A new method for determination of fluoride ion in commodity tea by ion-exclusion chromatography

被引:9
|
作者
Zhou, Lili [1 ]
Li, Huaiping [1 ]
Ye, Shanrong [1 ]
Tan, Heping [1 ]
机构
[1] Natl Inst Measurement & Testing Technol, Stand & Testing Technol Tea Key Lab Sichuan Pr, Chengdu, Sichuan, Peoples R China
关键词
Fluoride ion; ion-exclusion chromatography; interfering ion; tea; Ion de fluor; te; ion interferente; cromatografia ionica de exclusion; INORGANIC ANIONS; SEPARATION; BLACK; ACIDS;
D O I
10.1080/19476337.2018.1441188
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
Due to the effect of interfering ion, the content of fluoride ion in tea brew, detected by ion-exchange chromatography, was markedly higher than ion-selective electrode. Ion-exclusion chromatography, a new method for the determination of fluoride ion in tea brew, was proposed and evaluated in this study. Two Metrosep organic acid columns in series resulted in better separation of fluoride ion than single column. The most suitable organic modifier for eluent and its percentage were checked, the optimal conditions of the mobile phase was 0.33mM sulfuric acid solution containing 10.5% (v/v) acetone, at a flow rate of 0.5mL/min. Satisfactory sensitivity and wide linearity range were obtained. The applicability of the method was demonstrated by the analysis of various tea samples in China, the accuracy of the results was proved by recovery tests, and the concordance with the values was obtained by ion-selective electrode. RESUMENDebido al ion interferente, se detecto el contenido de iones de fluor en una infusion de te empleando cromatografia ionica de exclusion. Este metodo permitio que se registrara un nivel mas elevado que utilizando el electrodo selectivo de iones. El presente estudio propuso y evaluo el metodo de cromatografia ionica de exclusion, un procedimiento nuevo empleado para determinar la presencia de iones de fluor en el te preparado. Cabe senalar que dos columnas Metrosep en serie de acido organico produjeron una mejor separacion de iones de fluor que una sola columna. Se determino el modificador organico mas adecuado y su porcentaje para el eluyente: las condiciones optimas de la fase movil estan dadas por 0.33 mM solucion de acido sulfurico con 10.5% (v/v) de acetona y un caudal de 0.5 mL/min. Ello permitio obtener una sensibilidad satisfactoria y un amplio rango de linealidad. La aplicabilidad del metodo fue demostrada a partir del analisis de varias muestras de te en China. La precision de los resultados se demostro utilizando pruebas de recuperacion, mientras que la concordancia con los valores se comprobo empleando un electrodo selectivo de iones.
引用
收藏
页码:637 / 641
页数:5
相关论文
共 50 条
  • [1] Ion-exclusion Chromatography
    Bohacova, I.
    Nagyova, A.
    Halko, R.
    CHEMICKE LISTY, 2016, 110 (09): : 616 - 624
  • [2] DETERMINATION OF BORON USING ION-EXCLUSION CHROMATOGRAPHY WITH POSTCOLUMN DERIVATIZATION METHOD
    INOUE, Y
    DATE, Y
    BUNSEKI KAGAKU, 1994, 43 (05) : 365 - 370
  • [3] RETENTION MECHANISM OF ION-EXCLUSION CHROMATOGRAPHY
    GLOD, BK
    CHEMIA ANALITYCZNA, 1994, 39 (04): : 399 - 422
  • [4] Modelling of Ion-Exclusion Chromatography and Vacancy Ion-Exclusion Chromatography of Selected Aromatic Acids on Strongly Acidic Resin in the H+ Form
    Zapala, W.
    Kaczmarski, K.
    ACTA CHROMATOGRAPHICA, 2010, 22 (01) : 1 - 25
  • [5] Optimization Conditions For Determination of Cosmetic Preservatives using Ion-Exclusion Chromatography
    Kalal, Sid H.
    Rafiei, J.
    Bani, F.
    Khanchi, A. R.
    Hoveidi, H.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH, 2010, 4 (02) : 289 - 296
  • [6] Determination of organic acids in air by capillary electrophoresis and ion-exclusion chromatography
    Levart, A
    Gucek, M
    Pihlar, B
    Veber, M
    CHROMATOGRAPHIA, 2000, 51 (1) : S321 - S324
  • [7] Determination of organic acids in air by capillary electrophoresis and ion-exclusion chromatography
    A. Levart
    M. Guček
    B. Pihlar
    M. Veber
    Chromatographia, 2000, 51 : S321 - S324
  • [8] Determination of volatile fatty acids in landfill leachates by ion-exclusion chromatography
    Yamamoto, A
    Yasuhara, A
    Kodama, S
    Matsunaga, A
    Suzuki, S
    Mohri, S
    Yamada, M
    JOURNAL OF SEPARATION SCIENCE, 2004, 27 (04) : 325 - 329
  • [9] Determination of aromatic carboxylic acids by ion-exclusion chromatography with direct conductivity detection
    Hong, Yu
    Yan, Wang
    Yuan Xiao-Yu
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2008, 36 (03) : 393 - 396
  • [10] Mechanism of formation of system peaks in ion-exclusion chromatography
    Novic, Milko
    Haddad, Paul R.
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1305 : 188 - 192