THE IDEALIZED AND THE REALISTIC VALIDATION STUDIES OF BUILDING SIMULATION MODELS IN GHANA

被引:0
作者
Koranteng, C. [1 ]
Simons, B. [2 ]
Gyimah, K. A. [1 ]
Amos-Abanyie, S. [1 ]
机构
[1] Kwame Nkrumah Univ Sci & Technol, Dept Architecture, Kumasi, Ghana
[2] Kwame Nkrumah Univ Sci & Technol, Dept Construct Technol & Management, Kumasi, Ghana
来源
JOURNAL OF GREEN BUILDING | 2022年 / 17卷 / 03期
关键词
validation; simulation; building performance; temperature; energy use; EMPIRICAL VALIDATION; ENERGY; PERFORMANCE;
D O I
10.3992/jgb.17.3.141
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The research is based on the premise that in order for a building energy model to contribute to a sustainable energy future, the model's accuracy must be ensured in order for the model's results to be trusted. Therefore, validation processes in continu-ing Ghanaian building performance studies are outlined. The process started with long-term monitoring of low-rise, multi-storey and test cells structures. Combined with weather data from meteorological offices, reliance on synthetic weather files and local measurements, appropriate matching periods of weather data and measure-ments were used to simulate indoor parameters. Further, the simulated and measured data were in good agreement in terms of regression values (r2 of 0.53-0.96). Energy use bills were used to validate energy loads of a multi-story building which resulted in a difference of 0.09% between the simulated and billed data. Furthermore, an approach of using the Coefficient of Variance for Root Mean Square Error (CV (RMSE)) was also presented. Considering the range of the regression values which could be due to the difficulty in the validating process; one can confidently rely on the outcome to predict building performance. Sampled challenges are the potential of synthetic weather files to overlook microclimatic conditions such as urban heat island effects; difficulty in predicting internal loads as comprehensive monitoring devices are lacking, e.g., occupancy sensors to monitor the actual number of people present at a time and their behaviour within spaces; system performance values which are known to decline with time, therefore, affecting measured versus simulated values; most firms not keeping energy bills and their unwillingness to provide the informa-tion to researchers; etc. The validated models can be used as scientific-based data and analysis to inform building designers decisions to reduce the economic and environmental burden in Ghana.
引用
收藏
页码:141 / 160
页数:20
相关论文
共 25 条
[1]  
Amos-Abanyie S., 2017, 6 INT C INFRASTRUCTU
[2]  
Buyak N.A., 2017, BUILDINGS ENERGY USE
[3]   Contrasting the capabilities of building energy performance simulation programs [J].
Crawley, Drury B. ;
Hand, Jon W. ;
Kurnmert, Michal ;
Griffith, Brent T. .
BUILDING AND ENVIRONMENT, 2008, 43 (04) :661-673
[4]  
Fukuda T., 2019, INDOOR THERMAL ENV D
[5]  
Gyimah K. A., 2019, THESIS KWAME NKRUMAH
[6]  
Hensen J.L.M., 1991, Ph.D. Thesis
[7]   User behavior in whole building simulation [J].
Hoes, P. ;
Hensen, J. L. M. ;
Loomans, M. G. L. C. ;
de Vries, B. ;
Bourgeois, D. .
ENERGY AND BUILDINGS, 2009, 41 (03) :295-302
[8]  
Kreider, 1994, ASHRAE T TECHNICAL P, V100, P56
[9]  
Li W., 2019, INDOOR THERMAL ENV O
[10]   An empirical validation of the daylighting algorithms and associated interactions in building energy simulation programs using various shading devices and windows [J].
Loutzenhiser, Peter G. ;
Maxwell, Gregory M. ;
Manz, Heinrich .
ENERGY, 2007, 32 (10) :1855-1870