CFD based performance analysis of a solar air heater duct provided with artificial roughness

被引:172
作者
Kumar, Sharad [1 ]
Saini, R. P. [1 ]
机构
[1] Indian Inst Technol, Alternate Hydro Energy Ctr, Roorkee 247667, Uttar Pradesh, India
关键词
Solar air heater; Artificial roughness; CFD; Heat transfer; Friction; Turbulence; FRICTION FACTOR CORRELATIONS; OPTIMAL THERMOHYDRAULIC PERFORMANCE; SHAPED RIB ROUGHNESS; ABSORBER PLATE; TRANSFER COEFFICIENT; RECTANGULAR DUCTS; FLOW; TRANSVERSE; PASSAGES;
D O I
10.1016/j.renene.2008.09.015
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In the present work the performance of a solar air heater duct provided with artificial roughness in the form of thin circular wire in arc shaped geometry has been analysed using Computational Fluid Dynamics (CFD). The effect of arc shaped geometry on heat transfer coefficient, friction factor and performance enhancement was investigated covering the range of roughness parameter (relative roughness height (e/D) from 0.0299 to 0.0426 and relative roughness angle (alpha/90) from 0.333 to 0.666) and working parameter (Reynolds number, Re from 6000 to 18,000 and solar radiation of 1000 W/m2). Different turbulent models have been used for the analysis and their results are compared. Renormalization-group (RNG) k-epsilon model based results have been found in good agreement and accordingly this model is used to predict heat transfer and friction factor in the duct. The overall enhancement ratio has been calculated in order to discuss the overall effect of the roughness and working parameters. A maximum value of overall enhancement ratio has been found to be as 1.7 for the range of parameters investigated. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1285 / 1291
页数:7
相关论文
共 28 条
[1]  
*AM SOC HEAT REFR, 1977, 9377 ASHARE INC
[2]   Heat transfer coefficient and friction factor correlations for rectangular solar air heater duct having transverse wedge shaped rib roughness on the absorber plate [J].
Bhagoria, JL ;
Saini, JS ;
Solanki, SC .
RENEWABLE ENERGY, 2002, 25 (03) :341-369
[3]   Analysis of heat transfer augmentation and flow characteristics due to rib roughness over absorber plate of a solar air heater [J].
Chaube, A ;
Sahoo, PK ;
Solanki, SC .
RENEWABLE ENERGY, 2006, 31 (03) :317-331
[4]  
CHAUDHURY, 1988, SOL ENERGY, V40, P335
[5]   Modelling of three-dimensional jet array impingement and heat transfer on a concave surface [J].
Craft, T. J. ;
Iacovides, H. ;
Mostafa, N. A. .
INTERNATIONAL JOURNAL OF HEAT AND FLUID FLOW, 2008, 29 (03) :687-702
[6]  
GRENARD P, 2007, 2 EUR C AER SCI MAY
[7]  
GUPTA CL, 1961, SOL ENERGY, V11, P25
[8]   Thermohydraulic performance of solar air heaters with roughened absorber plates [J].
Gupta, D ;
Solanki, SC ;
Saini, JS .
SOLAR ENERGY, 1997, 61 (01) :33-42
[9]   Conjugate heat transfer predictions in two-dimensional ribbed passages [J].
Iaccarino, G ;
Ooi, A ;
Durbin, PA ;
Behnia, M .
INTERNATIONAL JOURNAL OF HEAT AND FLUID FLOW, 2002, 23 (03) :340-345
[10]   Flow and heat transfer in straight cooling passages with inclined ribs on opposite walls: an experimental and computational study [J].
Iacovides, H ;
Kelemenis, G ;
Raisee, A .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2003, 27 (03) :283-294