A hybrid photodetector using the Timepix semiconductor assembly for photoelectron detection

被引:8
作者
Anton, Gisela [1 ]
Gebert, Ulrike [1 ]
Michel, Thilo [1 ]
Ruegheimer, Tilman K. [1 ]
机构
[1] Univ Erlangen Nurnberg, Erlangen Ctr Astroparticle Phys, D-91058 Erlangen, Germany
关键词
Photo-detection; Hybrid photon detector; HPD; Timepix; Medipix; PIXEL READOUT CHIP; PHOTON DETECTOR;
D O I
10.1016/j.nima.2008.12.053
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We present a hybrid photomultiplier concept which employs the pixelated semiconductor detector Timepix for the detection of the photoelectrons. Timepix has been developed by the MEDIPIX collaboration. It comprises 256 x 256 pixels with 55 mu m pixel pitch. By setting an energy threshold it allows to identify single electrons and, therefore, single photons with high resolution. An appropriate electric field between the photocathode and the Timepix configures an image of the photocathode on the Timepix. A high frequency clock enables the determination of the arrival time of each photon. Test measurements and further design considerations are presented. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:205 / 208
页数:4
相关论文
共 7 条
[1]   First operation of a hybrid photon detector prototype with electrostatic cross-focussing and integrated silicon pixel readout [J].
Alemi, M ;
Campbell, M ;
Gys, T ;
Mikulec, B ;
Piedigrossi, D ;
Puertolas, D ;
Rosso, E ;
Schomaker, R ;
Snoeys, W ;
Wyllie, K .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 449 (1-2) :48-59
[2]  
ANTON G, 2007, Patent No. 2007005072
[3]   The pixel hybrid photon detectors for the LHCb-rich project [J].
Gys, T .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 465 (01) :240-246
[4]   Timepix, a 65k programmable pixel readout chip for arrival time, energy and/or photon counting measurements [J].
Llopart, X. ;
Ballabriga, R. ;
Campbell, M. ;
Tlustos, L. ;
Wong, W. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 581 (1-2) :485-494
[5]   Medipix2:: a 64-k pixel readout chip with 55 μm square elements working in single photon counting mode [J].
Llopart, X ;
Campbell, M ;
Dinapoli, R ;
Segundo, DS ;
Pemigotti, E .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (05) :2279-2283
[6]   Experimental demonstration of a hybrid photon detector concept based on the Timepix detector [J].
Ruegheimer, Tilman K. ;
Gebert, Ulrike ;
Michel, Thilo ;
Anton, Gisela ;
Seguinot, Jacques ;
Joram, Christian .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2008, 595 (02) :353-358
[7]   GridPix: An integrated readout system for gaseous detectors with a pixel chip as anode [J].
van der Graaf, Harry .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (02) :1023-1026