Clinical and radiographic outcomes of minimally invasive percutaneous pedicle screw placement with intraoperative CT (O-arm) image guidance navigation

被引:75
作者
Kim, Terrence T. [1 ]
Drazin, Doniel [2 ]
Shweikeh, Faris [2 ]
Pashman, Robert [1 ]
Johnson, J. Patrick [2 ]
机构
[1] Cedars Sinai Med Ctr, Dept Orthopaed, Los Angeles, CA 90048 USA
[2] Cedars Sinai Med Ctr, Dept Neurosurg, Los Angeles, CA 90048 USA
关键词
minimally invasive surgery; CT navigation; O-arm; pedicle screw; accuracy; OCCUPATIONAL RADIATION-EXPOSURE; LUMBAR INTERBODY FUSION; FACET JOINT VIOLATION; COMPUTED-TOMOGRAPHY; TECHNICAL NOTE; ACCURACY; INSERTION; FIXATION; SPINE; COMPLICATIONS;
D O I
10.3171/2014.1.FOCUS13531
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Object. Intraoperative CT image-guided navigation (IGN) has been increasingly incorporated into minimally invasive spine surgery (MIS). The vast improvement in image resolution and virtual real-time images with CT-IGN has proven superiority over traditional fluoroscopic techniques. The authors describe their perioperative MIS technique using the O-arm with navigation, and they report their postoperative experience, accuracy results, and technical aspects. Methods. A retrospective review of 48 consecutive adult patients undergoing minimally invasive percutaneous posterior spinal fusion with intraoperative CT-IGN between July 2010 and August 2013 at Cedars-Sinai Medical Center was performed. Two surgeons assessed 290 screws in a blinded fashion on intraoperative O-arm images and postoperative CT scans for bony pedicle wall breach. Grade 1 breach was defined to be < 2 mm, Grade 2 breach to be between 2 and 4 mm, and a Grade 3 breach to be > 4 mm. Additionally, anterior vertebral body breach was recorded. Results. Of 290 pedicle screws placed, 280 (96.6%) were in an acceptable position without cortical wall or anterior breach. Of the 10 breaches (3.4%) 5 were lateral (50%), 4 were medial, and 1 was anterior; 90% of breaches were Grade 1-2 and all medial breaches were Grade 1. The one Grade 3 breach was lateral. No vascular or neurological complications were observed intraoperatively, and no significant postoperative complications were noted. The mean clinical follow-up period was 18 months (range 3-39 months). The overall clinical outcomes, measured using the visual analog scale (back pain scores), were improved significantly postoperatively at 3 months compared with preoperatively (visual analog score 6.35 vs 3.57; p < 0.0001). No revision surgery was performed for screw misplacement or neurological deterioration. Conclusions. New CT-IGN with the mobile O-arm scanner has increased the accuracy of pedicle screw/instrumentation placement using MIS techniques. The authors' high (96.6%) accuracy rate in MIS compares favorably with historical published accuracy rates for fluoroscopy-based techniques. Additional advantages of CT-IGN over fluoroscopic imaging methods are lower occupational radiation exposure for the surgical team, reduced need for postoperative imaging, and decreased rates of revision surgery. For now, the authors simply conclude that use of intraoperative CT-IGN is safe and accurate.
引用
收藏
页数:7
相关论文
共 45 条
[1]  
Adibi A, 2012, J RES MED SCI, V17, P434
[2]   O-Arm-based image guidance in minimally invasive spine surgery: Technical note [J].
Baaj, Ali A. ;
Beckman, Joshua ;
Smith, Donald A. .
CLINICAL NEUROLOGY AND NEUROSURGERY, 2013, 115 (03) :342-345
[3]   Percutaneous transarticular atlantoaxial screw fixation using a cannulated screw system and image guidance [J].
Börm, W ;
König, RW ;
Albrecht, A ;
Richter, HP ;
Kast, E .
MINIMALLY INVASIVE NEUROSURGERY, 2004, 47 (02) :111-114
[4]   Accuracy of pedicle screw placement in lumbar vertebrae [J].
Castro, WHM ;
Halm, H ;
Jerosch, J ;
Malms, J ;
Steinbeck, J ;
Blasius, S .
SPINE, 1996, 21 (11) :1320-1324
[5]   Navigated minimally invasive thoracolumbar pedicle screw placement with flat panel 3-D imaging. A feasibility study [J].
Citak, Musa ;
Stubig, Timo ;
Kendoff, Daniel ;
Citak, Mustafa ;
O'Loughlin, Padhraig F. ;
Huefner, Tobias ;
Krettek, Christian .
TECHNOLOGY AND HEALTH CARE, 2010, 18 (02) :101-110
[6]   Application of Intraoperative Computed Tomography With or Without Navigation System in Surgical Correction of Spinal Deformity A Preliminary Result of 59 Consecutive Human Cases [J].
Cui, Geng ;
Wang, Yan ;
Kao, Ting-Hsien ;
Zhang, Yonggang ;
Liu, Zhengsheng ;
Liu, Baowei ;
Li, Jie ;
Zhang, Xifeng ;
Zhu, Shourong ;
Lu, Ning ;
Mao, Keya ;
Wang, Zheng ;
Zhang, Xuesong ;
Yuan, Xincheng ;
Dong, Tianxiang ;
Xiao, Songhua .
SPINE, 2012, 37 (10) :891-900
[7]   The efficacy of minimally invasive discectomy compared with open discectomy: a meta-analysis of prospective randomized controlled trials Clinical article [J].
Dasenbrock, Hormuzdiyar H. ;
Juraschek, Stephen P. ;
Schultz, Lonni R. ;
Witham, Timothy F. ;
Sciubba, Daniel M. ;
Wolinsky, Jean-Paul ;
Gokaslan, Ziya L. ;
Bydon, Ali .
JOURNAL OF NEUROSURGERY-SPINE, 2012, 16 (05) :452-462
[8]   Clinical and radiographic comparison of mini-open transforaminal lumbar interbody fusion with open transforaminal lumbar interbody fusion in 42 patients with long-term follow-up [J].
Dhall, Sanjay S. ;
Wang, Michael Y. ;
Mummaneni, Praveen V. .
JOURNAL OF NEUROSURGERY-SPINE, 2008, 9 (06) :560-565
[9]   The removal of a transdural pedicle screw placed for thoracolumbar spine fracture [J].
Donovan, DJ ;
Polly, DW ;
Ondra, SL .
SPINE, 1996, 21 (21) :2495-2498
[10]   COMPLICATIONS ASSOCIATED WITH THE TECHNIQUE OF PEDICLE SCREW FIXATION - A SELECTED SURVEY OF ABS MEMBERS [J].
ESSES, SI ;
SACHS, BL ;
DREYZIN, V .
SPINE, 1993, 18 (15) :2231-2239