Comparison of the soft tissue orthodontic analysis measurements between conventional lateral cephalograms and CBCT derived lateral cephalograms.

被引:0
作者
Khanehmasjedi, Mashallah [1 ]
Miresmaili, Amirfarhang [2 ]
Jafari, Sanaz [3 ]
Khanehmasjedi, Samaneh [4 ]
机构
[1] Ahvaz Jundishapur Univ Med Sci, Dept Orthodont, Ahvaz, Iran
[2] Hamedan Dent Fac, Dept Orthodont, Hamadan, Iran
[3] Ahvaz Jundishapur Univ Med Sci, Dept Orthodont, Ahvaz, Iran
[4] Ahvaz Jundishapur Univ Med Sci, Ahvaz, Iran
来源
BIOMEDICAL RESEARCH-INDIA | 2017年 / 28卷 / 03期
关键词
Cephalometry; Cone-beam computed tomography; Soft tissue; COMPUTED-TOMOGRAPHY; CEPHALOMETRIC MEASUREMENTS; RELIABILITY; ERRORS;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Conventional lateral cephalograms are ordered for patients even with available Cone-Beam Computed Tomography (CBCT) radiographs which may increase the patient's radiation exposure. According to past studies landmark identification and hard tissue analysis errors on CBCT-derived lateral cephalograms were comparable to those of conventional lateral cephalograms. According to the soft tissue paradigm, diagnosis and treatment planning are based on the soft tissue goals. The aim of this study was to compare the soft tissue analysis between CBCT-derived and conventional lateral cephalograms of the same patient. Twenty-two patients who had both 12-inch CBCT scan (NewTom 3G) and conventional lateral cephalograms available within a 6-month time period were selected. Landmark identification carried out by two operators at the same time for Dolphin imaging software (v11.2). 8 angular and 11 linear soft tissue variables were measured. Paired t-test comparison of two groups revealed no statistically significant differences between the groups except for inclination of nasal base (P<0.05 was considered significant). CBCT-derived lateral cephalograms can be used for the soft tissue analysis as an alternative to conventional lateral cephalograms, when patient's CBCT volume is already available. This can reduce additional X-ray exposure.
引用
收藏
页码:1087 / 1090
页数:4
相关论文
共 19 条
[1]  
Ackerman J L, 1999, Clin Orthod Res, V2, P49
[2]   THE EFFECT OF PROJECTION ERRORS ON CEPHALOMETRIC LENGTH MEASUREMENTS [J].
AHLQVIST, J ;
ELIASSON, S ;
WELANDER, U .
EUROPEAN JOURNAL OF ORTHODONTICS, 1986, 8 (03) :141-148
[3]   RELIABILITY OF HEAD FILM MEASUREMENTS .1. LANDMARK IDENTIFICATION [J].
BAUMRIND, S ;
FRANTZ, RC .
AMERICAN JOURNAL OF ORTHODONTICS, 1971, 60 (02) :111-&
[4]  
Bholsithi W, 2009, Biomed Imaging Interv J, V5, pe21, DOI 10.2349/biij.5.4.e21
[5]   Image analysis and superimposition of 3-dimensional cone-beam computed tomography models [J].
Cevidanes, Lucia H. S. ;
Styner, Martin A. ;
Proffit, William R. .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2006, 129 (05) :611-618
[6]   Landmark identification errors on cone-beam computed tomography-derived cephalograms and conventional digital cephalograms [J].
Chang, Zwei-Chieng ;
Hu, Fu-Chang ;
Lai, Eddie ;
Yao, Chung-Chen ;
Chen, Mu-Hsiung ;
Chen, Yi-Jane .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2011, 140 (06) :E289-E297
[7]   Comparison of reliability in anatomical landmark identification using two-dimensional digital cephalometrics and three-dimensional cone beam computed tomography in vivo [J].
Chien, P. C. ;
Parks, E. T. ;
Eraso, F. ;
Hartsfield, J. K., Jr. ;
Roberts, W. E. ;
Ofner, S. .
DENTOMAXILLOFACIAL RADIOLOGY, 2009, 38 (05) :262-273
[8]   Comparison between two-dimensional and midsagittal three-dimensional cephalometric measurements of dry human skulls [J].
Damstra, Janalt ;
Fourie, Zacharias ;
Ren, Yijin .
BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2011, 49 (05) :392-395
[9]   Comparison of conventional and cone beam CT synthesized cephalograms [J].
Kumar, V. ;
Ludlow, J. B. ;
Mol, A. ;
Cevidanes, L. .
DENTOMAXILLOFACIAL RADIOLOGY, 2007, 36 (05) :263-269
[10]   In vivo comparison of conventional and cone beam CT synthesized cephalograms [J].
Kumar, Vandana ;
Ludlow, John ;
Cevidanes, Lucia Helena Soares ;
Mol, Andre .
ANGLE ORTHODONTIST, 2008, 78 (05) :873-879