Photon Counting Energy Dispersive Detector Arrays for X-ray Imaging

被引:242
作者
Iwanczyk, Jan S. [1 ]
Nygard, Einar [1 ,2 ]
Meirav, Oded [3 ]
Arenson, Jerry [3 ]
Barber, William C. [1 ]
Hartsough, Neal E. [1 ]
Malakhov, Nail [1 ,2 ]
Wessel, Jan C. [1 ,2 ]
机构
[1] DxRay Inc, Northridge, CA 91324 USA
[2] Interon AS, Asken, Norway
[3] GE Global Res, Haifa, Israel
基金
美国国家卫生研究院;
关键词
CdTe; CdZnTe; photon counting computed tomography; X-ray detectors; COMPUTED-TOMOGRAPHY; READOUT; CDTE;
D O I
10.1109/TNS.2009.2013709
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The development of an innovative detector technology for photon-counting in X-ray imaging is reported. This new generation of detectors, based on pixellated cadmium telluride (CdTe) and cadmium zinc telluride (CZT) detector arrays electrically connected to application specific integrated circuits (ASICs) for readout, will produce fast and highly efficient photon-counting and energy-dispersive X-ray imaging. There are a number of applications that can greatly benefit from these novel imagers including mammography, planar radiography, and computed tomography (CT). Systems based on this new detector technology can provide compositional analysis of tissue through spectroscopic X-ray imaging, significantly improve overall image quality, and may significantly reduce X-ray dose to the patient. A very high X-ray flux is utilized in many of these applications. For example, CT scanners can produce similar to 100 Mphotons/mm(2)/s in the unattenuated beam. High flux is required in order to collect sufficient photon statistics in the measurement of the transmitted flux (attenuated beam) during the very short time frame of a CT scan. This high count rate combined with a need for high detection efficiency requires the development of detector structures that can provide a response signal much faster than the transit time of carriers over the whole detector thickness. We have developed CdTe and CZT detector array structures which are 3 mm thick with 16 x 16 pixels and a 1 mm pixel pitch. These structures, in the two different implementations presented here, utilize either a small pixel effect or a drift phenomenon. An energy resolution of 4.75% at 122 keV has been obtained with a 30 ns peaking time using discrete electronics and a Co-57 source. An output rate of 6 X 10(6) counts per second per individual pixel has been obtained with our ASIC readout electronics and a clinical CT X-ray tube. Additionally, the first clinical CT images, taken with several of our prototype photon-counting and energy-dispersive detector modules, are shown.
引用
收藏
页码:535 / 542
页数:8
相关论文
共 28 条
  • [1] A System for the Characterization and Testing of CdZnTe/CdTe Pixel Detectors for X-ray and Gamma-ray Imaging
    Arodzero, Anatoli
    Barber, William C.
    Damron, Matthew Q.
    Hartsough, Neal E.
    Iwanczyk, Jan S.
    Malakhov, Nail
    Nygard, Einar
    Moraes, Danielle
    Weilhammer, Peter
    Jarron, Pierre
    [J]. 2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 3638 - 3642
  • [2] Barber WC, 2006, IEEE NUCL SCI CONF R, P2414
  • [3] A multimode digital detector readout for solid-state medical imaging detectors
    Boles, CD
    Boser, BE
    Hasegawa, BH
    Heanue, JA
    [J]. IEEE JOURNAL OF SOLID-STATE CIRCUITS, 1998, 33 (05) : 733 - 742
  • [4] First experimental tests with a CdTe photon counting pixel detector hybridized with a Medipix2 readout chip
    Chmeissani, M
    Frojdh, C
    Gal, O
    Llopart, X
    Ludwig, J
    Maiorino, M
    Manach, E
    Mettivier, G
    Montesi, MC
    Ponchut, C
    Russo, P
    Tlustos, L
    Zwerger, A
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (05) : 2379 - 2385
  • [5] ASIC with multiple energy discrimination for high-rate photon counting applications
    De Geronimo, Gianluigi
    Dragone, Angelo
    Grosholz, Joe
    O'Connor, Paul
    Vernon, Emerson
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2007, 54 (02) : 303 - 312
  • [6] HOFFMAN DM, 2005, Patent No. 6953935
  • [7] Hsieh J, 2003, COMPUT TOMOGR, DOI DOI 10.1117/3.2197756
  • [8] Simulation and modelling of a new silicon X-ray drift detector design for synchrotron radiation applications
    Iwanczyk, JS
    Patt, BE
    Segal, J
    Plummer, J
    Vilkelis, G
    Hedman, B
    Hodgson, KO
    Cox, AD
    Rehn, L
    Metz, J
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 380 (1-2) : 288 - 294
  • [9] IWANCZYK JS, 2007, Patent No. 7170049
  • [10] A transimpedance amplifier using a novel current mode feedback loop
    Jarron, P
    Anghinolfi, F
    Delagne, E
    Dabrowski, W
    Scharfetter, L
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 377 (2-3) : 435 - 439