Simultaneous determination of aliphatic, aromatic and heterocyclic biogenic amines without derivatization by capillary electrophoresis and application in beer analysis

被引:51
作者
He, Lili [1 ]
Xu, Zhongqi [1 ]
Hirokawa, Takeshi [2 ]
Shen, Li [1 ]
机构
[1] Donghua Univ, Coll Chem Chem Engn & Biotechnol, Shanghai, Peoples R China
[2] Hiroshima Univ, Appl Chem, Dept Chem & Chem Engn, Grad Sch Engn, Hiroshima 730, Japan
关键词
Capillary electrophoresis; Biogenic amines; UV absorbing probe; Imidazole; Beer; INDIRECT UV-DETECTION; INDIRECT FLUORESCENCE DETECTION; INDIRECT PHOTOMETRIC DETECTION; ZONE-ELECTROPHORESIS; BACKGROUND ELECTROLYTES; AMPEROMETRIC DETECTION; FISH; POLYAMINES; URINE; FOODS;
D O I
10.1016/j.chroma.2016.12.067
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Biogenic amines (BAs) play significant roles in indicating human health or food quality. Aiming to simultaneously determine three structures (aliphatic, aromatic and heterocyclic) of underivatized BAs, we explored a simple and rapid capillary electrophoresis (CE) method only coupled with conventional UV detector for the separation of thirteen key BAs. The strategy is to choose a UV absorbing probe as co-ion in the background electrolyte (BGE), and different BAs could be characterized by positive or negative peaks according to the fact that their UV absorptivity coefficients at a certain wavelength are better or worse than that of the UV absorbing probe. After the detailed investigation of critical parameters as pH, the concentration of Imidazole (Im) and alpha-cyclodextrin (alpha-CD), the optimized BGE consisted of 12.0 mmol/L Im as the UV probe and 10.0 mmol/L alpha-CD as the additive (at pH 4.50 adjusted with acetic acid). With such condition, the targets of thirteen BAs were baseline separated in 9.0 min and appeared at nine positive peaks and four negative peaks at 200 nm. The obtained LODs and LOQs (S/N = 3 or 10) were in the range of 0.36-3.67 and 1.2-12.2 mu mol/L, respectively. The interday RSDs of migration time and peak area were less than 0.7% and 4.7% (n = 6), respectively. To the best of our knowledge, this is the first report on separating diverse structures of BAs by using Im as UV absorbing probe. The thirteen BAs were simultaneously detected by direct and indirect UV detection in a CE process. To verify the applicability, this method was used to analyze BAs in commercial beer samples. The recoveries of all BAs except carnosine (not identified by the interference) ranged from 70.4 to 119.6%, and four aliphatic and aromatic amines were satisfactorily identified and quantified. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:109 / 114
页数:6
相关论文
共 37 条
[1]   Selective and rapid determination of biogenic amines by capillary zone electrophoresis [J].
Arce, L ;
Rios, A ;
Valcarcel, M .
CHROMATOGRAPHIA, 1997, 46 (3-4) :170-176
[2]   Direct determination of biogenic amines in wine by integrating continuous flow clean-up and capillary electrophoresis with indirect UV detection [J].
Arce, L ;
Ríos, A ;
Valcárcel, M .
JOURNAL OF CHROMATOGRAPHY A, 1998, 803 (1-2) :249-260
[3]  
Beard NP, 2002, ELECTROPHORESIS, V23, P1722, DOI 10.1002/1522-2683(200206)23:11<1722::AID-ELPS1722>3.0.CO
[4]  
2-W
[5]   Calibrationless quantitative analysis by indirect UV absorbance detection in capillary zone electrophoresis: The concept of the conversion factor [J].
Beckers, JL ;
Bocek, P .
ELECTROPHORESIS, 2004, 25 (02) :338-343
[6]  
Beckers JL, 2002, ELECTROPHORESIS, V23, P1947, DOI 10.1002/1522-2683(200206)23:12<1947::AID-ELPS1947>3.0.CO
[7]  
2-M
[8]   The preparation of background electrolytes capillary zone electrophoresis: Golden rules and pitfalls [J].
Beckers, JL ;
Bocek, P .
ELECTROPHORESIS, 2003, 24 (03) :518-535
[9]   BIOGENIC-AMINE METABOLISM IN TOURETTE SYNDROME [J].
BUTLER, IJ ;
KOSLOW, SH ;
SEIFERT, WE ;
CAPRIOLI, RM ;
SINGER, HS .
ANNALS OF NEUROLOGY, 1979, 6 (01) :37-39
[10]   Analytical potential of 6-oxy-(N-succinimidylacetate)-9-(2′-methoxycarbonyl) fluorescein for the determination of amino compounds by capillary electrophoresis with laser-induced fluorescence detection [J].
Cao, LW ;
Wang, H ;
Zhang, HS .
ELECTROPHORESIS, 2005, 26 (10) :1954-1962