Enabling the aqueous solution sensing of skin-conformable organic field-effect transistor using an amphiphilic molecule

被引:9
作者
Shi, Wei [1 ]
Li, Qingyuan [1 ]
Zhang, Yunpeng [1 ]
Liu, Kai [1 ]
Huang, Xin [1 ]
Yang, Xueli [1 ]
Ran, Yang [1 ]
Li, Yifan [1 ]
Guo, Yunlong [1 ]
Liu, Yunqi [1 ]
机构
[1] Chinese Acad Sci, Beijing Natl Lab Mol Sci, Key Lab Organ Solids, Inst Chem, Beijing 100190, Peoples R China
基金
中国国家自然科学基金; 国家重点研发计划;
关键词
Organic field-effect transistor; Flexible; Glucose; Aqueous; Sensor; RAMAN-SPECTROSCOPY; GLUCOSE; PENTACENE; ELECTRONICS; INTERFACE; WATER; AIR;
D O I
10.1016/j.apmt.2021.101275
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Research on aqueous solution sensor has immense demand in biological sensing applications. While traditional organic field-effect transistors (OFETs) have shown promising prospect in the field of sensing, their application in the aqueous solution sensing far lag behind since the aqueous environment strongly limits the organic materials to work. Here, we design, somewhat counterintuitively, an approach to increase the affinity of OFET to aqueous solution by adding amphiphilic molecule in the hydrophobic semiconductor. This method enables the aqueous solution sensing of the OFET through providing a good wettability between the OFET and the aqueous environment. Benefiting from this, the OFET can detect glucose aqueous solution in the human blood range (0.5-2 mg/mL) and the strongest response derived from the variation of mobility is as high as 5600% when applied 1 mg/mL glucose solution. Under a curvature radius of 7.5 mm, the OFET still maintains the sensitivity to glucose down to 0.5 mg/mL. The sensing performance is tunable through changing the amphiphilic molecule with different Hydrophile-Lipophile Balance value and introducing dielectric material in semiconductor. In addition, the selective detection to aqueous solutions of glucose, raffinose, starch, and lactic acid is realized. Portable real-time detection is achieved by integrating the OFET with wireless transmission and a smartphone. When the glucose concentration exceeds the limit, a red-light signal can be triggered as a warning. The work develops a simple approach for OFET to achieve aqueous solution detection.(c) 2021 Elsevier Ltd. All rights reserved.
引用
收藏
页数:10
相关论文
共 48 条
[1]   Influence of static electric field on Raman polarizability of optically trapped polystyrene beads [J].
Adarsh, U. K. ;
Bankapur, Aseefhali ;
Acharya, Mahendra ;
Chidangil, Santhosh .
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2020, 228
[2]   Carbon based materials for electronic bio-sensing [J].
Angione, Maria D. ;
Pilolli, Rosa ;
Cotrone, Serafina ;
Magliulo, Maria ;
Mallardi, Antonia ;
Palazzo, Gerardo ;
Sabbatini, Luigia ;
Fine, Daniel ;
Dodabalapur, Ananth ;
Cioffi, Nicola ;
Torsi, Luisa .
MATERIALS TODAY, 2011, 14 (09) :424-433
[3]  
[Anonymous], GLOBAL IMPACT DIABET
[4]   Modulation of the Coffee-Ring Effect in Particle/Surfactant Mixtures: the Importance of Particle-Interface Interactions [J].
Anyfantakis, Manos ;
Geng, Zheng ;
Morel, Mathieu ;
Rudiuk, Sergii ;
Baigl, Damien .
LANGMUIR, 2015, 31 (14) :4113-4120
[5]   Rapid, noninvasive concentration measurements of aqueous biological analytes by near-infrared Raman spectroscopy [J].
Berger, AJ ;
Wang, Y ;
Feld, MS .
APPLIED OPTICS, 1996, 35 (01) :209-212
[6]   Non-enzymatic glucose sensing by enhanced Raman spectroscopy on flexible 'as-grown' CVD graphene [J].
Chattopadhyay, Surojit ;
Li, Mau-Shiun ;
Roy, Pradip Kumar ;
Wu, C. T. .
ANALYST, 2015, 140 (12) :3935-3941
[7]   Electrocatalytic oxidation of glucose on bronze for monitoring of saliva glucose using a smart toothbrush [J].
Chen, Jian ;
Zhu, Xiaofei ;
Ju, Yinhui ;
Ma, Biao ;
Zhao, Chao ;
Liu, Hong .
SENSORS AND ACTUATORS B-CHEMICAL, 2019, 285 :56-61
[8]   Skin-like biosensor system via electrochemical channels for noninvasive blood glucose monitoring [J].
Chen, Yihao ;
Lu, Siyuan ;
Zhang, Shasha ;
Li, Yan ;
Qu, Zhe ;
Chen, Ying ;
Lu, Bingwei ;
Wang, Xinyan ;
Feng, Xue .
SCIENCE ADVANCES, 2017, 3 (12)
[9]   Selective Nonenzymatic Amperometric Detection of Lactic Acid in Human Sweat Utilizing a Multi-Walled Carbon Nanotube (MWCNT)-Polypyrrole Core-Shell Nanowire [J].
Choi, Young Min ;
Lim, Hana ;
Lee, Ho-Nyun ;
Park, Young Min ;
Park, Jin-Seong ;
Kim, Hyun-Jong .
BIOSENSORS-BASEL, 2020, 10 (09)
[10]   ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY [J].
CLARK, LC ;
LYONS, C .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1962, 102 (01) :29-&