A novel method for post-mortem interval estimation based on tissue nano-mechanics

被引:18
作者
De-Giorgio, Fabio [1 ]
Nardini, Matteo [2 ]
Foti, Federica [1 ]
Minelli, Eleonora [2 ]
Papi, Massimiliano [2 ]
D'Aloja, Ernesto [3 ]
Pascali, Vincenzo L. [1 ]
De Spirito, Marco [2 ]
Ciasca, Gabriele [2 ]
机构
[1] Univ Cattolica Sacro Cuore, Fdn Policlin Univ A Gemelli IRCCS, Inst Publ Hlth, Rome, Italy
[2] Univ Cattolica Sacro Cuore, Fdn Policlin Univ A Gemelli IRCCS, Inst Phys, Rome, Italy
[3] Univ Cagliari, Dept Med Sci & Publ Hlth, Cagliari, CA, Italy
关键词
Time since death; Rigor mortis; Atomic force microscope; Nano-mechanics; RIGOR-MORTIS; MUSCLE; TIME; ONSET; DEATH; RED; SIGNATURE;
D O I
10.1007/s00414-019-02034-z
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
Forensic estimation of post-mortem interval relies on different methods, most of which, however, have practical limitations or provide insufficient results, still lacking a gold standard method. In order to better understand the phenomenon of rigor mortis and its applicability to the post-mortem interval estimation, we decided to use atomic force microscopy, a tool often employed to measure mechanical properties of adherent cells. Thus, we surgically removed skeletal muscle samples of three forensic cases from 0 to 120h post-mortem and quantitatively evaluate two parameters: the Young's modulus (E), which gives information about the sample stiffness, and the hysteresis (H), which estimates the contribution of viscous forces. Despite being a preliminary study, the obtained results show that the temporal behavior of E well correlates with the expected evolution of rigor mortis between 0 and 48h post-mortem, and then monotonically decreases over time. Unfortunately, it is strongly affected by inter-individual variability. However, we found that H provides measurable data along a time-dependent curve back to the starting point, and these data measured on different subjects collapse onto a single master curve, getting rid of the inter-individual variability. Although a larger sampling should be performed to improve the result reliability, this finding is strongly suggestive that the evaluation of rigor mortis should involve the measure of the nanoscale dissipative behavior of muscular tissues.
引用
收藏
页码:1133 / 1139
页数:7
相关论文
共 26 条
[1]   Estimation of the time since death-reconsidering the re-establishment of rigor mortis [J].
Anders, Sven ;
Kunz, Michaela ;
Gehl, Axel ;
Sehner, Susanne ;
Raupach, Tobias ;
Beck-Bornholdt, Hans-Peter .
INTERNATIONAL JOURNAL OF LEGAL MEDICINE, 2013, 127 (01) :127-130
[2]   Mapping viscoelastic properties of healthy and pathological red blood cells at the nanoscale level [J].
Ciasca, G. ;
Papi, M. ;
Di Claudio, S. ;
Chiarpotto, M. ;
Palmieri, V. ;
Maulucci, G. ;
Nocca, G. ;
Rossi, C. ;
De Spirito, M. .
NANOSCALE, 2015, 7 (40) :17030-17037
[3]   Nano-mechanical signature of brain tumours [J].
Ciasca, Gabriele ;
Sassun, Tanya Enny ;
Minelli, Eleonora ;
Antonelli, Manila ;
Papi, Massimiliano ;
Santoro, Antonio ;
Giangaspero, Felice ;
Delfini, Roberto ;
De Spirito, Marco .
NANOSCALE, 2016, 8 (47) :19629-19643
[4]   Changes in cellular mechanical properties during onset or progression of colorectal cancer [J].
Ciasca, Gabriele ;
Papi, Massimiliano ;
Minelli, Eleonora ;
Palmieri, Valentina ;
De Spirito, Marco .
WORLD JOURNAL OF GASTROENTEROLOGY, 2016, 22 (32) :7203-7214
[5]   Re-establishment of rigor mortis: evidence for a considerably longer post-mortem time span [J].
Crostack, Chiara ;
Sehner, Susanne ;
Raupach, Tobias ;
Anders, Sven .
INTERNATIONAL JOURNAL OF LEGAL MEDICINE, 2017, 131 (04) :1039-1042
[6]   Nanomechanical mapping of latent fingermarks: A preliminary investigation into the changes in surface interactions and topography over time [J].
Dorakumbura, Buddhika N. ;
Becker, Thomas ;
Lewis, Simon W. .
FORENSIC SCIENCE INTERNATIONAL, 2016, 267 :16-24
[7]   A beginner's guide to atomic force microscopy probing for cell mechanics [J].
Gavara, Nuria .
MICROSCOPY RESEARCH AND TECHNIQUE, 2017, 80 (01) :75-84
[8]   Investigating cell mechanics with atomic force microscopy [J].
Haase, Kristina ;
Pelling, Andrew E. .
JOURNAL OF THE ROYAL SOCIETY INTERFACE, 2015, 12 (104)
[9]   Does the sequence of onset of rigor mortis depend on the proportion of muscle fibre types and on intra-muscular glycogen content? [J].
Kobayashi, M ;
Takatori, T ;
Nakajima, M ;
Saka, K ;
Iwase, H ;
Nagao, M ;
Niijima, H ;
Matsuda, Y .
INTERNATIONAL JOURNAL OF LEGAL MEDICINE, 1999, 112 (03) :167-171
[10]   Onset of rigor mortis is earlier in red muscle than in white muscle [J].
Kobayashi, M ;
Takatori, T ;
Nakajima, M ;
Sakurada, K ;
Hatanaka, K ;
Ikegaya, H ;
Matsuda, Y ;
Iwase, H .
INTERNATIONAL JOURNAL OF LEGAL MEDICINE, 2000, 113 (04) :240-243