Iridium oxide based coaxial pH ultramicroelectrode

被引:26
|
作者
Huang, Xiao-rong [1 ]
Ren, Qiong-qiong [1 ]
Yuan, Xiao-jun [1 ]
Wen, Wei [1 ]
Chen, Wei [1 ]
Zhan, Dong-ping [2 ]
机构
[1] Huazhong Univ Sci & Technol, Wuhan Natl Lab Optoelect, Britton Chance Ctr Biomed Photon, Coll Life Sci & Technol, Wuhan 430074, Hubei, Peoples R China
[2] Xiamen Univ, State Key Lab Phys Chem Solid Surfaces, Xiamen 361005, Peoples R China
基金
高等学校博士学科点专项科研基金; 中国国家自然科学基金;
关键词
Coaxial pH ultramicroelectrode; Iridium oxide; Electrodeposition; OXIDATIVE BURST; OILSEED RAPE; ELECTRODE; FILM; FABRICATION; ARRAY;
D O I
10.1016/j.elecom.2013.12.012
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
In this communication, a coaxial pH microelectrode consisting of a working electrode made of IrOx and a Ag/AgCl reference electrode has been developed. The outer wall of the glass capillary with a tip diameter of 5 pm was sputtered with Au and then IrOx film was electrodeposited on the Au layer, while the inside of the capillary was a Ag/AgCl wire which can serve as a reference electrode. This electrode presented a linear response in the pH range from 2.0 to 12.0 with a sensitivity of 58.73 +/- 0.41 mV/pH. In selectivity tests, several alkaline cations such as Na+ and K+ didn't interfere with the performance of the electrode. Furthermore, the ultramicroelectrode exhibited rapid response times ranging from 0.5 s to 5 s depending on the solution pH. The excellent performance and ultramicro-size of this pH sensor make it very promising for in situ/in vivo pH measurements. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:35 / 37
页数:3
相关论文
共 50 条
  • [21] THE IRIDIUM IRIDIUM OXIDE ELECTRODE FOR INVIVO MEASUREMENT OF ESOPHAGEAL AND GASTRIC PH
    PAPESCHI, G
    MERIGLIANO, S
    ZANINOTTO, G
    BAESSATO, M
    ANCONA, E
    LARINI, M
    JOURNAL OF MEDICAL ENGINEERING & TECHNOLOGY, 1984, 8 (05) : 221 - 223
  • [22] Improved iridium/iridium oxide pH electrode through supercritical treatment
    Dai, Mengting
    Xia, Jinfeng
    Xue, Zhenhai
    Zhou, Guohong
    Jiang, Danyu
    Heng, Yuerong
    Yu, Cuiyan
    Miao, Jiayan
    Li, Qiang
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2022, 922
  • [23] Improved iridium/iridium oxide pH electrode through supercritical treatment
    Dai, Mengting
    Xia, Jinfeng
    Xue, Zhenhai
    Zhou, Guohong
    Jiang, Danyu
    Heng, Yuerong
    Yu, Cuiyan
    Miao, Jiayan
    Li, Qiang
    Journal of Electroanalytical Chemistry, 2022, 922
  • [24] Microscopic measurement of pH with iridium oxide microelectrodes
    Wipf, DO
    Ge, FY
    Spaine, TW
    Bauer, JE
    ANALYTICAL CHEMISTRY, 2000, 72 (20) : 4921 - 4927
  • [25] Surface modification of iridium oxide ph electrode
    South China University of Technology, Guangzhou 510640, China
    不详
    不详
    Xiyou Jinshu Cailiao Yu Gongcheng, 2007, 4 (636-639):
  • [26] Adsorptive stripping analysis of trace nickel at iridium-based ultramicroelectrode arrays
    Wang, J
    Wang, JY
    Adeniyi, WK
    Kounaves, SP
    ELECTROANALYSIS, 2000, 12 (01) : 44 - 47
  • [27] Surface modification of iridium oxide pH electrode
    Chen Dongchu
    Fu Chaoyang
    Zheng Jiasheng
    Li Wenfang
    RARE METAL MATERIALS AND ENGINEERING, 2007, 36 (04) : 636 - 639
  • [28] Iridium oxide and cobalt hydroxide microfluidic-based potentiometric pH sensor
    Xiao, Weiyu
    Dong, Qiuchen
    MICROCHIMICA ACTA, 2023, 190 (11)
  • [29] Characterization of pH Sensors Based on Iridium Oxide and Gold Encapsulated Polypropylene Membranes
    Chawang, Khengdauliu
    Chou, Shih-Cheng
    Bing, Sen
    Wu, Pu-Wei
    Chiao, J-C
    2021 IEEE SENSORS, 2021,
  • [30] Fabrication and Characterization of Iridium Oxide pH Microelectrodes Based on Sputter Deposition Method
    Xi, Ye
    Guo, Zhejun
    Wang, Longchun
    Xu, Qingda
    Ruan, Tao
    Liu, Jingquan
    SENSORS, 2021, 21 (15)