A mobile tomographic gamma camera system for acute studies

被引:9
作者
Dale, S [1 ]
Holmberg, M [1 ]
Larsson, H [1 ]
Persson, M [1 ]
Ribbe, T [1 ]
Elmqvist, H [1 ]
Bone, D [1 ]
Brodin, LA [1 ]
Lindstrom, C [1 ]
Jorfeldt, L [1 ]
机构
[1] KAROLINSKA HOSP,THORAC PHYSIOL DEPT,S-10401 STOCKHOLM,SWEDEN
基金
瑞典研究理事会;
关键词
acute studies; gamma camera; mobile system tomography;
D O I
10.1109/23.568806
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A mobile tomographic gamma camera system, called Cardiotom Mark 1, has been developed for imaging the myocardium and other small organs, The Cardiotom system is based on a tomographic technique, ectomography, which is a limited view angle method using a rotating slant hole collimator (RSHC) and a stationary detector to produce projection images, This enables the ectomographic system to be implemented as a mobile system, With the system developed, almost 200 perfusion studies have been performed, The system is based on a second-hand detector and a 30 degrees RSHC, By segmenting the collimator, total system efficiency is increased and acquisition time can be reduced by a factor equal to the number of segments, The system developed is PC-based and totally self-contained with data acquisition, reconstruction, and image presentation, The mobility of the system and the fact that the examination requires no patient cooperation enable acute studies of myocardial perfusion in the critically ill patient, either in the intensive care unit or the emergency room, A mobile system with three-dimensional imaging can offer new possibilities in cardiological research and diagnosis.
引用
收藏
页码:199 / 203
页数:5
相关论文
共 50 条
  • [1] Validation of an iterative reconstruction for a mobile tomographic gamma camera system -: The Cardiotom
    Valastyan, I.
    Bone, D.
    Brodin, L.-A.
    Elmqvist, H.
    Lagerlof, J.
    Kerek, A.
    Molnar, J.
    Novak, D.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (02) : 1097 - 1100
  • [2] Impact of Mobile Phone Interference on Gamma Camera Performance
    Dowling, Melissa
    O'Loughlin, Samantha
    Currie, Geoffrey M.
    JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2019, 50 (01) : 136 - 141
  • [3] INTELLIGENT DECISION SUPPORT SYSTEM FOR FUNCTIONAL DIAGNOSTICS WITH GAMMA CAMERA
    Moskalenko, V. V.
    Ryzhova, A. S.
    Dovbish, A. S.
    RADIO ELECTRONICS COMPUTER SCIENCE CONTROL, 2015, 4 : 52 - 58
  • [4] Performance of Semiconductor Gamma-Camera System with CdZnTe Detector
    Ogawa, K.
    Ishikawa, T.
    Shuto, K.
    Motomura, N.
    Kobayashi, H.
    4TH EUROPEAN CONFERENCE OF THE INTERNATIONAL FEDERATION FOR MEDICAL AND BIOLOGICAL ENGINEERING, 2009, 22 (1-3): : 829 - 831
  • [5] The HICAM Gamma Camera
    Fiorini, C.
    Busca, P.
    Peloso, R.
    Abba, A.
    Geraci, A.
    Bianchi, C.
    Poli, G. L.
    Virotta, G.
    Erlandsson, K.
    Hutton, B. F.
    Lechner, P.
    Soltau, H.
    Strueder, L.
    Pedretti, A.
    Van Mullekom, P.
    Ottobrini, L.
    Lucignani, G.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2012, 59 (03) : 537 - 544
  • [6] Monitoring system for isolated limb perfusion based on a portable gamma camera
    Orero, A.
    Vidal-Sicart, S.
    Roe, N.
    Muxi, A.
    Rubi, S.
    Duch, J.
    Rull, R.
    Pavon, N.
    Pons, F.
    Pavia, J.
    NUKLEARMEDIZIN-NUCLEAR MEDICINE, 2009, 48 (04): : 166 - 172
  • [7] A flat-panel-based mini gamma camera for lymph nodes studies
    Fernández, MM
    Benlloch, JM
    Cerdá, J
    Escat, B
    Giménez, EN
    Giménez, M
    Lerche, CW
    Martínez, J
    Pavón, N
    Sánchez, F
    Sebastià, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 527 (1-2) : 92 - 96
  • [8] Device for diagnosis of gamma camera
    Oramas Polo, Ivon
    REVISTA CUBANA DE INGENIERIA, 2019, 10 (02): : 16 - 23
  • [9] CZT gamma camera for scintimammography
    Blevis, Ira M.
    O'Connor, M. K.
    Keidar, Z.
    Pansky, A.
    Altman, H.
    Hugg, J. W.
    PHYSICA MEDICA, 2006, 21 : 56 - 59
  • [10] Development of an all-in-one gamma camera/CCD system for safeguard verification
    Kim, Hyun-Il
    An, Su Jung
    Chung, Yong Hyun
    Kwak, Sung-Woo
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2014, 65 (12) : 2013 - 2016