Extensive Peptide Fractionation and y1 Ion-Based Interference Detection Method for Enabling Accurate Quantification by Isobaric Labeling and Mass Spectrometry

被引:89
作者
Niu, Mingming [1 ,2 ,5 ]
Cho, Ji-Hoon [3 ]
Kodali, Kiran [3 ]
Pagala, Vishwajeeth [3 ]
High, Anthony A. [3 ]
Wang, Hong [1 ,2 ,6 ]
Wu, Zhiping [1 ,2 ]
Li, Yuxin [1 ,2 ]
Bi, Wenjian [4 ]
Zhang, Hui [4 ]
Wang, Xusheng [3 ]
Zou, Wei [5 ]
Peng, Junmin [1 ,2 ,3 ]
机构
[1] St Jude Childrens Res Hosp, Dept Biol Struct, Memphis, TN 38105 USA
[2] St Jude Childrens Res Hosp, Dept Dev Neurobiol, Memphis, TN 38105 USA
[3] St Jude Childrens Res Hosp, St Jude Prote Facil, Memphis, TN 38105 USA
[4] St Jude Childrens Res Hosp, Dept Biostat, Memphis, TN 38105 USA
[5] Heilongjiang Univ Chinese Med, Harbin 150040, Heilongjiang, Peoples R China
[6] Univ Tennessee, Integrated Biomed Sci Program, Hlth Sci Ctr, Memphis, TN 38163 USA
基金
美国国家卫生研究院;
关键词
SYSTEMATIC OPTIMIZATION; PROTEOME QUANTIFICATION; SHOTGUN PROTEOMICS; RATIO COMPRESSION; HUMAN BRAIN; CHROMATOGRAPHY; CANCER; SCALE; PHOSPHOPROTEOME; IDENTIFICATION;
D O I
10.1021/acs.analchem.6b04415
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Isobaric labeling quantification by mass spectrometry (MS) has emerged as a powerful technology for multiplexed large-scale protein profiling, but measurement accuracy in complex mixtures is confounded by the interference from coisolated ions, resulting in ratio compression. Here we report that the ratio compression can be essentially resolved by the combination of pre-MS peptide fractionation, MS2-based interference detection, and post-MS computational interference correction. To recapitulate the complexity of biological samples, we pooled tandem mass tag (TMT)-labeled Escherichia coli peptides at 1:3:10 ratios and added in 10-fold more rat peptides as background, followed by the analysis of two-dimensional liquid chromatography (LC) MS/MS. Systematic investigation shows that quantitative interference was impacted by LC fractionation depth, MS isolation window, and peptide loading amount. Exhaustive fractionation (320 X 4 h) can nearly eliminate the interference and achieve results comparable to the MS3-based method. Importantly, the interference in MS2 scans can be estimated by the intensity of contaminated yi product ions, and we thus developed an algorithm to correct reporter ion ratios of tryptic peptides. Our data indicate that intermediate fractionation (40 X 2 h) and yi ion-based correction allow accurate and deep TMT profiling of more than 10 000 proteins, which represents a straightforward and affordable strategy in isobaric labeling proteomics.
引用
收藏
页码:2956 / 2963
页数:8
相关论文
共 40 条
[1]   Mass-spectrometric exploration of proteome structure and function [J].
Aebersold, Ruedi ;
Mann, Matthias .
NATURE, 2016, 537 (7620) :347-355
[2]   Evaluation and Improvement of Quantification Accuracy in Isobaric Mass Tag-Based Protein Quantification Experiments [J].
Ahrne, Erik ;
Glatter, Timo ;
Vigano, Cristina ;
von Schubert, Conrad ;
Nigg, Erich A. ;
Schmidt, Alexander .
JOURNAL OF PROTEOME RESEARCH, 2016, 15 (08) :2537-2547
[3]   Next-generation proteomics: towards an integrative view of proteome dynamics [J].
Altelaar, A. F. Maarten ;
Munoz, Javier ;
Heck, Albert J. R. .
