Simultaneous determination of notoginsenoside R1, ginsenoside Rg1, Re, Rb1 and icariin in rat plasma by ultra-performance liquid chromatography-tandem mass spectrometry

被引:37
作者
Deng, Gui-feng [1 ]
Wang, Ding-li [1 ]
Meng, Ming-xin [1 ]
Hu, Fan [1 ]
Yao, Tong-wei [1 ]
机构
[1] Zhejiang Univ, Coll Pharmaceut Sci, Dept Pharmaceut Anal & Drug Metab, Hangzhou 310058, Zhejiang, Peoples R China
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2009年 / 877卷 / 22期
关键词
Notoginsenoside R1; Ginsenoside Rg(1); Re; Rb-1; Icariin; Ultra-performance liquid chromatography-tandem mass; spectrometry; SOLID-PHASE EXTRACTION; PANAX-NOTOGINSENG; SAPONINS; RD;
D O I
10.1016/j.jchromb.2009.06.003
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An ultra-high pressure liquid chromatography-tandem mass spectrometry method has been developed and validated for identification and quantification of five major bioactive components in rat plasma after oral administration of Qihuotongqiao tablets. The analysis was performed on an Acquity, UPLC HSS T3 column (100 mm x 2.1 mm, 1.8 mu m; Waters, USA) utilizing a gradient elution profile and a mobile phase consisting of(A) water containing 0.5 mM ammonium chloride and (B) acetonitrile. Electrospray ionization (ESI) tandem interface was employed prior to mass spectrometric detection. The calibration curve was linear over the range of 4.2-416.0 ng/mL for notoginsenoside RI, 38.4-3840.0 ng/mL for ginsenoside Rg(1), 3.7-368.0 ng/mL for ginsenoside Re, 37.6-5640.0 ng/mL ginsenoside Rb-1 and 4.5-448.0ng/mL for icariin. respectively. The average accuracies ranged from 87.2 to 109.3% with RSD <= 13.7%. The results indicated that ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS) provided improved chromatographic parameters resulting in significantly increased sample throughput including lower solvent consumption and lower limits of quantitation (LLOQ) for most of target analytes compared to previous method employing conventional high-performance liquid chromatography (HPLC) separation. So. the established method was validated, sensitive and reliable for the determination of five major bioactive components in rat plasma. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:2113 / 2122
页数:10
相关论文
共 21 条
[1]  
Cai J., 2003, CHINESE J CLIN REHAB, V7, P4251
[2]   Liquid chromatography-mass spectrometry analysis of macranthoidin B, macranthoidin A, dipsacoside B, and macranthoside B in rat plasma for the pharmacokinetic investigation [J].
Chen, Chun-Yun ;
Qi, Lian-Wen ;
Yi, Ling ;
Li, Ping ;
Wen, Xiao-Dong .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (03) :159-165
[3]   Orally administered Panax notoginseng influence on rat spontaneous behaviour [J].
Cicero, AFG ;
Bandieri, E ;
Arletti, R .
JOURNAL OF ETHNOPHARMACOLOGY, 2000, 73 (03) :387-391
[4]  
Cui M, 2000, RAPID COMMUN MASS SP, V14, P1280, DOI 10.1002/1097-0231(20000730)14:14<1280::AID-RCM26>3.0.CO
[5]  
2-C
[6]  
HYE YJ, 2004, J PHARM BIOMED ANAL, V35, P207
[7]  
Jessome LL, 2006, LC GC N AM, V24, P498
[8]  
[贾敏鸽 Jia Minge], 2005, [药物分析杂志, Chinese Journal of Pharmaceutical Analysis], V25, P64
[9]   Analysis of saponins in raw and steamed Panax notoginseng using high-performance liquid chromatography with diode array detection [J].
Lau, AJ ;
Woo, SO ;
Koh, HL .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1011 (1-2) :77-87
[10]   Liquid chromatographic method for determination of four active saponins from Panax notoginseng in rat urine using solid-phase extraction [J].
Li, L ;
Zhang, JL ;
Sheng, YX ;
Ye, G ;
Guo, HZ ;
Guo, DA .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 808 (02) :177-183