Iridium oxide based coaxial pH ultramicroelectrode

被引:26
|
作者
Huang, Xiao-rong [1 ]
Ren, Qiong-qiong [1 ]
Yuan, Xiao-jun [1 ]
Wen, Wei [1 ]
Chen, Wei [1 ]
Zhan, Dong-ping [2 ]
机构
[1] Huazhong Univ Sci & Technol, Wuhan Natl Lab Optoelect, Britton Chance Ctr Biomed Photon, Coll Life Sci & Technol, Wuhan 430074, Hubei, Peoples R China
[2] Xiamen Univ, State Key Lab Phys Chem Solid Surfaces, Xiamen 361005, Peoples R China
基金
高等学校博士学科点专项科研基金; 中国国家自然科学基金;
关键词
Coaxial pH ultramicroelectrode; Iridium oxide; Electrodeposition; OXIDATIVE BURST; OILSEED RAPE; ELECTRODE; FILM; FABRICATION; ARRAY;
D O I
10.1016/j.elecom.2013.12.012
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
In this communication, a coaxial pH microelectrode consisting of a working electrode made of IrOx and a Ag/AgCl reference electrode has been developed. The outer wall of the glass capillary with a tip diameter of 5 pm was sputtered with Au and then IrOx film was electrodeposited on the Au layer, while the inside of the capillary was a Ag/AgCl wire which can serve as a reference electrode. This electrode presented a linear response in the pH range from 2.0 to 12.0 with a sensitivity of 58.73 +/- 0.41 mV/pH. In selectivity tests, several alkaline cations such as Na+ and K+ didn't interfere with the performance of the electrode. Furthermore, the ultramicroelectrode exhibited rapid response times ranging from 0.5 s to 5 s depending on the solution pH. The excellent performance and ultramicro-size of this pH sensor make it very promising for in situ/in vivo pH measurements. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:35 / 37
页数:3
相关论文
共 50 条
  • [41] Prevention of biofouling on iridium oxide based pH sensors using polyvinyl alcohol hydrogels
    Sharma, Hrishita
    Kalita, Deepjyoti
    Panda, Ritik
    Mirza, Khalid B.
    2023 IEEE SENSORS, 2023,
  • [42] An electrochemically cleanable pH electrode based on an electrodeposited iridium oxide-ruthenium oxide-titanium composite
    Hu, Guangxing
    Diao, Yongxing
    Cui, Shuang
    Wang, Hongda
    Shi, Yan
    Li, Zhuang
    ANALYST, 2024, 149 (04) : 1327 - 1336
  • [43] AN IRIDIUM-IRIDIUM OXIDE ELECTRODE FOR INVIVO MONITORING OF BLOOD-PH CHANGES
    PAPESCHI, G
    BORDI, S
    CARLA, M
    CRISCIONE, L
    LEDDA, F
    JOURNAL OF MEDICAL ENGINEERING & TECHNOLOGY, 1981, 5 (02) : 86 - 88
  • [44] A fabrication of iridium oxide film pH micro-sensor on Pt-ultramicroelectrode and its application on in-situ pH distribution of 316L stainless steel corrosion at open circuit potential
    Zhu, Zejie
    Liu, Xiaoyan
    Ye, Zhenni
    Zhang, Jianqing
    Cao, Fahe
    Zhang, Junxi
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 255 : 1974 - 1982
  • [45] Printable and Flexible Iridium Oxide-Based pH Sensor by a Roll-to-Roll Process
    Chawang, Khengdauliu
    Bing, Sen
    Chiao, Jung-Chih
    CHEMOSENSORS, 2023, 11 (05)
  • [46] A wireless, ingestible pH sensing capsule system based on iridium oxide for monitoring gastrointestinal health
    Cheng, Chen
    Wu, Yue
    Li, Xinru
    An, Zijian
    Lu, Yanli
    Zhang, Fenni
    Su, Bin
    Liu, Qingjun
    SENSORS AND ACTUATORS B-CHEMICAL, 2021, 349
  • [47] Fabrication of metal-based pH sensing electrode via electrodeposition of iridium oxide nanoparticles
    Khalil, Munawar
    Yu, Jianjia
    Liu, Ning
    Lee, Robert L.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2014, 248
  • [48] Solid state iridium oxide-titanium based sensor for flow injection pH measurements
    Hassan, SSM
    Marzouk, SAM
    Badawy, NM
    ANALYTICAL LETTERS, 2002, 35 (08) : 1301 - 1311
  • [49] PH-SENSITIVE SPUTTERED IRIDIUM OXIDE-FILMS
    KATSUBE, T
    LAUKS, I
    ZEMEL, JN
    SENSORS AND ACTUATORS, 1982, 2 (04): : 399 - 410
  • [50] A long-term stable iridium oxide pH electrode
    Wang, M
    Yao, S
    Madou, M
    SENSORS AND ACTUATORS B-CHEMICAL, 2002, 81 (2-3) : 313 - 315