Predictors of intra-aortic balloon pump hemodynamic failure in non-acute myocardial infarction cardiogenic shock

被引:34
|
作者
Hsu, Steven [1 ]
Kambhampati, Swetha [1 ]
Sciortino, Christopher M. [2 ]
Russell, Stuart D. [1 ]
Schulman, Steven P. [1 ]
机构
[1] Johns Hopkins Univ, Sch Med, Dept Med, Div Cardiol, Baltimore, MD 21205 USA
[2] Univ Pittsburgh, Dept Surg, Med Ctr, Div Cardiothorac Surg, Pittsburgh, PA USA
基金
美国国家卫生研究院;
关键词
MECHANICAL CIRCULATORY SUPPORT; VENTRICULAR ASSIST DEVICE; CHRONIC HEART-FAILURE; CARDIAC POWER; COUNTERPULSATION; TRIAL; SURVIVAL; INDEX;
D O I
10.1016/j.ahj.2017.11.016
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives To characterize patient profile and hemodynamic profile of those undergoing intra-aortic balloon pump (IABP) for cardiogenic shock and define predictors of hemodynamic failure of IABP support. Background Clinical characteristics of IABP support in cardiogenic shock not related to acute myocardial infarction (AMI) remain poorly characterized. Methods We retrospectively studied a cohort of 74 patients from 2010 to 2015 who underwent IABP insertion for cardiogenic shock complicating acute decompensated heart failure not due to AMI. Results In the overall cohort, which consisted primarily of patients with chronic systolic heart failure (89%), IABP significantly augmented cardiac index and lowered systemic vascular resistance (P < .05). Despite this improvement, 28% of these patients died (24%) or require urgent escalation in mechanical circulatory support (MCS) (4%). Multivariable regression revealed that baseline left ventricular cardiac power index (LVCPI), a measure of LV power output derived from cardiac index and mean arterial pressure (P = .01), and history of ischemic cardiomyopathy (P = .003) were significantly associated with the composite adverse-event endpoint of death or urgent MCS escalation. An IABP Failure risk score using baseline LVCPI <0.28 W/m(2) and ischemic history predicted 28-day adverse events with excellent discrimination. Conclusion Despite hemodynamic improvements with IABP support, patients with non-AMI cardiogenic shock still suffer poor outcomes. Patients with ischemic cardiomyopathy and low LVPCI fared significantly worse. These patients may warrant closer observation or earlier consideration of more advanced hemodynamic support.
引用
收藏
页码:181 / 191
页数:11
相关论文
共 50 条
  • [1] Letter to the editor regarding the results of the retrospective study "Predictors of intra-aortic balloon pump hemodynamic failure in non-acute myocardial infarction cardiogenic shock" published in the American Heart Journal
    Sacco, Alice
    Morici, Nuccia
    Oliva, Fabrizio
    AMERICAN HEART JOURNAL, 2019, 213 : 123 - 123
  • [2] Response to the letter to the editor regarding the results of the retrospective study "Predictors of intra-aortic balloon pump hemodynamic failure in non-acute myocardial infarction cardiogenic shock" published in the American Heart Journal
    Hsu, Steven
    AMERICAN HEART JOURNAL, 2019, 213 : 124 - 125
  • [3] PERCUTANEOUS MICROAXIAL VENTRICULAR ASSIST DEVICE VS. INTRA-AORTIC BALLOON PUMP FOR NON-ACUTE MYOCARDIAL INFARCTION CARDIOGENIC SHOCK
    Watanabe, Atsuyuki
    Miyamoto, Yoshihisa
    Ueyama, Hiroki
    Gotanda, Hiroshi
    Tsugawa, Yusuke
    Kuno, Toshiki
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2024, 83 (13) : 454 - 454
  • [4] The use of an intra-aortic balloon pump in patients with cardiogenic shock secondary to acute myocardial infarction
    Qutub, Mohammed A.
    CARDIOTHORACIC SURGEON, 2025, 33 (01):
  • [5] Predictors of Hemodynamic Response to Intra-Aortic Balloon Pump Therapy in Patients With Acute Decompensated Heart Failure and Cardiogenic Shock
    Huang, Athena L.
    Fried, Justin A.
    Malick, Waqas
    Topkara, Veli
    DeFilippis, Ersilia M.
    Haythe, Jennifer
    Farr, Maryjane
    Yuzefpolskaya, Melana
    Colombo, Paolo C.
    Takeda, Koji
    Grandin, E. Wilson
    Kirtane, Ajay J.
    Pinto, Duane
    Garan, A. Reshad
    JOURNAL OF INVASIVE CARDIOLOGY, 2021, 33 (04): : E275 - E280
  • [6] Predictors of Hemodynamic Response to Intra-Aortic Balloon Pump Therapy in Patients with Acute Decompensated Heart Failure and Cardiogenic Shock
    Huang, Athena L.
    Fried, Justin A.
    Malick, Waqas
    Topkara, Veli
    Griffin, Jan
    Clerkin, Kevin
    DeFilippis, Ersilia M.
    Farr, Maryjane
    Haythe, Jennifer
    Yuzefpolskaya, Melana
    Colombo, Paolo C.
    Takeda, Koji
    Garan, A. Reshad
    JOURNAL OF CARDIAC FAILURE, 2019, 25 (08) : S176 - S177
  • [7] Predictors of Hemodynamic Stabilization Following Intra-Aortic Balloon Pump Implantation for Cardiogenic Shock
    Juricek, C.
    Imamura, T.
    Costantini, H.
    Kagan, V.
    Song, T.
    Onsager, D.
    Ota, T.
    Adatya, S.
    Kim, G.
    Sarswat, N.
    Sayer, G.
    Jeevanandam, V.
    Uriel, N.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2017, 36 (04): : S117 - S117
  • [8] HEMODYNAMIC PREDICTORS OF SURVIVAL DURING INTRA-AORTIC BALLOON PUMP (IABP) IN MYOCARDIAL-INFARCTION SHOCK
    BOLOOKI, H
    MAYORGACORTES, A
    FRIED, A
    CLINICAL RESEARCH, 1976, 24 (03): : A210 - A210
  • [9] Intra-Aortic Balloon Counterpulsation in Acute Myocardial Infarction Complicated by Cardiogenic Shock
    Macas, Andrius
    Bukauskas, Tomas
    Suskeviciene, Ilona
    Baksyte, Giedre
    Pieteris, Linas
    Tamosiunas, Tomas
    Mundinaite, Audra
    Zaliunas, Remigijus
    MEDICINA-LITHUANIA, 2011, 47 (04): : 212 - 218
  • [10] Usefulness of Intra-Aortic Balloon Pump Counterpulsation in Patients With Cardiogenic Shock from Acute Myocardial Infarction
    Cheng, Jin M.
    Valk, Suzanne D. A.
    den Uil, Corstiaan A.
    van der Ent, Martin
    Lagrand, Wim K.
    van de Sande, Meike
    von Domburg, Ron T.
    Simoons, Maarten L.
    AMERICAN JOURNAL OF CARDIOLOGY, 2009, 104 (03): : 327 - 332