An innovative CCD-based high-resolution CT system for analysis of trabecular bone tissue

被引:10
作者
Baruffaldi, F. [1 ]
Beituzzi, M.
Bianconi, D.
Brancaccio, R.
Cornacchia, S.
Lanconelli, N.
Mancini, L.
Morigi, M. P.
Pasini, A.
Perilli, E.
Romani, D.
Rossi, A.
Casali, E.
机构
[1] Ist Ortoped Rizzoli, Lab Tecnol Med, I-40136 Bologna, Italy
[2] Univ Bologna, Dept Phys, I-40127 Bologna, Italy
[3] Ist Nazl Fis Nucl, I-40127 Bologna, Italy
[4] Trieste SCpA, I-34012 Trieste, Italy
[5] Univ Bologna, Dept Elect Comp Sci & Syst, I-40136 Bologna, Italy
关键词
biomedical; X-ray detectors; X-ray tomography;
D O I
10.1109/TNS.2006.876047
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Synchrotron-based digital radiography and microtomography devices are powerful, nondestructive, high-resolution research tools. In this paper, we present a linear system with a pixel size of 22.5 mu m and a field-of-view (FOV) 13 cm long and about 1 mm high. The system is composed of a linear converter GOS screen coupled to an intensified electron-bombarded CCD (EBCCD) camera, by means of a rectangular-to-linear fiber optic adapter. This optical guide is composed of seven bundles, each one transporting light in a coherent way to preserve spatial information. In this way, a high spatial resolution over an extended FOV is obtained. The detector works as an X-ray scanner by means of a high-precision translation mechanical device with 18 cm travel range. The total FOV obtained this way is 13 cm long and 18 cm high. The aim of this paper is to demonstrate the feasibility of this system to investigate a large area of a bone and to calculate the appropriate histomorphometric parameters. Here we present an investigation gained at ELETTRA synchrotron facility at Trieste, Italy. A monochromatic 34-keV beam has been used for imaging a human proximal femur, about 9 cm in width, with our system. The reconstructed images (13 cm x 13 cm) were cross sections containing femoral head, femoral neck, and greater trochanter. The local variations in trabecular and cortical structure of the examined bone were clearly visible at a level not obtainable with medical CT scanners. The used spatial resolution allowed the visualization of thin trabeculae, which typically lie in a range of 100 mu m or lower. The quality of the reconstructed cross-section images confirmed that the system presented is a novel tool for high resolution three-dimensional (3-D) imaging of bone structure, with a pixel size over a volume of interest not achievable with conventional microCT scanners.
引用
收藏
页码:2584 / 2590
页数:7
相关论文
共 34 条
[1]  
Aaron JE, 2000, BONE, V27, P277, DOI 10.1016/S8756-3282(00)00328-8
[2]  
[Anonymous], 2001, P SPIE
[3]   Age-related changes in the biochemical properties of human cancellous bone collagen: Relationship to bone strength [J].
Bailey, AJ ;
Sims, TJ ;
Ebbesen, EN ;
Mansell, JP ;
Thomsen, JS ;
Mosekilde, L .
CALCIFIED TISSUE INTERNATIONAL, 1999, 65 (03) :203-210
[4]   A new linear array detector for high resolution and low dose digital radiography [J].
Bettuzzi, M ;
Cornacchia, S ;
Rossi, M ;
Paltrinieri, E ;
Morigi, MP ;
Brancaccio, R ;
Romani, D ;
Casali, F .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2004, 213 :227-230
[5]   An in vitro study of the ultrasonic axial transmission technique at the radius: 1-MHz velocity measurements are sensitive to both mineralization and intracortical porosity [J].
Bossy, E ;
Talmant, M ;
Peyrin, F ;
Akrout, L ;
Cloetens, P ;
Laugier, P .
JOURNAL OF BONE AND MINERAL RESEARCH, 2004, 19 (09) :1548-1556
[6]   Bone microdamage acid skeletal fragility in osteoporotic and stress fractures [J].
Burr, DB ;
Forwood, MR ;
Fyhrie, DP ;
Martin, B ;
Schaffler, MB ;
Turner, CH .
JOURNAL OF BONE AND MINERAL RESEARCH, 1997, 12 (01) :6-15
[7]   High-resolution computed tomography for architectural characterization of human lumbar cancellous bone: Relationships with histomorphometry and biomechanics [J].
Cendre, E ;
Mitton, D ;
Roux, JP ;
Arlot, ME ;
Duboeuf, F ;
Burt-Pichat, B ;
Rumelhart, C ;
Peix, G ;
Meunier, PJ .
OSTEOPOROSIS INTERNATIONAL, 1999, 10 (05) :353-360
[8]   EVALUATION OF ORTHOGONAL MECHANICAL-PROPERTIES AND DENSITY OF HUMAN TRABECULAR BONE FROM THE MAJOR METAPHYSEAL REGIONS WITH MATERIALS TESTING AND COMPUTED-TOMOGRAPHY [J].
CIARELLI, MJ ;
GOLDSTEIN, SA ;
KUHN, JL ;
CODY, DD ;
BROWN, MB .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1991, 9 (05) :674-682
[9]   Variations in three-dimensional cancellous bone architecture of the proximal femur in female hip fractures and in controls [J].
Ciarelli, TE ;
Fyhrie, DP ;
Schaffler, MB ;
Goldstein, SA .
JOURNAL OF BONE AND MINERAL RESEARCH, 2000, 15 (01) :32-40
[10]   Relationship between computed tomographic image analysis and histomorphometry for microarchitectural characterization of human calcaneus [J].
Cortet, B ;
Chappard, D ;
Boutry, N ;
Dubois, P ;
Cotten, A ;
Marchandise, X .
CALCIFIED TISSUE INTERNATIONAL, 2004, 75 (01) :23-31