In Vitro Strehl Ratios with Spherical, Aberration-Free, Average, and Customized Spherical Aberration-Correcting Intraocular Lenses

被引:90
作者
Pieh, Stefan [1 ]
Fiala, Werner [1 ]
Malz, Andre [2 ]
Stork, Wilhelm [2 ]
机构
[1] Med Univ Vienna, Dept Ophthalmol & Optometry, A-1090 Vienna, Austria
[2] Univ Karlsruhe, Inst Informat Proc Technol, Karlsruhe, Germany
关键词
HIGHER-ORDER ABERRATIONS; OPTICAL ABERRATIONS; CONTRAST SENSITIVITY; CORNEAL TOPOGRAPHY; HUMAN EYE; DECENTRATION; DESIGN; TILT; ASPHERICITY; PERFORMANCE;
D O I
10.1167/iovs.08-2187
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To determine in vitro image qualities of artificial eyes achieved with spherical, aberration-free, average spherical aberration-correcting, and customized spherical aberration-correcting IOLs in centered, decentered, and tilted positions. METHODS. The in vitro performance of these IOL models was determined by optical bench measurements. The experimental setup included a laser light source controlled by aperture stops that corresponded to 3- and 5-mm pupil apertures, an artificial eye with three alternative corneal models exhibiting low, intermediate, and high spherical aberration ( SA), IOLs mounted to an immersed IOL holder that could be moved laterally and tilted, and a charge-coupled device camera and software to determine three-dimensional point spread function (PSF), modulation transfer function, and Strehl ratio. RESULTS. Differences among the various lens models turned out to be low for a 3- mm pupil. For a pupil aperture of 5 mm, customized IOLs showed the best results for perfect lens positioning. With ongoing decentration and tilt, customized IOLs rapidly lost their advantages, particularly in corneas with high SA and IOLs of high diopters. Spherical IOLs were always inferior to aberration-free IOLs. CONCLUSIONS. Reasonably well-centered aberration-correcting IOLs may provide considerably better image quality than conventional spherical IOLs. In the presence of significant postoperative decentration and tilt of the IOL, aberration-free IOLs are the safest option among the various intraocular lens designs. ( Invest Ophthalmol Vis Sci. 2009; 50: 1264-1270) DOI:10.1167/iovs.08-2187
引用
收藏
页码:1264 / 1270
页数:7
相关论文
共 31 条
[1]   Optical performance of 3 intraocular lens designs in the presence of decentration [J].
Altmann, GE ;
Nichamin, LD ;
Lane, SS ;
Pepose, JS .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (03) :574-585
[2]   The human eye is an example of robust optical design [J].
Artal, P ;
Benito, A ;
Tabernero, J .
JOURNAL OF VISION, 2006, 6 (01) :1-7
[3]   Neural compensation for the eye's optical aberrations [J].
Artal, P ;
Chen, L ;
Fernández, EJ ;
Singer, B ;
Manzanera, S ;
Williams, DR .
JOURNAL OF VISION, 2004, 4 (04) :281-287
[4]   DESIGN OF ASPHERIC INTRAOCULAR LENSES [J].
ATCHISON, DA .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 1991, 11 (02) :137-146
[5]   Contrast sensitivity and higher order aberrations in eyes implanted with AcrySof IQ SN60WF and AcrySof SN60AT interocular lenses [J].
Awwad, Shady T. ;
Warmerdam, Dorotheea ;
Bowman, R. Wayne ;
Dwarakanathan, Surendar ;
Cavanagh, H. Dwight ;
McCulley, James P. .
JOURNAL OF REFRACTIVE SURGERY, 2008, 24 (06) :619-625
[6]   Tilt and decentration of three-piece foldable high-refractive silicone and hydrophobic acrylic Intraocular lenses with 6-mm optics in an intraindividual comparison [J].
Baumeister, M ;
Neidhardt, B ;
Strobel, J ;
Kohnen, T .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2005, 140 (06) :1051-1058
[7]   Evaluation of relationships among refractive and topographic parameters [J].
Budak, K ;
Khater, TT ;
Friedman, NJ ;
Holladay, JT ;
Koch, DD .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1999, 25 (06) :814-820
[8]  
Carney LG, 1997, INVEST OPHTH VIS SCI, V38, P311
[9]  
Dietze HH, 2005, J REFRACT SURG, V21, pS541
[10]  
GUILLON M, 1986, OPHTHAL PHYSL OPT, V6, P47, DOI 10.1111/j.1475-1313.1986.tb00699.x