Variability of radiation doses of cardiac diagnostic imaging tests: the RADIO-EVINCI study (RADIationdOse subproject of the EVINCI study)

被引:19
作者
Carpeggiani, Clara [1 ]
Picano, Eugenio [1 ]
Brambilla, Marco [2 ]
Michelassi, Claudio [1 ]
Knuuti, Juhani [3 ,4 ]
Kauffman, Philipp [5 ]
Underwood, S. Richard [6 ,7 ]
Neglia, Danilo [8 ]
机构
[1] CNR, Inst Clin Physiol, Via Moruzzi, I-56124 Pisa, Italy
[2] Univ Hosp Maggiore Carita, Dept Phys Med, Corso Mazzini 18, I-28100 Novara, Italy
[3] Univ Turku, Kinakvarngatan 4-8, Turku 20520, Finland
[4] Turku Univ Hosp, Kinakvarngatan 4-8, Turku 20520, Finland
[5] Univ Hosp Zurich, Ramistr 100, CH-8091 Zurich, Switzerland
[6] Imperial Coll London, Natl Heart & Lung Inst, London, England
[7] Royal Brompton & Harefield Hosp, Dept Nucl Med, Sydney St, London SW3 6NP, England
[8] Fdn Toscana G Monasterio, Via Moruzzi 1, Pisa, Italy
来源
BMC CARDIOVASCULAR DISORDERS | 2017年 / 17卷
关键词
Medical imaging; Radiation dose exposure; Effective dose; CT; EXPOSURE; ANGIOGRAPHY;
D O I
10.1186/s12872-017-0474-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Patients with coronary artery disease can accumulate significant radiation dose through repeated exposures to coronary computed tomographic angiography, myocardial perfusion imaging with single photon emission computed tomography or positron emission tomography, and to invasive coronary angiography. Aim of the study was to audit radiation doses of coronary computed tomographic angiography, single photon emission computed tomography, positron emission tomography and invasive coronary angiography in patients enrolled in the prospective, randomized, multi-centre European study-EVINCI (Evaluation of Integrated Cardiac Imaging for the Detection and Characterization of Ischemic Heart Disease). Methods: We reviewed 1070 tests (476 coronary computed tomographic angiographies, 85 positron emission tomographies, 310 single photon emission computed tomographies, 199 invasive coronary angiographies) performed in 476 patients (mean age 60 +/- 9 years, 60% males) enrolled in 12 centers of the EVINCI. The effective doses were calculated in milli-Sievert (mSv) as median, interquartile range (IQR) and coefficient of variation of the mean. Results: Coronary computed tomographic angiography (476 exams in 12 centers) median effective dose was 9. 6 mSv (IQR = 13.2 mSv); single photon emission computed tomography (310 exams in 9 centers) effective dose was 9.3 (IQR = 2.8); positron emission tomography (85 in 3 centers) effective dose 1.8 (IQR = 1.6) and invasive coronary angiography (199 in 9 centers) effective dose 7.4 (IQR = 7.3). Inter-institutional variability was highest for invasive coronary angiography (100%) and coronary computed tomographic angiography (54%) and lowest for single photon emission computed tomography (20%). Intra-institutional variability was highest for invasive coronary angiography (121%) and coronary computed tomographic angiography (115%) and lowest for single photon emission computed tomography (14%). Conclusion: Coronary computed tomographic angiography and invasive coronary angiography doses vary substantially between and within centers. The variability in nuclear medicine procedures is substantially lower. The findings highlight the need to audit doses, to track cumulative exposures and to standardize doses for imaging techniques.
引用
收藏
页数:8
相关论文
共 29 条
  • [11] Einstein AJ, 2013, JAMA INTERN MED, V173, P1021
  • [12] Radiation dose to patients from cardiac diagnostic imaging
    Einstein, Andrew J.
    Moser, Kevin W.
    Thompson, Randall C.
