Dual-mobility implants prevent hip dislocation following hip revision in obese patients

被引:26
|
作者
Hernigou, Philippe [1 ]
Auregan, Jean Charles [2 ]
Potage, Damien [1 ]
Roubineau, Francois [1 ]
Lachaniette, Charles Henri Flouzat [1 ]
Dubory, Arnaud [1 ]
机构
[1] Univ Paris E UPEC, Dept Orthopaed Surg, Hop Henri Mondor, F-94010 Creteil, France
[2] Univ Paris West, Hop Antoine Beclere, Dept Orthoped Surg, F-92140 Clamart, France
关键词
Dual mobility; Obesity; Hip revision; Dislocation; BODY-MASS INDEX; ARTHROPLASTY; CUP; WEIGHT; THA; STABILITY; OUTCOMES; HEALTH; WOMEN; RISK;
D O I
10.1007/s00264-016-3316-y
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose Revision total hip arthroplasty (THA) is associated with increased rates of dislocation in obese patients. It is not known whether dual-mobility implants decrease dislocation in these patients with obesity. Methods We retrospectively reviewed two groups of revision THAs to compare the dislocation rate between 32 obese patients (BMI >30 kg/m(2)) with standard cups, and 35 ob(e)se patients (BMI >30 kg/m(2)) with dual-mobility cups. All patients received the same implants except for diameter head (32-mm head with standard cups and 28-mm head with dual mobility) and had the same cemented stem that was not changed at revision. The patients were followed at routine intervals and were specifically queried about dislocation. The two groups were similar in terms of age, gender, causes of revision and follow-up since the primary arthroplasty. Results With standard liners, more hips in obese patients dislocated than did hips in obese patients who received dual-mobility implants. The number of dislocations in standard hips was at one year follow-up 15.6 % (5 of 32) compared with 0 % in dual-mobility hips and was at five year follow-up 21.8 % (7 of 32) compared with 2.8 % (1 of 35). After a mean follow-up of seven years no cases of loosening were found. Five patients in the obese group with a standard liner underwent re-revision surgery, the additional re-operations being necessary to treat recurrent postoperative dislocation. Conclusions Obese patients should be counselled about the important risk of dislocation that occurs with standard liners after revision THA. Dual-mobility liners in these patients with hip revision is an efficient technique to prevent post-operative hip dislocation.
引用
收藏
页码:469 / 473
页数:5
相关论文
共 50 条
  • [1] Dual-mobility implants prevent hip dislocation following hip revision in obese patients
    Philippe Hernigou
    Jean Charles Auregan
    Damien Potage
    François Roubineau
    Charles Henri Flouzat Lachaniette
    Arnaud Dubory
    International Orthopaedics, 2017, 41 : 469 - 473
  • [2] Early Intraprosthetic Dislocation in a Revision Dual-mobility Hip Prosthesis
    Banka, Trevor R.
    Ast, Michael P.
    Parks, Michael L.
    ORTHOPEDICS, 2014, 37 (04) : E395 - E397
  • [3] Dual-Mobility Implants and Constrained Liners in Revision Total Hip Arthroplasty
    Chisari, Emanuele
    Ashley, Blair
    Sutton, Ryan
    Largoza, Garrett
    Di Spagna, Marco
    Goyal, Nitin
    Courtney, P. Maxwell
    Parvizi, Javad
    ARTHROPLASTY TODAY, 2022, 13 : 8 - 12
  • [4] Dual-mobility bearings in complex revision hip arthroplasty
    Wakeling, Christopher P.
    Sandiford, Nemandra A.
    Ghani, Rafia
    Bridle, Simon J.
    Mitchell, Philip A.
    Hutt, Jonathan R. B.
    HIP INTERNATIONAL, 2022, 32 (04) : 460 - 465
  • [5] A cost-effectiveness assessment of dual-mobility bearings in revision hip arthroplasty
    Khoshbin, A.
    Haddad, F. S.
    Ward, S.
    O'hEireamhoin, S.
    Wu, J.
    Nherera, L.
    Atrey, A.
    BONE & JOINT JOURNAL, 2020, 102B (09) : 1128 - 1135
  • [6] Dual-Mobility Constructs in Revision Total Hip Arthroplasties
    Abdel, Matthew P.
    JOURNAL OF ARTHROPLASTY, 2018, 33 (05) : 1328 - 1330
  • [7] Causes for revision of dual-mobility and standard primary total hip arthroplasty
    Prudhon, Jean-Louis
    Desmarchelier, Romain
    Hamadouche, Moussa
    Delaunay, Christian
    Verdier, Regis
    INTERNATIONAL ORTHOPAEDICS, 2017, 41 (03) : 455 - 459
  • [8] Is Cemented Dual-Mobility Cup a Reliable Option in Primary and Revision Total Hip Arthroplasty: A Systematic Review
    Ciolli, Gianluca
    Mesnard, Guillaume
    Deroche, Etienne
    Gunst, Stanislas
    Batailler, Cecile
    Servien, Elvire
    Lustig, Sebastien
    JOURNAL OF PERSONALIZED MEDICINE, 2023, 13 (01):
  • [9] Cementless dual-mobility cup in total hip arthroplasty revision
    Prudhon, Jean Louis
    Steffann, Francois
    Ferreira, Andre
    Verdier, Regis
    Aslanian, Thierry
    Caton, Jacques
    INTERNATIONAL ORTHOPAEDICS, 2014, 38 (12) : 2463 - 2468
  • [10] Dual-Mobility Cups in Primary Total Hip Arthroplasty
    Bellova, Petri
    Goronzy, Jens
    Riedel, Roman
    Grothe, Tim
    Hartmann, Albrecht
    Guenther, Klaus-Peter
    ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE, 2023, 161 (01): : 74 - 84