QRS detection method based on fully convolutional networks for capacitive electrocardiogram

被引:33
作者
Lee, Jun Seong [1 ]
Lee, Sang Jun [1 ]
Choi, Minho [2 ]
Seo, Minseok [1 ]
Kim, Sang Woo [1 ]
机构
[1] Pohang Univ Sci & Technol, Dept Elect Engn, Pohang 790784, South Korea
[2] Pohang Univ Sci & Technol, Dept Creat IT Excellence Engn & Future IT Innovat, Pohang 790784, South Korea
关键词
Healthcare; Capacitive ECG; ECG beat detection; ECG segmentation; Deep learning; QRS complex; HEART-RATE-VARIABILITY; ECG SIGNALS; RECOGNITION; COMPONENTS; ALGORITHM; SYSTEM;
D O I
10.1016/j.eswa.2019.05.033
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
A capacitive electrocardiogram (cECG) signal is considered a promising alternative to a conventional contact electrocardiogram (ECG) signal because the cECG signal can serve the same purpose as the contact ECG signal but can be measured during daily life without causing a subject to feel uncomfortable. However, the cECG signal has a limitation in that detection of QRS complexes, which is a fundamental step to analyze heart condition, is not easy. That is because the cECG signal is sensitive to noise, especially motion noise. This paper proposes a method to detect QRS complexes in cECG signals degraded by motion noise. The proposed method is based on fully convolutional networks (FCNs) and mainly consists of three parts: the generation of ground-truth data, the FCN model, and postprocessing. A labeling process for generating the ground-truth data is proposed. Then, an FCN model that is suitable for cECG signals is proposed. The proposed FCN model uses filters of a large size to achieve a large receptive field, unlike the common FCN models used in image processing. The receptive field is sufficiently large to involve information about adjacent QRS complexes, such as the time interval between the QRS complexes and its variability. By considering the information, the proposed FCN model can reliably classify QRS complexes even in cECG signals degraded by motion noise. Additionally, postprocessing, which consists of an accumulation step and a non-maximum suppression step, is proposed to complement the proposed FCN model. In experiments with real data, the proposed method showed an average sensitivity of 96.94%, positive predictive value of 99.13%, and F1 score of 98.02%. These results demonstrate that the proposed method overcomes the limitation of a cECG signal and helps the cECG signal be widely utilized for medical or healthcare applications. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页码:66 / 78
页数:13
相关论文
共 46 条
[1]  
[Anonymous], 2015, Guyton and Hall Textbook of Medical Physiology E-Book
[2]   Self-implication and heart rate variability during simulated exposure to flight-related stimuli [J].
Bornas, X ;
Llabrés, J ;
Noguera, M ;
López, AM ;
Barceló, F ;
Tortella-Feliu, M ;
Fullana, MA .
ANXIETY STRESS AND COPING, 2004, 17 (04) :331-339
[3]   Reduction of Motion Artifacts and Improvement of R Peak Detecting Accuracy Using Adjacent Non-Intrusive ECG Sensors [J].
Choi, Minho ;
Jeong, Jae Jin ;
Kim, Seung Hun ;
Kim, Sang Woo .
SENSORS, 2016, 16 (05)
[4]   Extending the flowering period of Leucospermum hybrids through disbudding [J].
Criley, R. A. ;
Leonhardt, K. W. ;
Oka, D. ;
Shingaki, P. .
PROCEEDINGS OF THE INTERNATIONAL SYMPOSIUM ON ORNAMENTALS, NOW!, 2008, (766) :183-186
[5]   The Reliability and Accuracy of a Noncontact Electrocardiograph System for Screening Purposes [J].
Czaplik, Michael ;
Eilebrecht, Benjamin ;
Walocha, Rafael ;
Walter, Marian ;
Schauerte, Patrick ;
Leonhardt, Steffen ;
Rossaint, Rolf .
ANESTHESIA AND ANALGESIA, 2012, 114 (02) :322-327
[6]   PhysioBank, PhysioToolkit, and PhysioNet - Components of a new research resource for complex physiologic signals [J].
Goldberger, AL ;
Amaral, LAN ;
Glass, L ;
Hausdorff, JM ;
Ivanov, PC ;
Mark, RG ;
Mietus, JE ;
Moody, GB ;
Peng, CK ;
Stanley, HE .
CIRCULATION, 2000, 101 (23) :E215-E220
[7]  
Heuer S, 2009, BIOMED CIRC SYST C, P104
[8]  
Kingma DP, 2014, ARXIV
[9]   Heart rate variability: Measurement and clinical utility [J].
Kleiger, RE ;
Stein, PK ;
Bigger, JT .
ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, 2005, 10 (01) :88-101
[10]   Recognition of Slab Identification Numbers using a Fully Convolutional Network [J].
Lee, Sang Jun ;
Kwon, Wookyong ;
Koo, Gyogwon ;
Choi, Hyeyeon ;
Kim, Sang Woo .
ISIJ INTERNATIONAL, 2018, 58 (04) :696-703