NATURE REVIEWS GENETICS, 2013, 14 (01) :35-48
[4]   Deep Profiling of Proteome and Phosphoproteome by Isobaric Labeling, Extensive Liquid Chromatography, and Mass Spectrometry [J].
Bai, B. ;
Tan, H. ;
Pagala, V. R. ;
High, A. A. ;
Ichhaporia, V. P. ;
Hendershot, L. ;
Peng, J. .
PROTEOMICS IN BIOLOGY, PT A, 2017, 585 :377-395
[5]   Robust and sensitive iTRAQ quantification on an LTQ orbitrap mass spectrometer [J].
Bantscheff, Marcus ;
Boesche, Markus ;
Eberhard, Dirk ;
Matthieson, Toby ;
Sweetman, Gavain ;
Kuster, Bernhard .
MOLECULAR & CELLULAR PROTEOMICS, 2008, 7 (09) :1702-1713
[6]   Defining the consequences of genetic variation on a proteome-wide scale [J].
Chick, Joel M. ;
Munger, Steven C. ;
Simecek, Petr ;
Huttlin, Edward L. ;
Choi, Kwangbom ;
Gatti, Daniel M. ;
Raghupathy, Narayanan ;
Svenson, Karen L. ;
Churchill, Gary A. ;
Gygi, Steven P. .
NATURE, 2016, 534 (7608) :500-+
[7]   Efficacy of Retinoids in IKZF1-Mutated BCR-ABL1 Acute Lymphoblastic Leukemia [J].
Churchman, Michelle L. ;
Low, Jonathan ;
Qu, Chunxu ;
Paietta, Elisabeth M. ;
Kasper, Lawryn H. ;
Chang, Yunchao ;
Payne-Turner, Debbie ;
Althoff, Mark J. ;
Song, Guangchun ;
Chen, Shann-Ching ;
Ma, Jing ;
Rusch, Michael ;
McGoldrick, Dan ;
Edmonson, Michael ;
Gupta, Pankaj ;
Wang, Yong-Dong ;
Caufield, William ;
Freeman, Burgess ;
Li, Lie ;
Panetta, John C. ;
Baker, Sharyn ;
Yang, Yung-Li ;
Roberts, Kathryn G. ;
McCastlain, Kelly ;
Iacobucci, Ilaria ;
Peters, Jennifer L. ;
Centonze, Victoria E. ;
Notta, Faiyaz ;
Dobson, Stephanie M. ;
Zandi, Sasan ;
Dick, John E. ;
Janke, Laura ;
Peng, Junmin ;
Kodali, Kiran ;
Pagela, Vishwajeeth ;
Min, Jaeki ;
Mayasundari, Anand ;
Williams, Richard T. ;
Willman, Cheryl L. ;
Rowe, Jacob ;
Luger, Selina ;
Dickins, Ross A. ;
Guy, R. Kiplin ;
Chen, Taosheng ;
Mullighan, Charles G. .
CANCER CELL, 2015, 28 (03) :343-356
[8]   Target-decoy search strategy for increased confidence in large-scale protein identifications by mass spectrometry [J].
Elias, Joshua E. ;
Gygi, Steven P. .
NATURE METHODS, 2007, 4 (03) :207-214
[9]   Evaluating Multiplexed Quantitative Phosphopeptide Analysis on a Hybrid Quadrupole Mass Filter/Linear Ion Trap/Orbitrap Mass Spectrometer [J].
Erickson, Brian K. ;
Jedrychowski, Mark P. ;
McAlister, Graeme C. ;
Everley, Robert A. ;
Kunz, Ryan ;
Gygi, Steven P. .
ANALYTICAL CHEMISTRY, 2015, 87 (02) :1241-1249
[10]   High-Resolution Enabled 12-Plex DiLeu Isobaric Tags for Quantitative Proteomics [J].
Frost, Dustin C. ;
Greer, Tyler ;
Li, Lingjun .
ANALYTICAL CHEMISTRY, 2015, 87 (03) :1646-1654