A weightbearing technique for the measurement of ankle joint dorsiflexion with the knee extended is reliable

被引:97
作者
Munteanu, Shannon E. [1 ,2 ]
Strawhorn, Andrea B.
Landorf, Karl B. [1 ,2 ]
Bird, Adam R. [1 ,2 ]
Murley, George S. [1 ,2 ]
机构
[1] La Trobe Univ, Fac Hlth Sci, Dept Podiatry, Bundoora, Vic 3086, Australia
[2] La Trobe Univ, Fac Hlth Sci, Musculoskeletal Res Ctr, Bundoora, Vic 3086, Australia
关键词
Ankle joint; Reliability; Range of motion; GONIOMETRIC MEASUREMENTS; RELIABILITY; RANGE; MOTION; FOOT; INJURIES; INCREASE; MUSCLES; RISK;
D O I
10.1016/j.jsams.2007.06.009
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Measurement of ankle joint dorsiflexion is routinely undertaken by clinicians who manage tower limb musculoskeletal pathology. This study aimed to determine the reliability of a technique to measure ankle joint dorsiflexion in a weightbearing position with the knee extended. Four raters with varying clinical experience measured ankle joint dorsiflexion in a weightbearing position with the knee extended on 30 asymptomatic participants. Measurements occurred on two occasions, 1 week apart using (i) a digital inclinometer and (ii) a clear acrylic plate apparatus. Intraclass correlation coefficients (ICCs) and 95% limits of agreement (LOAs) were calculated. Intra-rater reliability of the experienced raters was high for both the digital inclinometer (average ICC = 0.88, average 95% LOA = -6.6 degrees to 4.8 degrees) and the clear acrylic plate apparatus (average ICC = 0.89, average 95% LOA = -7.2 degrees to 4.3 degrees). Intra-rater reliability of the inexperienced rater was good to high for both the digital inclinometer (ICC = 0.77, 95% LOA = -9.1 degrees to 8.3 degrees) and the clear acrylic plate apparatus (ICC = 0.89, 95% LOA = -8.1 degrees to 4.6 degrees). Inter-rater reliability was high for both the digital inclinometer (ICC = 0.95, 95% LOA = -5.7 degrees to 5.7 degrees) and the clear acrylic plate apparatus (ICC = 0.97, 95% LOA = -4.7 degrees to 4.7 degrees). Measurements of ankle dorsiflexion in a weightbearing position with the knee extended can be performed reliably by experienced and inexperienced raters. However, the reliability of this measurement technique needs to be interpreted in the context of the purpose for which the measurement is intended. (C) 2007 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:54 / 59
页数:6
相关论文
共 25 条
[1]  
Agosta J, 1999, AUST J PODIATR MED, V33, P13
[2]  
Bennell Kim L, 1998, Aust J Physiother, V44, P175
[3]   Measuring agreement in method comparison studies [J].
Bland, JM ;
Altman, DG .
STATISTICAL METHODS IN MEDICAL RESEARCH, 1999, 8 (02) :135-160
[4]  
Burns J., 2005, Foot, V15, P91, DOI [10.1016/j.foot.2005.03.003, DOI 10.1016/J.FOOT.2005.03.003, DOI 10.1016/J.F00T.2005.03.003]
[5]   Isolated gastrocnemius tightness [J].
DiGiovanni, CW ;
Kuo, R ;
Tejwani, N ;
Price, R ;
Hansen, ST ;
Cziernecki, J ;
Sangeorzan, BJ .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (06) :962-970
[6]  
EKSTRAND J, 1982, ARCH PHYS MED REHAB, V63, P171
[7]   Reliability of the foot posture index and traditional measures of foot position [J].
Evans, AM ;
Copper, AW ;
Scharfbillig, RW ;
Scutter, SD ;
Williams, MT .
JOURNAL OF THE AMERICAN PODIATRIC MEDICAL ASSOCIATION, 2003, 93 (03) :203-213
[8]   Predictors of lower extremity injuries at the community level of Australian football [J].
Gabbe, BJ ;
Finch, CF ;
Wajswelner, H ;
Bennell, KL .
CLINICAL JOURNAL OF SPORT MEDICINE, 2004, 14 (02) :56-63
[9]   Effects of an eight-week stretching program on the passive-elastic properties and function of the calf muscles of older women [J].
Gajdosik, RL ;
Vander Linden, DW ;
McNair, PJ ;
Williams, AK ;
Riggin, TJ .
CLINICAL BIOMECHANICS, 2005, 20 (09) :973-983
[10]   The effect of foot structure and range of motion on musculoskeletal overuse injuries [J].
Kaufman, KR ;
Brodine, SK ;
Shaffer, RA ;
Johnson, CW ;
Cullison, TR .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1999, 27 (05) :585-593