Accurate measurement of three-dimensional knee replacement kinematics using single-plane fluoroscopy

被引:439
作者
Banks, SA
Hodge, WA
机构
[1] Orthopaedic Research Laboratory, Good Samaritan Medical Center, West Palm Beach, FL 33402
[2] Orthopaedic Research Laboratory, Good Samaritan Medical Center, West Palm Beach
关键词
D O I
10.1109/10.495283
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A simple extension of a previously reported object recognition technique has been used to implement a six-degree-of-freedom position/orientation estimator for the measurement of knee replacement motion from two-dimensional (2-D) fluoroscopic images. Computer modeling studies and controlled mechanical tests were performed to assess the accuracy of the technique. The results indicate that knee rotations can be measured with an accuracy of approximately one degree and that sagittal plane translations can be measured with an accuracy of approximately 0.5 mm. The measurement technique is uniquely well suited for performing dynamic kinematic measurements on individuals with knee replacements, and for performing comparative studies among subjects with different designs of knee replacements.
引用
收藏
页码:638 / 649
页数:12
相关论文
共 44 条