Sensitive and non-separation 5-hydroxymethylcytosine double-stranded DNA sensing in different mice tissues: Electrogenerated chemiluminescence biosensing method incorporating DNA nanomachine amplification and nanocomposite magnetic separation

被引:3
|
作者
Li, Sijia [1 ]
Zhang, Shengtao [1 ]
Shi, Jiayue [1 ]
Yang, Xia [1 ]
Sun, Huiping [2 ]
Li, Yan [1 ]
机构
[1] Northwest Univ, Coll Chem & Mat Sci, Key Lab Synthet & Nat Funct Mol Chem, Minist Educ, Xian 710069, Peoples R China
[2] Suzhou Univ Sci & Technol, Inst Mat Sci & Devices, Suzhou 215000, Peoples R China
基金
中国国家自然科学基金;
关键词
Electrogenerated chemiluminescence; 5-Hydroxymethylcytosine; DNA nanomachine; Nanocomposite magnetic separation; Mice tissue; NANOPARTICLES;
D O I
10.1016/j.snb.2022.132179
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Herein, a sensitive and non-separation electrogenerated chemiluminescence (ECL) biosensing method that combines poly (diallyl dimethyl ammonium chloride)/ferrosoferric oxide/molybdenum disulfide (PDDA/Fe3O4/ MoS2) nanocomposite with DNA nanomachine was developed to determine 5-hydroxymethylcytosine modified double-strand DNA (5-hmC-dsDNA). A positively charged and magnetic PDDA/Fe3O4/MoS2 nanocomposite was proposed, which can be used to fix negatively charged 5-hmC-dsDNA to overcome the steric resistance problem and is available for magnetic fields separation. In addition, the DNA nanomachine with three elements was fabricated: a DNA walking probe for signal amplification, an ECL reagent labeled S1 DNA (Ru-S1), 5-hmC antibody (Ab) for specifically recognizing 5-hmC modification. In the presence of 5-hmC-dsDNA, sandwich type conjugates were generated to incubate PDDA/Fe3O4/MoS2 and DNA nanomachine. After magnetic separation and the DNA walking driven by enzyme cleavage, a lot of ECL reagents were released and increased the ECL signal. ECL measurement was performed in a separation-free format. The method showed a broader linear range (0.0090-0.5761 %) and a low limit of detection (0.0024 %). Furthermore, the determination of 5-hmCdsDNA in different mice tissues using the ECL biosensing method was also carried out, demonstrating that the established strategy may pave a novel avenue for the early clinical diagnosis of disease.
引用
收藏
页数:8
相关论文
共 1 条
  • [1] Electrogenerated chemiluminescence biosensing method based on 5-hydroxymethylcytosine antibody and PDDA-CNTs nanocomposites for the determination of 5-hydroxymethylcytosine double-stranded DNA
    Meng, Yao
    Bai, Wanqiao
    Zhang, Yuling
    Sun, Huiping
    Li, Yan
    TALANTA, 2020, 210