Differentiation of benign and malignant breast tumors by in-vivo three-dimensional parallel-plate diffuse optical tomography

被引:178
作者
Choe, Regine [1 ]
Konecky, Soren D. [1 ]
Corlu, Alper [1 ]
Lee, Kijoon [1 ,2 ]
Durduran, Turgut [1 ,3 ]
Busch, David R. [1 ]
Pathak, Saurav [1 ]
Czerniecki, Brian J. [4 ]
Tchou, Julia [4 ]
Fraker, Douglas L. [4 ]
DeMichele, Angela [5 ]
Chance, Britton [6 ]
Arridge, Simon R. [7 ]
Schweiger, Martin [7 ]
Culver, Joseph P. [1 ,8 ]
Schnall, Mitchell D. [3 ]
Putt, Mary E. [9 ]
Rosen, Mark A. [3 ]
Yodh, Arjun G. [1 ]
机构
[1] Univ Penn, Dept Phys & Astron, Philadelphia, PA 19104 USA
[2] Nanyang Technol Univ, Sch Chem & Biomed Engn, Div Bioengn, Singapore 637457, Singapore
[3] Hosp Univ Penn, Dept Radiol, Philadelphia, PA 19104 USA
[4] Hosp Univ Penn, Dept Surg, Philadelphia, PA 19104 USA
[5] Hosp Univ Penn, Dept Med Hematol Oncol, Philadelphia, PA 19104 USA
[6] Univ Penn, Dept Biochem & Biophys, Philadelphia, PA 19104 USA
[7] UCL, Dept Comp Sci, London WC1E 6BT, England
[8] Washington Univ, Sch Med, Dept Radiol, Mallinckrodt Inst Radiol, St Louis, MO 63110 USA
[9] Univ Penn, Dept Biostat & Epidemiol, Philadelphia, PA 19104 USA
关键词
breast cancer; diffuse optical tomography; near-infrared light; photon migration; optical mammography; NEAR-INFRARED TOMOGRAPHY; MONITORING NEOADJUVANT CHEMOTHERAPY; FALSE-NEGATIVE MAMMOGRAPHY; FREQUENCY-DOMAIN; FEMALE BREAST; ULTRASOUND LOCALIZATION; WAVELENGTH OPTIMIZATION; OXYGEN-SATURATION; CANCER DETECTION; TISSUE;
D O I
10.1117/1.3103325
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We have developed a novel parallel-plate diffuse optical tomography (DOT) system for three-dimensional in vivo imaging of human breast tumor based on large optical data sets. Images of oxy-, deoxy-, and total hemoglobin concentration as well as blood oxygen saturation and tissue scattering were reconstructed. Tumor margins were derived using the optical data with guidance from radiology reports and magnetic resonance imaging. Tumor-to-normal ratios of these endogenous physiological parameters and an optical index were computed for 51 biopsy-proven lesions from 47 subjects. Malignant cancers (N=41) showed statistically significant higher total hemoglobin, oxy- hemoglobin concentration, and scattering compared to normal tissue. Furthermore, malignant lesions exhibited a twofold average increase in optical index. The influence of core biopsy on DOT results was also explored; the difference between the malignant group measured before core biopsy and the group measured more than 1 week after core biopsy was not significant. Benign tumors (N=10) did not exhibit statistical significance in the tumor-to-normal ratios of any parameter. Optical index and tumor-to-normal ratios of total hemoglobin, oxy-hemoglobin concentration, and scattering exhibited high area under the receiver operating characteristic curve values from 0.90 to 0.99, suggesting good discriminatory power. The data demonstrate that benign and malignant lesions can be distinguished by quantitative three-dimensional DOT. (C) 2009 Society of Photo-Optical Instrumentation Engineers. [DOI: 10.1117/1.3103325]
引用
收藏
页数:18
相关论文
共 102 条
[1]  
[Anonymous], 2007, R LANG ENV STAT COMP
[2]  
[Anonymous], SEER Cancer Statistics Review, 1975-2001
[3]   A gradient-based optimisation scheme for optical tomography [J].
Arridge, SR ;
Schweiger, M .
OPTICS EXPRESS, 1998, 2 (06) :213-226
[4]   PHOTON-MEASUREMENT DENSITY-FUNCTIONS .2. FINITE-ELEMENT-METHOD CALCULATIONS [J].
ARRIDGE, SR ;
SCHWEIGER, M .
APPLIED OPTICS, 1995, 34 (34) :8026-8037
[5]   Standardized platform for coregistration of nonconcurrent diffuse optical and magnetic resonance breast images obtained in different geometries [J].
Azar, Fred S. ;
Lee, Kijoon ;
Khamene, Ali ;
Choe, Regine ;
Corlu, Alper ;
Konecky, Soren D. ;
Sauer, Frank ;
Yodh, Arjun G. .
JOURNAL OF BIOMEDICAL OPTICS, 2007, 12 (05)
[6]  
Bates D., 2009, Mixed-Effects Models in S and S-PLUS
[7]   Broadband absorption spectroscopy in turbid media by combined frequency-domain and steady-state methods [J].
Bevilacqua, F ;
Berger, AJ ;
Cerussi, AE ;
Jakubowski, D ;
Tromberg, BJ .
APPLIED OPTICS, 2000, 39 (34) :6498-6507
[8]   Mammographic characteristics of 115 missed cancers later detected with screening mammography and the potential utility of computer-aided detection [J].
Birdwell, RL ;
Ikeda, DM ;
O'Shaughnessy, KF ;
Sickles, EA .
RADIOLOGY, 2001, 219 (01) :192-202
[9]  
Bombardieri E, 2001, Q J NUCL MED, V45, P245
[10]   Spatio-temporal imaging of the hemoglobin in the compressed breast with diffuse optical tomography [J].
Boverman, Gregory ;
Fang, Qianqian ;
Carp, Stefan A. ;
Miller, Eric L. ;
Brooks, Dana H. ;
Selb, Juliette ;
Moore, Richard H. ;
Kopans, Daniel B. ;
Boas, David A. .
PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (12) :3619-3641