The enantioseparation of amino acids on a teicoplanin chiral stationary phase using non-aqueous mobile phases after pre-column derivatization with sulfur-containing reagents: the considerations of mobile phase composition and analyte structure variation on resolution enhancement

被引:16
作者
Chen, S. [1 ]
机构
[1] Natl Chiayi Univ, Dept Appl Chem, Chiayi 600, Taiwan
关键词
column liquid chromatography; enantioresolution; amino acids; sulfur-containing reagents; teicoplanin; non-aqueous mobile phase;
D O I
10.1002/bmc.587
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Amino acids were derivatized with sulfur-containing reagents in alkaline medium and enantioresolved by HPLC on a teicoplanin chiral stationary phase. Much better resolution was achieved using methanol-based mobile phase compared with elution with acetonitrile-based solvent mixture. The value of selectivity factor for many derivatives examined in the study can be easily several tenths of 100 or even exceed 100 in some cases. This magnitude of resolution is suitable for the preparative-scale application of isolating alpha-amino acid enantiomers in the derivatized form using a short column. The resolution is believed to be a result of the hydrogen bonding and steric hindrance by the nitrogen and sulfur atoms from the isothiocyanatyl fragment of the reagent, respectively, and is enhanced as the fragment is structurally phenylated (e.g. 2,4-difluorophenyl isothiocyanate and others examined in this study). The enhancement is even more significant if the aromatic moiety of the reagent becomes more acidic through halogenation with chlorine or fluorine for the stronger pi-pi interaction. However, this type of enhancement is offset to some extent and sometimes obscured by a chlorinated reagent that is relatively large in size as compared with the fluorinated one. Judging from the chromatographic data and the elution profile, the mechanisms leading to the resolutions are believed to be different under the elution of polar-organic mobile phases (i.e. methanol- and acetonitrile-based mobile phases). Copyright (c) 2005 John Wiley & Sons, Ltd.
引用
收藏
页码:718 / 728
页数:11
相关论文
共 25 条
[1]   A NEW APPROACH FOR THE DIRECT RESOLUTION OF RACEMIC BETA-ADRENERGIC BLOCKING-AGENTS BY HPLC [J].
ARMSTRONG, DW ;
CHEN, S ;
CHANG, C ;
CHANG, S .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1992, 15 (03) :545-556
[2]   MACROCYCLIC ANTIBIOTICS AS A NEW CLASS OF CHIRAL SELECTORS FOR LIQUID-CHROMATOGRAPHY [J].
ARMSTRONG, DW ;
TANG, YB ;
CHEN, SS ;
ZHOU, YW ;
BAGWILL, C ;
CHEN, JR .
ANALYTICAL CHEMISTRY, 1994, 66 (09) :1473-1484
[3]   HIGHLY ENANTIOSELECTIVE CAPILLARY ELECTROPHORETIC SEPARATIONS WITH DILUTE-SOLUTIONS OF THE MACROCYCLIC ANTIBIOTIC RISTOCETIN-A [J].
ARMSTRONG, DW ;
GASPER, MP ;
RUNDLETT, KL .
JOURNAL OF CHROMATOGRAPHY A, 1995, 689 (02) :285-304
[4]   USE OF A MACROCYCLIC ANTIBIOTIC, RIFAMYCIN-B, AND INDIRECT DETECTION FOR THE RESOLUTION OF RACEMIC AMINO-ALCOHOLS BY CE [J].
ARMSTRONG, DW ;
RUNDLETT, K ;
REID, GL .
ANALYTICAL CHEMISTRY, 1994, 66 (10) :1690-1695
[5]   Facile liquid chromatographic enantioresolution of native amino acids and peptides using a teicoplanin chiral stationary phase [J].
Berthod, A ;
Liu, YB ;
Bagwill, C ;
Armstrong, DW .
JOURNAL OF CHROMATOGRAPHY A, 1996, 731 (1-2) :123-137
[6]   Enantiomeric separation by HPLC of 1,4-dihydropyridines with vancomycin as chiral selector [J].
Boatto, G ;
Nieddu, M ;
Faedda, MV ;
de Caprariis, P .
CHIRALITY, 2003, 15 (06) :494-497
[7]   EVALUATION OF A NEW POLAR ORGANIC HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC MOBILE PHASE FOR CYCLODEXTRIN-BONDED CHIRAL STATIONARY PHASES [J].
CHANG, SC ;
REID, GL ;
CHEN, S ;
CHANG, CD ;
ARMSTRONG, DW .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1993, 12 (04) :144-153
[8]   The HPLC stereoselective resolution of N-2,4-dinitrophenylated (DNP) amine-containing enantiomers on teicoplanin bonded phase using the methanol-based mobile phase [J].
Chen, S .
CHROMATOGRAPHIA, 2004, 59 (3-4) :173-180
[9]  
CHEN S, 1994, J LIQ CHROMATOGR, V17, P485
[10]  
CHEN S, 2005, IN PRESS BIOMEDICAL