    Cerqueira, Manuel D.
    Henzlova, Milena J.
    [J]. CIRCULATION, 2007, 116 (11) : 1290 - 1305
  • [13] Current worldwide nuclear cardiology practices and radiation exposure: results from the 65 country IAEA Nuclear Cardiology Protocols Cross-Sectional Study (INCAPS)
    Einstein, Andrew J.
    Pascual, Thomas N. B.
    Mercuri, Mathew
    Karthikeyan, Ganesan
    Vitola, Joao V.
    Mahmarian, John J.
    Better, Nathan
    Bouyoucef, Salah E.
    Bom, Henry Hee-Seung
    Lele, Vikram
    Magboo, V. Peter C.
    Alexanderson, Erick
    Allam, Adel H.
    Al-Mallah, Mouaz H.
    Flotats, Albert
    Jerome, Scott
    Kaufmann, Philipp A.
    Luxenburg, Osnat
    Shaw, Leslee J.
    Underwood, S. Richard
    Rehani, Madan M.
    Kashyap, Ravi
    Paez, Diana
    Dondi, Maurizio
    Karthikeyan, G.
    Mercuri, M.
    Allam, A.
    Bom, H.
    Mahmarian, J.
    Vitola, J.
    Amouri, W.
    Essabbah, H.
    Gassama, S. S.
    Makhdomi, K. B.
    El Mustapha, G. I. E.
    El Ouchdi, N.
    Qais, N.
    Soni, N.
    Vangu, W.
    Abazid, R. M.
    Adams, B.
    Agarwal, V.
    Alfeeli, M. A.
    Alnafisi, N.
    Bernabe, L.
    Bural, G. G.
    Chaiwatanarat, T.
    Chandraguptha, J. M.
    Cheon, G. J.
    Cho, I.
    [J]. EUROPEAN HEART JOURNAL, 2015, 36 (26) : 1689 - 1696
  • [14] Effects of Radiation Exposure From Cardiac Imaging How Good Are the Data?
    Einstein, Andrew J.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (06) : 553 - 565
  • [15] The consequences of the economic crisis in radiology
    European Society of Radiology
    [J]. INSIGHTS INTO IMAGING, 2015, 6 (06): : 573 - 577
  • [16] Radiation exposure from radionuclide myocardial perfusion imaging: Concerns and solutions
    Fazel, Reza
    Shaw, Leslee J.
    [J]. JOURNAL OF NUCLEAR CARDIOLOGY, 2011, 18 (04) : 562 - 565
  • [17] Coronary computed tomography angiography with model-based iterative reconstruction using a radiation exposure similar to chest X-ray examination
    Fuchs, Tobias A.
    Stehli, Julia
    Bull, Sacha
    Dougoud, Svetlana
    Clerc, Olivier F.
    Herzog, Bernhard A.
    Buechel, Ronny R.
    Gaemperli, Oliver
    Kaufmann, Philipp A.
    [J]. EUROPEAN HEART JOURNAL, 2014, 35 (17) : 1131 - 1136
  • [18] Radiation Exposure to Patients in a Multicenter Coronary Angiography Trial (CORE 64)
    Geleijns, Jacob
    Joemai, Raoul M. S.
    Dewey, Marc
    de Roos, Albert
    Zankl, Maria
    Calzado Cantera, Alfonso
    Salvado Artells, Marcal
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 196 (05) : 1126 - 1132
  • [19] Hart D., 1994, Estimation of effective dose in diagnostic radiology from entrance surface dose and dose-area product measurements
  • [20] Practical ways to reduce radiation dose for patients and staff during device implantations and electrophysiological procedures
    Heidbuchel, Hein
    Wittkampf, Fred H. M.
    Vano, Eliseo
    Ernst, Sabine
    Schilling, Richard
    Picano, Eugenio
    Mont, Lluis
    [J]. EUROPACE, 2014, 16 (07): : 946 - 964