Influencing Parameters on the Microwave-Based Soot Load Determination of Diesel Particulate Filters

被引:10
作者
Feulner, Markus [1 ]
Seufert, Florian [1 ]
Mueller, Andreas [1 ]
Hagen, Gunter [1 ]
Moos, Ralf [1 ]
机构
[1] Univ Bayreuth, Dept Funct Mat, BERC, Zentrum Energietech ZET, D-95440 Bayreuth, Germany
关键词
Diesel particulate filter (DPF); On-board diagnostics; Exhaust gas aftertreatment; Microwave; Cavity perturbation; CATALYST;
D O I
10.1007/s11244-016-0626-7
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
Diesel Particulate Filters (DPF) are an essential part of today's diesel exhaust gas aftertreatment systems. For an effective filter regeneration strategy, the precise knowledge of the actual trapped soot mass is essential. Besides the state-of-the-art technology of determining the soot load via pressure drop and/or model-based, a microwave-based method enables direct and in situ soot load detection. Thereby, an electric field is impressed into the filter housing and the power transmission is measured, which correlates with the soot load. In this study, influencing parameters, especially temperature and humidity, are examined and compared to the sensitivity towards soot accumulation. Measurements were conducted in a laboratory test bench with a filter-core, which had been previously loaded with soot in an engine dynamometer. While humidity does not have a notable effect, the influence of temperature needs to be considered for real world application. Finally, a complete filter regeneration of the DPF-core in the laboratory test bench could be monitored with the microwave-based system. The carbon balance-derived burned soot mass coincides very well with the microwave derived transmission parameter.
引用
收藏
页码:374 / 380
页数:7
相关论文
共 18 条
[1]  
Feulner M., 2013, P 16 INT C SENS MEAS, DOI [10.5162/sensor2013/P4.1, DOI 10.5162/SENSOR2013/P4.1]
[2]  
Feulner M, 2014, P 18 ETH C COMB GEN
[3]   In-Operation Monitoring of the Soot Load of Diesel Particulate Filters: Initial Tests [J].
Feulner, Markus ;
Hagen, Gunter ;
Piontkowski, Andreas ;
Mueller, Andreas ;
Fischerauer, Gerhard ;
Brueggemann, Dieter ;
Moos, Ralf .
TOPICS IN CATALYSIS, 2013, 56 (1-8) :483-488
[4]   Catalyst State Observation via the Perturbation of a Microwave Cavity Resonator [J].
Fischerauer, Gerhard ;
Spoerl, Matthias ;
Gollwitzer, Andreas ;
Wedemann, Marion ;
Moos, Ralf .
FREQUENZ, 2008, 62 (7-8) :180-184
[5]   Sensing the soot load in automotive diesel particulate filters by microwave methods [J].
Fischerauer, Gerhard ;
Foerster, Martin ;
Moos, Ralf .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2010, 21 (03)
[6]   Determination of the NOx Loading of an Automotive Lean NOx Trap by Directly Monitoring the Electrical Properties of the Catalyst Material Itself [J].
Fremerey, Peter ;
Reiss, Sebastian ;
Geupel, Andrea ;
Fischerauer, Gerhard ;
Moos, Ralf .
SENSORS, 2011, 11 (09) :8261-8280
[7]  
Hansson J., 2012, THESIS
[8]  
Kato K, 2014, P 18 ETH C COMB GEN
[9]  
Masoudi M, 2014, SOOT PM SENSORS DIES
[10]   Microwave-Based Catalyst State Diagnosis - State of the Art and Future Perspectives [J].
Moos, Ralf .
SAE INTERNATIONAL JOURNAL OF ENGINES, 2015, 8 (03) :1240-1245