An in vitro study of the compliance of paediatric tracheal tube cuffs and tracheal wall pressure

被引:11
作者
Bernet, V. [1 ]
Dullenkopf, A.
Cannizzaro, V.
Stutz, K.
Weiss, M.
机构
[1] Univ Childrens Hosp Zurich, Dept Neonatol & Intens Care Med, Zurich, Switzerland
[2] Univ Childrens Hosp Zurich, Dept Anaesthesia, Zurich, Switzerland
关键词
D O I
10.1111/j.1365-2044.2006.04785.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Cuff volume-pressure curves and cuff pressure-tracheal wall pressure relationships were investigated in eight brands of currently available cuffed, paediatric tracheal tubes with internal diameters of 5.0 mm. Cuff volume-pressure curves were measured with the cuff unrestricted and with the cuff placed within a tracheal model with wall pressure measurements. With the tracheal tube cuffs, unrestricted cuff compliance at 20 cmH(2)O cuff pressure varied between 0.06 and 0.3 ml.cmH(2)O(-1). With the cuff restricted within the model trachea, all tracheal tube cuffs became considerably less compliant (0.01-0.09 ml.cmH(2)O(-1)). We found tracheal wall pressure was similar to the cuff pressure as long as the resulting cuff diameter was sufficiently large freely to drape the inner tracheal wall. We found that, regardless of whether a higher or lower compliant tube cuff was used, cuff hyperinflation uniformly resulted in potentially compromised tracheal mucosal blood flow; cuff pressure monitoring using cuff pressure limitation is therefore strongly recommended.
引用
收藏
页码:978 / 983
页数:6
相关论文
共 24 条
[1]   Outer diameter and shape of paediatric tracheal tube cuffs at higher inflation pressures [J].
Bernet, V ;
Dullenkopf, A ;
Maino, P ;
Weiss, M .
ANAESTHESIA, 2005, 60 (11) :1123-1128
[2]   Cuff compliance of pediatric and adult cuffed tracheal tubes:: an experimental study [J].
Devys, JM ;
Schauvliège, F ;
Taylor, G ;
Plaud, B .
PEDIATRIC ANESTHESIA, 2004, 14 (08) :676-680
[3]  
DOBRIN PB, 1974, ANESTH ANALG, V53, P456
[4]   Performance of a novel pressure release valve for cuff pressure control in pediatric tracheal tubes [J].
Dullenkopf, A ;
Bernet-Buettiker, V ;
Maino, P ;
Weiss, M .
PEDIATRIC ANESTHESIA, 2006, 16 (01) :19-24
[5]   Fit and seal characteristics of a new paediatric tracheal tube with high volume-low pressure polyurethane cuff [J].
Dullenkopf, A ;
Gerber, AC ;
Weiss, M .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2005, 49 (02) :232-237
[6]   Tracheal sealing characteristics of pediatric cuffed tracheal tubes [J].
Dullenkopf, A ;
Schmitz, A ;
Gerber, AC ;
Weiss, M .
PEDIATRIC ANESTHESIA, 2004, 14 (10) :825-830
[7]   Air leakage around endotracheal tube cuffs [J].
Dullenkopf, A ;
Schmitz, A ;
Frei, M ;
Gerber, AC ;
Weiss, M .
EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2004, 21 (06) :448-453
[8]   Fluid leakage past tracheal tube cuffs: evaluation of the new Microcuff endotracheal tube [J].
Dullenkopf, A ;
Gerber, A ;
Weiss, M .
INTENSIVE CARE MEDICINE, 2003, 29 (10) :1849-1853
[9]  
Erb T, 2001, ANAESTHESIST, V50, P395, DOI 10.1007/s001010100158
[10]   ENDOTRACHEAL-TUBE CUFF PRESSURE ASSESSMENT - PITFALLS OF FINGER ESTIMATION AND NEED FOR OBJECTIVE MEASUREMENT [J].
FERNANDEZ, R ;
BLANCH, L ;
MANCEBO, J ;
BONSOMS, N ;
ARTIGAS, A .
CRITICAL CARE MEDICINE, 1990, 18 (12) :1423-1426