Contour scanning for penumbra improvement in pencil beam scanned proton therapy

被引:22
作者
Meier, G. [1 ,2 ]
Leiser, D. [3 ,4 ]
Besson, R. [1 ]
Mayor, A. [1 ]
Safai, S. [1 ]
Weber, D. C. [1 ,3 ,4 ,5 ]
Lomax, A. J. [1 ,2 ]
机构
[1] Paul Scherrer Inst, Ctr Proton Therapy, Villigen, Switzerland
[2] Swiss Fed Inst Technol, Zurich, Switzerland
[3] Univ Hosp Bern, Inselspital, Dept Radiat Oncol, CH-3010 Bern, Switzerland
[4] Univ Bern, Bern, Switzerland
[5] Univ Zurich, Zurich, Switzerland
关键词
proton therapy; pencil beam scanning; scanning patterns; PAUL-SCHERRER-INSTITUTE; RADIATION-THERAPY; SKULL-BASE; SPOT SIZE; DELIVERY; CHONDROSARCOMA; CHORDOMA; RECONSTRUCTION; VERIFICATION; RADIOTHERAPY;
D O I
10.1088/1361-6560/aa5dde
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Proton therapy, especially in the form of pencil beam scanning (PBS), allows for the delivery of highly conformal dose distributions for complex tumor geometries. However, due to scattering of protons inside the patient, lateral dose gradients cannot be arbitrarily steep, which is of importance in cases with organs at risk (OARs) in close proximity to, or overlapping with, planning target volumes (PTVs). In the PBS approach, physical pencil beams are planned using a regular grid orthogonal to the beam direction. In this work, we propose an alternative to this commonly used approach where pencil beams are placed on an irregular grid along concentric paths based on the target contour. Contour driven pencil beam placement is expected to improve dose confirmation by allowing the optimizer to best enhance the penumbra of irregularly shaped targets using edge enhancement. Its effectiveness has been shown to improve dose confirmation to the target volume and reduce doses to OARs in head-and-neck planning studies. Furthermore, the deliverability of such plans, as well as the dosimetric improvements over conventional grid-based plans, have been confirmed in first phantom based verifications.
引用
收藏
页码:2398 / 2416
页数:19
相关论文
共 31 条
[1]   Experimental verification of IMPT treatment plans in an anthropomorphic phantom in the presence of delivery uncertainties [J].
Albertini, F. ;
Casiraghi, M. ;
Lorentini, S. ;
Rombi, B. ;
Lomax, A. J. .
PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (14) :4415-4431
[2]   The influence of the optimization starting conditions on the robustness of intensity-modulated proton therapy plans [J].
Albertini, F. ;
Hug, E. B. ;
Lomax, A. J. .
PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (10) :2863-2878
[3]   Pencil beam scanning proton therapy for pediatric intracranial ependymoma [J].
Ares, Carmen ;
Albertini, Francesca ;
Frei-Welte, Martina ;
Bolsi, Alessandra ;
Grotzer, Michael A. ;
Goitein, Gudrun ;
Weber, Damien C. .
JOURNAL OF NEURO-ONCOLOGY, 2016, 128 (01) :137-145
[4]   EFFECTIVENESS AND SAFETY OF SPOT SCANNING PROTON RADIATION THERAPY FOR CHORDOMAS AND CHONDROSARCOMAS OF THE SKULL BASE: FIRST LONG-TERM REPORT [J].
Ares, Carmen ;
Hug, Eugen B. ;
Lomax, Antony J. ;
Bolsi, Alessandra ;
Timmermann, Beate ;
Rutz, Hans Peter ;
Schuller, Jan C. ;
Pedroni, Eros ;
Goitein, Gudrun .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (04) :1111-1118
[5]   Performance of a fluorescent screen and CCD camera as a two-dimensional dosimetry system for dynamic treatment techniques [J].
Boon, SN ;
van Luijk, P ;
Böhringer, T ;
Coray, A ;
Lomax, A ;
Pedroni, E ;
Schaffner, B ;
Schippers, JM .
MEDICAL PHYSICS, 2000, 27 (10) :2198-2208
[6]   Development and Clinical Implementation of a Universal Bolus to Maintain Spot Size During Delivery of Base of Skull Pencil Beam Scanning Proton Therapy [J].
Both, Stefan ;
Shen, Jiajian ;
Kirk, Maura ;
Lin, Liyong ;
Tang, Shikui ;
Alonso-Basanta, Michelle ;
Lustig, Robert ;
Lin, Haibo ;
Deville, Curtiland ;
Hill-Kayser, Christine ;
Tochner, Zelig ;
McDonough, James .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 (01) :79-84
[7]   OPTIMAL SURFACE RECONSTRUCTION FROM PLANAR CONTOURS [J].
FUCHS, H ;
KEDEM, ZM ;
USELTON, SP .
COMMUNICATIONS OF THE ACM, 1977, 20 (10) :693-702
[8]  
Koehler A M, 1977, NUCL INSTRUM METHODS, V4, P297
[9]   Comparing proton treatment plans of pediatric brain tumors in two pencil beam scanning nozzles with different spot sizes [J].
Kralik, John C. ;
Xi, Liwen ;
Solberg, Timothy D. ;
Simone, Charles B., II ;
Lin, Liyong .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (06) :41-50
[10]   RADIATION DOSE-VOLUME EFFECTS IN THE BRAIN [J].
Lawrence, Yaacov Richard ;
Li, X. Allen ;
el Naqa, Issam ;
Hahn, Carol A. ;
Marks, Lawrence B. ;
Merchant, Thomas E. ;
Dicker, Adam P. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 76 (03) :S20-S27