Porous Ti6Al4V alloys with enhanced normalized fatigue strength for biomedical applications

被引:34
作者
Li, Fuping [1 ]
Li, Jinshan [1 ]
Kou, Hongchao [1 ]
Zhou, Lian [1 ]
机构
[1] Northwestern Polytech Univ, State Key Lab Solidificat Proc, Xian 710072, Peoples R China
来源
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS | 2016年 / 60卷
关键词
Titanium alloys; Diffusion bonding; Fatigue; Normalized fatigue strength; BONE IMPLANT APPLICATIONS; COATED TI-6AL-4V ALLOY; COMPRESSIVE BEHAVIOR; TITANIUM; BIOMATERIALS; FABRICATION; COMPATIBILITY;
D O I
10.1016/j.msec.2015.11.074
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
In this paper, porous Ti6Al4V alloys for biomedical applications were fabricated by diffusion bonding of alloy meshes. The compression-compression fatigue behavior was studied. It results that porous Ti6Al4V alloys show enhanced normalized fatigue strength which is in the range of 0.5-0.55 at 106 cycles. The porosity has some effect on the absolute S-N curves but minor effect on the normalized S-N curves. The relationship between strain per cycle and number of cycles shows three distinct stages and the value of strain per cycle is constant in stage II. The reasons for the higher normalized fatigue strength of porous Ti6Al4V alloys are discussed based on the fatigue crack initiation and propagation. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:485 / 488
页数:4
相关论文
共 22 条
[1]   MECHANICAL-PROPERTIES AND BIOMECHANICAL COMPATIBILITY OF POROUS TITANIUM FOR DENTAL IMPLANTS [J].
ASAOKA, K ;
KUWAYAMA, N ;
OKUNO, O ;
MIURA, I .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1985, 19 (06) :699-713
[2]   Fabrication of porous titanium scaffolds by stack sintering of microporous titanium spheres produced with centrifugal granulation technology [J].
Chen, Hongjie ;
Wang, Chunli ;
Zhu, Xiangdong ;
Zhang, Kai ;
Fan, Yujiang ;
Zhang, Xingdong .
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2014, 43 :182-188
[3]   THE EFFECT OF POST-SINTERING HEAT-TREATMENTS ON THE FATIGUE PROPERTIES OF POROUS COATED TI-6AL-4V ALLOY [J].
COOK, SD ;
THONGPREDA, N ;
ANDERSON, RC ;
HADDAD, RJ .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1988, 22 (04) :287-302
[4]   FATIGUE PROPERTIES OF CARBON-COATED AND POROUS-COATED TI-6AL-4V ALLOY [J].
COOK, SD ;
GEORGETTE, FS ;
SKINNER, HB ;
HADDAD, RJ .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1984, 18 (05) :497-512
[5]   Osteoblast response to porous titanium and biomimetic surface: In vitro analysis [J].
do Prado, Renata Falchete ;
de Oliveira, Femanda Saraiva ;
Nascimento, Rodrigo Dias ;
Reis de Vasconcellos, Luana Marotta ;
Carvalho, Yasmin Rodarte ;
Alves Cairo, Carlos Alberto .
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2015, 52 :194-203
[6]   Osteoinduction of porous Ti implants with a channel structure fabricated by selective laser melting [J].
Fukuda, A. ;
Takemoto, M. ;
Saito, T. ;
Fujibayashi, S. ;
Neo, M. ;
Pattanayak, Deepak K. ;
Matsushita, T. ;
Sasaki, K. ;
Nishida, N. ;
Kokubo, T. ;
Nakamura, T. .
ACTA BIOMATERIALIA, 2011, 7 (05) :2327-2336
[7]   Ti based biomaterials, the ultimate choice for orthopaedic implants - A review [J].
Geetha, M. ;
Singh, A. K. ;
Asokamani, R. ;
Gogia, A. K. .
PROGRESS IN MATERIALS SCIENCE, 2009, 54 (03) :397-425
[8]   Compression-compression fatigue of selective electron beam melted cellular titanium (Ti-6Al-4V) [J].
Hrabe, Nikolas W. ;
Heinl, Peter ;
Flinn, Brian ;
Koerner, Carolin ;
Bordia, Rajendra K. .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2011, 99B (02) :313-320
[9]   Fatigue crack growth behavior of titanium foams for medical applications [J].
Kashef, Sadaf ;
Asgari, Alireza ;
Hilditch, Timothy B. ;
Yan, Wenyi ;
Goel, Vijay K. ;
Hodgson, Peter D. .
MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 2011, 528 (03) :1602-1607
[10]  
Li F., 2015, J MAT SCI T IN PRESS