Washing-Free Heterogeneous Immunosensor Using Proximity-Dependent Electron Mediation between an Enzyme Label and an Electrode

被引:45
作者
Dutta, Gorachand [1 ]
Kim, Sinyoung [2 ]
Park, Seonhwa [1 ]
Yang, Haesik [1 ]
机构
[1] Pusan Natl Univ, Inst Funct Mat, Dept Chem & Chem, Pusan 609735, South Korea
[2] Yonsei Univ, Coll Med, Dept Lab Med, Seoul 135720, South Korea
基金
新加坡国家研究基金会;
关键词
IMMUNOASSAY;
D O I
10.1021/ac5006487
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Washing processes, essential in most heterogeneous labeled assays, have been a big hurdle in simplifying the detection procedure and reducing assay time. Nevertheless, less attention has been paid to washing-free heterogeneous labeled assays. We report a purely washing-free immunosensor that allows fast, sensitive, and single-step detection of prostate-specific antigen in serum with low interference. Proximity-dependent electron mediation of ferrocenemethanol (Fc) between an indium tin oxide (ITO) electrode and a glucose-oxidase (GOx) label allows us to discriminate between a bound and an unbound label: a bound label offers faster electron mediation than an unbound one. The electrooxidation of Fc at a low applied potential (0.13 V vs Ag/AgCl) and a low electrocatalytic ITO electrode and the oxidation of L-ascorbic acid by L-ascorbate oxidase minimize the effect of the interfering species. With a high concentration of glucose (200 mM), the signal and background levels are hardly dependent on the glucose-concentration variation in the sample. The washing-free immunosensor can detect a concentration of ca. 1 pg/mL for mouse IgG in phosphate-buffered saline and a concentration of ca. 10 pg/mL for prostate-specific antigen spiked in female serum after an incubation period of 10 min. The concentrations measured with actual clinical serum samples are in good agreement with the concentrations measured with a commercial instrument, which renders the washing-free heterogeneous immunosensor appealing for practical use.
引用
收藏
页码:4589 / 4595
页数:7
相关论文
共 26 条
[1]   An interference-free and rapid electrochemical lateral-flow immunoassay for one-step ultrasensitive detection with serum [J].
Akanda, Md. Rajibul ;
Joung, Hyou-Arm ;
Tamilavan, Vellaiappillai ;
Park, Seonhwa ;
Kim, Sinyoung ;
Hyun, Myung Ho ;
Kim, Min-Gon ;
Yang, Haesik .
ANALYST, 2014, 139 (06) :1420-1425
[2]   Towards immunoassay in whole blood: separationless sandwich-type electrochemical immunoassay based on in-situ generation of the substrate of the labeling enzyme [J].
Campbell, CN ;
de Lumley-Woodyear, T ;
Heller, A .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 364 (1-2) :165-169
[3]   FERROCENE-MEDIATED ENZYME ELECTRODE FOR AMPEROMETRIC DETERMINATION OF GLUCOSE [J].
CASS, AEG ;
DAVIS, G ;
FRANCIS, GD ;
HILL, HAO ;
ASTON, WJ ;
HIGGINS, IJ ;
PLOTKIN, EV ;
SCOTT, LDL ;
TURNER, APF .
ANALYTICAL CHEMISTRY, 1984, 56 (04) :667-671
[4]   Discrimination of Breast Cancer by Measuring Prostate-Specific Antigen Levels in Women's Serum [J].
Chang, Ying-Feng ;
Hung, Shuo-Hui ;
Lee, Yi-Jang ;
Chen, Ran-Chou ;
Su, Li-Chen ;
Lai, Chao-Sung ;
Chou, Chien .
ANALYTICAL CHEMISTRY, 2011, 83 (13) :5324-5328
[5]   Control of electron transfer kinetics at glassy carbon electrodes by specific surface modification [J].
Chen, PH ;
McCreery, RL .
ANALYTICAL CHEMISTRY, 1996, 68 (22) :3958-3965
[6]   The influence of structure in the reaction of electrochemically generated ferrocenium derivatives with reduced glucose oxidase [J].
Forrow, NJ ;
Sanghera, GS ;
Walters, SJ .
JOURNAL OF THE CHEMICAL SOCIETY-DALTON TRANSACTIONS, 2002, (16) :3187-3194
[7]   Outer-Sphere Redox Couples as Shuttles in Dye-Sensitized Solar Cells. Performance Enhancement Based on Photoelectrode Modification via Atomic Layer Deposition [J].
Hamann, Thomas W. ;
Farha, Omar K. ;
Hupp, Joseph T. .
JOURNAL OF PHYSICAL CHEMISTRY C, 2008, 112 (49) :19756-19764
[8]   Elimination of electrochemical interferences in glucose biosensors [J].
Jia, Wen-Zhi ;
Wang, Kang ;
Xia, Xing-Hua .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2010, 29 (04) :306-318
[9]   Separation-free electrochemical immunosensor strategies [J].
Killard, AJ ;
Smyth, MR .
ANALYTICAL LETTERS, 2000, 33 (08) :1451-1465
[10]  
Kwon S., 2012, 16 INT C MIN SYST CH, P725