An Analytical method for detecting instability in grid-connected doubly-fed induction generator

被引:2
作者
Nasab, Mohammad Rajabi [1 ]
Yaghobi, Hamid [1 ]
机构
[1] Semnan Univ, Fac Elect & Comp Engn, Semnan, Iran
关键词
OF-STEP DETECTION; SYNCHRONOUS GENERATOR; TRANSIENT STABILITY; WIND TURBINES; ANGULAR-VELOCITY; FAULT RESPONSES; POWER-CONTROL; DFIG; SYSTEMS;
D O I
10.1049/rpg2.12068
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Doubly-fed induction generator (DFIG) is among the most attractive technologies in wind farms. As the penetration of wind power into the grid has increased in recent years, protecting of wind farm's generators against grid disturbances has become a major issue for the power system industry. Transient instability (TI) is among the most frequent phenomena due to severe grid disturbances. This phenomenon might cause significant damages to network equipment. In DFIG based wind turbine (WT), when the crowbar circuit is activated, the rotor winding is short-circuited and the power converter is blocked. At this moment, the DFIG operational mode is temporarily changed to squirrel-cage induction generator (SCIG). This lead to reactive power absorption and voltage drop, that might cause electromechanical oscillations and unstable condition. This study presents an analytical method for detection TI of a grid-connected DFIG based on analysis of angular velocity and acceleration data, which are readily obtained from locally measured quantities. This technique works on a setting-free manner, i.e. revising would not be required even when the network configuration changes, which is a favourable feature in protective relaying. The performance of the proposed method is verified using MATLAB/Simulink. Simulation results prove the method's reliability and simplicity.
引用
收藏
页码:778 / 793
页数:16
相关论文
共 30 条
[1]   Out-of-Step Protection Based on Equal Area Criterion [J].
Alinezhad, Bahman ;
Karegar, Hossein Kazemi .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2017, 32 (02) :968-977
[2]   Detailed Investigation and Performance Improvement of the Dynamic Behavior of Grid-Connected DFIG-Based Wind Turbines Under LVRT Conditions [J].
Alsmadi, Yazan M. ;
Xu, Longya ;
Blaabjerg, Frede ;
Ortega, Alejandro J. Pina ;
Abdelaziz, Almoataz Y. ;
Wang, Aimeng ;
Albataineh, Zaid .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2018, 54 (05) :4795-4812
[3]   STABILITY SIMULATION OF WIND TURBINE SYSTEMS [J].
ANDERSON, PM ;
BOSE, A .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1983, 102 (12) :3791-3795
[4]   A review of power converter topologies for wind generators [J].
Baroudi, Janial A. ;
Dinavahi, Venkata ;
Knight, Andrew M. .
RENEWABLE ENERGY, 2007, 32 (14) :2369-2385
[5]  
Cao W, 2012, ADV WIND POWER, V1, P177
[6]   Comparative study on fault responses of synchronous generators and wind turbine generators using transient stability index based on transient energy function [J].
Chowdhury, M. A. ;
Hosseinzadeh, N. ;
Shen, W. X. ;
Pota, H. R. .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2013, 51 :145-152
[7]   Quantitative assessment and comparison of fault responses for synchronous generator and wind turbine generators based on modified transient energy function [J].
Chowdhury, Md Ayaz ;
Shen, Weixiang ;
Hosseinzadeh, Nasser ;
Pota, Hemanshu Roy .
IET RENEWABLE POWER GENERATION, 2014, 8 (05) :474-483
[8]  
Duong M.Q., 2016, IEEE INT C SUST EN T
[9]   An analytical method for analysis of large-disturbance stability of induction generators [J].
Grilo, Ahda Pionkoski ;
Mota, Alexandre de Assis ;
Mota, Lia Toledo Moreira ;
Freitas, Walmir .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2007, 22 (04) :1861-1869
[10]   Review on FRT solutions for improving transient stability in DFIG-WTs [J].
Jerin, Amalorpavaraj Rini Ann ;
Kaliannan, Palanisamy ;
Subramaniam, Umashankar ;
El Moursi, Mohammed Shawky .
IET RENEWABLE POWER GENERATION, 2018, 12 (15) :1786-1799