Self-Sensing Control of Open-End Winding PMSMs Fed by an Asymmetrical Hybrid Multilevel Inverter

被引:3
作者
Foti, Salvatore [1 ]
Testa, Antonio [1 ]
Scelba, Giacomo [2 ]
De Caro, Salvatore [1 ]
Scarcella, Giuseppe [2 ]
机构
[1] Univ Messina, Dept Engn DI, I-98166 Messina, Italy
[2] Univ Catania, Dept Elect Elect & Comp Engn DIEEI, I-95123 Catania, Italy
关键词
multilevel inverter; Open-end Winding; sensorless motor drive; low frequency modulation; high efficiency; MOTOR DRIVE; FLUX;
D O I
10.3390/en15093166
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The paper presents a self-sensing control technique for a special type of multilevel motor drive featuring an Open-end Winding Permanent-Magnet Synchronous Motor fed on one side by a main multilevel inverter (MLI) and on the other side by an auxiliary two-level inverter (TLI). In order to minimize the power losses, the MLI manages the machine active power operating at a low-switching frequency. The TLI instead acts as an active power filter and operates at a higher switching frequency and a lower DC-Bus voltage than the MLI. The current control task is shared between the two inverters, as a predictive action is exerted by the MLI, while a feedback action is accomplished by the TLI. Common sensorless rotor position estimation techniques cannot be straightforwardly applied on such a system, due to the particular drive structure. Therefore, a specific technique has been carried out, able to ensure satisfactory efficiency and control performance in all the operating speed ranges by optimally exploiting the different features of the two inverters. Simulation and experimental results confirm the effectiveness of the proposed approach.
引用
收藏
页数:16
相关论文
共 34 条
[1]  
Alves J.A., 2009, PULSE, V6, P8
[2]   GENERALIZED STRUCTURE OF A MULTILEVEL PWM INVERTER [J].
BHAGWAT, PM ;
STEFANOVIC, VR .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1983, 19 (06) :1057-1069
[3]  
Cacciato M., 1997, P 1997 IEEE IND APPL, V1, P714
[4]   Slip frequency detection for indirect field-oriented control drives [J].
Consoli, A ;
Scarcella, G ;
Testa, A .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2004, 40 (01) :194-201
[5]  
De Caro S, 2016, IEEE ENER CONV
[6]   Using multiple saliencies for the estimation of flux, position, and velocity in AC machines [J].
Degner, MW ;
Lorenz, RD .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1998, 34 (05) :1097-1104
[7]  
Dev ShuklaR., 2014, 2014 Australasian Universities Power Engineering Conference (AUPEC), P1
[8]   New Optimal Pulsewidth Modulation for Single DC-Link Dual-Inverter Fed Open-End Stator Winding Induction Motor Drive [J].
Edpuganti, Amarendra ;
Rathore, Akshay Kumar .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2015, 30 (08) :4386-4393
[9]  
Fot S., 2018, P 2018 IEEE 9 INT S, P155
[10]  
Foti S., 2015, P 2015 INT C RENEWAB, P245