共 55 条
Quality of Life in the Tube Versus Trabeculectomy Study
被引:37
作者:
Kotecha, Aachal
[1
,2
]
Feuer, William J.
[3
]
Barton, Keith
[1
,2
]
Gedde, Steven J.
[3
]
机构:
[1] Moorfields Eye Hosp NHS Fdn Trust, NIHR Biomed Res Ctr Ophthalmol, London, England
[2] UCL Inst Ophthalmol, London, England
[3] Univ Miami, Miller Sch Med, Bascom Palmer Eye Inst, Miami, FL 33136 USA
基金:
美国国家卫生研究院;
关键词:
COLLABORATIVE INITIAL GLAUCOMA;
MINIMALLY IMPORTANT DIFFERENCES;
VISUAL-FIELD LOSS;
BASE-LINE CHARACTERISTICS;
REPORTED OUTCOME MEASURES;
INTRAOCULAR-PRESSURE;
LONGITUDINAL CHANGES;
HEALTH-STATUS;
END-POINTS;
DESIGN;
D O I:
10.1016/j.ajo.2017.01.019
中图分类号:
R77 [眼科学];
学科分类号:
100212 ;
摘要:
PURPOSE: To report the vision-specific quality-of-life (QoL) outcomes in the Tube Versus Trabeculectomy (TVT) Study. DESIGN: Multicenter randomized clinical trial. METHODS: SETTING: Seventeen clinical centers. STUDY POPULATION: Patients 18-85 years of age with medically uncontrolled glaucoma who had previous cataract and/or glaucoma surgery. INTERVENTIONS: Tube shunt (350-mm(2) Baerveldt glaucoma implant) or trabeculectomy with MMC. MAIN OUTCOME MEASURES: Vision specific QoL using the NEI VFQ-25 and estimation of minimally important differences (MID) were the main outcome measures. Cross-sectional distribution- and anchor-based approaches were used to estimate MID. Clinical anchor measures included the mean deviation (MD) and logMAR visual acuity (VA) measurements. Clinically significant changes in anchor were defined as >= 2 dB MD and >= 0.2 logMAR. RESULTS: No significant differences in composite scores were observed between treatment groups, and no significant change in scores were seen over time. Mean (SD; range) values of clinical anchors at baseline were 16.6 (9.3; -32 to -0.5) dB for the surgical eye and 0.2 (0.3; -0.1 to 1.3) logMAR VA in the better-vision eye. For anchor-based cross-sectional analysis, composite score MID (95% CI) was 6.3 (4.6-7.9) for better-eye VA and 1.4 (0.9-1.9) for surgical eye MD. Distribution-based MID for the composite score was 6.0. CONCLUSIONS: Trabeculectomy and tube shunt surgery had similar impact on patient-reported vision-specific QoL measured using the NEI VFQ-25. In this cohort of patients with advanced glaucoma, MIDs varied depending on the clinical anchor used. Distribution-based MIDs corresponded well with anchor-based MIDs based on VA measures. The MID values reported here may be useful for others wishing to interpret NEI VFQ-25 scores in their advanced glaucoma patient cohort. (C) 2017 Elsevier Inc. All rights reserved.
引用
收藏
页码:228 / 235
页数:8
相关论文