A Novel and Effective Surface Design: Conducting Polymer/β-Cyclodextrin Host-Guest System for Cholesterol Biosensor

被引:47
作者
Soylemez, Saniye [1 ]
Hacioglu, Serife O. [1 ]
Kesik, Melis [1 ]
Unay, Hande [2 ]
Cirpan, Ali [1 ,2 ,4 ]
Toppare, Levent [1 ,2 ,3 ,4 ]
机构
[1] Middle E Tech Univ, Dept Chem, TR-06800 Ankara, Turkey
[2] Middle E Tech Univ, Dept Polymer Sci & Technol, TR-06800 Ankara, Turkey
[3] Middle E Tech Univ, Dept Biotechnol, TR-06800 Ankara, Turkey
[4] Middle E Tech Univ, Ctr Solar Energy Res & Applicat GUNAM, TR-06800 Ankara, Turkey
关键词
conducting polymer; beta-cyclodextrin; cholesterol biosensor; cholesterol oxidase; CARBON NANOTUBES; DIRECT ELECTROCHEMISTRY; BETA-CYCLODEXTRIN; GLUCOSE-OXIDASE; IMMOBILIZATION; REDOX; ENZYME; ACID);
D O I
10.1021/am5054493
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
The combination of supramolecules and conducting polymers (CPs) has gained much attention for the development of new immobilization matrices for biomolecules. Herein, an amperometric biosensor based on a novel conducting polymer, poly(2-(2-octyldodecyl)-4,7-di(selenoph-2-yl)-2H-benzo[d][1,2,3]triazole)) (PSBTz) and beta-cyclodextrin (beta-CD) for the detection of cholesterol, was constructed. The PSBTz film with beta-CD was deposited on a graphite electrode by electropolymerization technique to achieve a suitable matrix for enzyme immobilization. Moreover, to justify the immobilization, alkyl chain containing conducting polymer (PSBTz) was designed, synthesized and electrochemically polymerized on the transducer surface. Alkyl chains in the structure of SBTz and hydroxyl groups of beta-CD contributed to effective immobilization while protecting the suitable orientation of the biomolecule. Cholesterol oxidase (ChOx) was covalently immobilized onto the modified surface using N,N'-carbonyldiimidazole (CDI) as the cross-linking agent. After successful immobilization, amperometric biosensor responses were recorded at -0.7 V vs Ag/AgCl in phosphate buffer (pH 7.0). The apparent Michaelis-Menten constant (KMapp), maximum current (I-max), limit of detection (LOD), and sensitivity values were determined: 28.9 mu M, 12.1 mu A, 0.005 mu M, and 5.77 mu A/mu M cm(2), respectively. The fabricated biosensor was characterized using scanning electron microscopy (SEM) and cyclic voltammetry (CV) techniques. Finally, the prepared biosensor was successfully applied for the determination of cholesterol in blood samples.
引用
收藏
页码:18290 / 18300
页数:11
相关论文
共 47 条
[1]   Amphiphilic star copolymers containing cyclodextrin core and their application as nanocarrier [J].
Adeli, Mohsen ;
Zarnegar, Zohre ;
Kabiri, Roya .
EUROPEAN POLYMER JOURNAL, 2008, 44 (07) :1921-1930
[2]  
[Anonymous], 2001, ELECTROCHEMICAL METH
[3]   Immobilization of tyrosinase in polysiloxane/polypyrrole copolymer matrices [J].
Arslan, A ;
Kiralp, S ;
Toppare, L ;
Yagci, Y .
INTERNATIONAL JOURNAL OF BIOLOGICAL MACROMOLECULES, 2005, 35 (3-4) :163-167
[4]   Recent advances in cholesterol biosensor [J].
Arya, Sunil K. ;
Datta, Monika ;
Malhotra, Bansi D. .
BIOSENSORS & BIOELECTRONICS, 2008, 23 (07) :1083-1100
[5]  
Aurelia C., 2006, BIOMACROMOLECULES, V7, P907
[6]   Fused structures in the polymer backbone to investigate the photovoltaic and electrochromic properties of donoracceptor-type conjugated polymers [J].
Cevher, Sevki Can ;
Unlu, Naime Akbasoglu ;
Ozelcaglayan, Ali Can ;
Apaydin, Dogukan Hazar ;
Udum, Yasemin Arslan ;
Toppare, Levent ;
Cirpan, Ali .
JOURNAL OF POLYMER SCIENCE PART A-POLYMER CHEMISTRY, 2013, 51 (09) :1933-1941
[7]   Biosensors based on electropolymerized films: new trends [J].
Cosnier, S .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 377 (03) :507-520
[8]   Electrosynthesized polymers for biosensing [J].
Cosnier, Serge ;
Holzinger, Michael .
CHEMICAL SOCIETY REVIEWS, 2011, 40 (05) :2146-2156
[9]   Redox-Functionalized Graphene Oxide Architecture for the Development of Amperometric Biosensing Platform [J].
Dey, Ramendra Sundar ;
Raj, C. Retna .
ACS APPLIED MATERIALS & INTERFACES, 2013, 5 (11) :4791-4798
[10]   Development of an Amperometric Cholesterol Biosensor Based on Graphene-Pt Nanoparticle Hybrid Material [J].
Dey, Ramendra Sundar ;
Raj, C. Retna .
JOURNAL OF PHYSICAL CHEMISTRY C, 2010, 114 (49) :21427-21433