 Sutherland Dr, Pittsburgh, PA 15261 USA
[4] Univ Pittsburgh, Dept Bioengn, 3700 OHara St, Pittsburgh, PA 15261 USA
[5] Univ Pittsburgh, McGowan Inst Regenerat Med, 450 Technol Dr, Pittsburgh, PA 15219 USA
基金
美国国家科学基金会;
关键词
Magnesium; MicroCT; Fixation devices; Fracture fixation; Amperometric hydrogen sensor; MONITORING BIODEGRADATION; ALLOYS; DEGRADATION; VITRO; CORROSION; SCREW; RABBIT; BIOMATERIALS; REGENERATION; IMPLANTS;
D O I
10.1016/j.actbio.2018.04.032
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Magnesium (Mg) medical devices are currently being marketed for orthopedic applications and have a complex degradation process which includes the evolution of hydrogen gas (H-2). The effect of H-2 exposure on relevant cell types has not been studied; and the concentration surrounding degrading Mg devices has not been quantified to enable such mechanistic studies. A simple and effective method to measure the concentration of H-2 in varying microenvironments surrounding Mg implants is the first step to understanding the biological impact of H-2 on these cells. Here, the in vivo measurement of H-2 surrounding fracture fixation devices implanted in vivo is demonstrated. An electrochemical H-2 microsensor detected increased levels of H-2 at three anatomical sites with a response time of about 30 s. The sensor showed the H-2 concentration in the bone marrow at 1 week post-implantation (1460 +/- 320 mu M) to be much higher than measured in the subcutaneous tissue (550 +/- 210 mu M) and at the skin surface (120 +/- 50 mu M). Additionally, the H-2 concentrations measured in the bone marrow exceeded the concentration in a H-2 saturated water solution (similar to 800 mu M). These results suggest that H-2 emanating from Mg implants in bone during degradation pass through the bone marrow and become at least partially trapped because of slow permeation through the bone. This study is the first to identify H-2 concentrations in the bone marrow environment and will enable in vitro experiments to be executed at clinically relevant H-2 concentrations to explore possible biological effects of H-2 exposure. Statement of Significance An electrochemical H-2 sensor was used to monitor the degradation of a Mg fracture fixation system in a lapine ulna fracture model. Interestingly, the H-2 concentration in the bone marrow is 82% higher than H-2 saturated water solution. This suggests H-2 generated in situ is trapped in the bone marrow and bone is less permeable than the surrounding tissues. The detectable H-2 at the rabbit skin also demonstrates a H-2 sensor's ability to monitor the degradation process under thin layers of tissue. H-2 sensing shows promise as a tool for monitoring the degradation of Mg alloy in vivo and creating in vitro test beds to more mechanistically evaluate the effects of varying H-2 concentrations on cell types relevant to osteogenesis. (C) 2018 Published by Elsevier Ltd on behalf of Acta Materialia Inc.
引用
收藏
页码:559 / 566
页数:8
相关论文
共 44 条
  • [1] Review of Recent Developments in the Field of Magnesium Corrosion
    Atrens, Andrej
    Song, Guang-Ling
    Liu, Ming
    Shi, Zhiming
    Cao, Fuyong
    Dargusch, Matthew S.
    [J]. ADVANCED ENGINEERING MATERIALS, 2015, 17 (04) : 400 - 453
  • [2] Non-invasive pH determination adjacent to degradable biomaterials in vivo
    Bartsch, Ivonne
    Willbold, Elmar
    Rosenhahn, Bodo
    Witte, Frank
    [J]. ACTA BIOMATERIALIA, 2014, 10 (01) : 34 - 39
  • [3] The Bioresorption and Guided Bone Regeneration of Absorbable Hydroxyapatite-Coated Magnesium Mesh
    Byun, Soo-Hwan
    Lim, Ho-Kyung
    Kim, Soung-Min
    Lee, Sung-Mi
    Kim, Hyoun-Ee
    Lee, Jong-Ho
    [J]. JOURNAL OF CRANIOFACIAL SURGERY, 2017, 28 (02) : 518 - 523
  • [4] Biodegradability engineering of biodegradable Mg alloys: Tailoring the electrochemical properties and microstructure of constituent phases
    Cha, Pil-Ryung
    Han, Hyung-Seop
    Yang, Gui-Fu
    Kim, Yu-Chan
    Hong, Ki-Ha
    Lee, Seung-Cheol
    Jung, Jae-Young
    Ahn, Jae-Pyeong
    Kim, Young-Yul
    Cho, Sung-Youn
    Byun, Ji Young
    Lee, Kang-Sik
    Yang, Seok-Jo
    Seok, Hyun-Kwang
    [J]. SCIENTIFIC REPORTS, 2013, 3
  • [5] In vivo study of magnesium plate and screw degradation and bone fracture healing
    Chaya, Amy
    Yoshizawa, Sayuri
    Verdelis, Kostas
    Myers, Nicole
    Costello, Bernard J.
    Chou, Da-Tren
    Pal, Siladitya
    Maiti, Spandan
    Kumta, Prashant N.
    Sfeir, Charles
    [J]. ACTA BIOMATERIALIA, 2015, 18 : 262 - 269
  • [6] Fracture Healing Using Degradable Magnesium Fixation Plates and Screws
    Chaya, Amy
    Yoshizawa, Sayuri
    Verdelis, Kostas
    Noorani, Sabrina
    Costello, Bernard J.
    Sfeir, Charles
    [J]. JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2015, 73 (02) : 295 - 305
  • [7] Recent advances on the development of magnesium alloys for biodegradable implants
    Chen, Yongjun
    Xu, Zhigang
    Smith, Christopher
    Sankar, Jag
    [J]. ACTA BIOMATERIALIA, 2014, 10 (11) : 4561 - 4573
  • [8] High-purity magnesium interference screws promote fibrocartilaginous entheses regeneration in the anterior cruciate ligament reconstruction rabbit model via accumulation of BMP-2 and VEGF
    Cheng, Pengfei
    Han, Pei
    Zhao, Changli
    Zhang, Shaoxiang
    Wu, Hongliu
    Ni, Jiahua
    Hou, Peng
    Zhang, Yuanzhuang
    Liu, Jingyi
    Xu, Haidong
    Liu, Shen
    Zhang, Xiaonong
    Zheng, Yufeng
    Chai, Yimin
    [J]. BIOMATERIALS, 2016, 81 : 14 - 26
  • [9] In vitro and in vivo corrosion, cytocompatibility and mechanical properties of biodegradable Mg-Y-Ca-Zr alloys as implant materials
    Chou, Da-Tren
    Hong, Daeho
    Saha, Partha
    Ferrero, Jordan
    Lee, Boeun
    Tan, Zongqing
    Dong, Zhongyun
    Kumta, Prashant N.
    [J]. ACTA BIOMATERIALIA, 2013, 9 (10) : 8518 - 8533
  • [10] Evaluation of short-term effects of rare earth and other elements used in magnesium alloys on primary cells and cell lines
    Feyerabend, Frank
    Fischer, Janine
    Holtz, Jakob
    Witte, Frank
    Willumeit, Regine
    Druecker, Heiko
    Vogt, Carla
    Hort, Norbert
    [J]. ACTA BIOMATERIALIA, 2010, 6 (05) : 1834 - 1842