Determination of trace amounts of nickel by differential pulse adsorptive cathodic stripping voltammetry using calconcarboxylic acid as a chelating agent

被引:20
作者
Amini, M. K. [1 ]
Kabiri, M. [1 ]
机构
[1] Univ Isfahan, Dept Chem, Esfahan 8174673441, Iran
关键词
adsorptive cathodic stripping voltammetry; (ACSV); differential pulse voltammetry; nickel; calconcarboxylic acid;
D O I
10.1007/BF03245777
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A method for the determination of nickel(II) by stripping voltammetry is described. The method is based on the adsorptive accumulation of nickel(II) calconcarboxylic acid complex onto a hanging mercury drop electrode (HMDE), followed by the reduction of the adsorbed complex using differential pulse voltammetry. The optimum operating conditions and parameters were found to be 0.05 M NH3/NH4Cl buffer (pH = 9.5) as the supporting electrolyte, a ligand concentration of 1 x 10(-6) M, accumulation potential of -0.5 V (vs. Ag/AgCl) and accumulation time of 60 s. At the optimized conditions, the peak current is proportional to the concentration of nickel in the range of 1.7 x 10(-9) to 4.7 x 10(-7) M (0.1-28 ng ml(-1)) with a detection limit of 0.05 ng ml(-1). The relative standard deviation (n = 10) at nickel concentrations of 2, 10 and 15 ng ml(-1) varies in the range 0.76 to 2.1%. Possible interferences by metal ions, which are of great significance in real matrices, have been studied. The method was successfully applied to the determination of nickel content in a chocolate sample.
引用
收藏
页码:32 / 39
页数:8
相关论文
共 26 条
[1]  
Abollino O, 1999, ELECTROANAL, V11, P870, DOI 10.1002/(SICI)1521-4109(199908)11:12<870::AID-ELAN870>3.3.CO
[2]  
2-C
[3]  
BERMAN E, 1980, TOXIC METALS THEIR A
[4]   Simultaneous determination of several trace metals in seawater using cathodic stripping voltammetry with mixed ligands [J].
Colombo, C ;
van den Berg, CMG .
ANALYTICA CHIMICA ACTA, 1997, 337 (01) :29-40
[5]   DIRECT DETERMINATION OF DISSOLVED COBALT AND NICKEL IN SEAWATER BY DIFFERENTIAL PULSE CATHODIC STRIPPING VOLTAMMETRY PRECEDED BY ADSORPTIVE COLLECTION OF CYCLOHEXANE-1,2-DIONE DIOXIME COMPLEXES [J].
DONAT, JR ;
BRULAND, KW .
ANALYTICAL CHEMISTRY, 1988, 60 (03) :240-244
[6]   Simultaneous determination of trace amounts of cadmium, nickel and cobalt in water samples by adsorptive voltammetry using ammonium 2-amino-cyclopentene dithiocarboxylate as a chelating agent [J].
Ensafi, AA ;
Zarei, K .
TALANTA, 2000, 52 (03) :435-440
[7]   CATHODIC ADSORPTIVE STRIPPING VOLTAMMETRY OF NICKEL COMPLEXED WITH HYDROXYNAPHTHOL BLUE AT A STATIC MERCURY DROP ELECTRODE [J].
FARIAS, PAM ;
OHARA, AK ;
TAKASE, I ;
FERREIRA, SLC ;
GOLD, JS .
TALANTA, 1993, 40 (08) :1167-1171
[8]   On-line preconcentration system for nickel determination in food samples by flame atomic absorption spectrometry [J].
Ferreira, SLC ;
dos Santos, WNL ;
Lemos, VA .
ANALYTICA CHIMICA ACTA, 2001, 445 (02) :145-151
[9]   Nickel determination in saline matrices by ICP-AES after sorption on Amberlite XAD-2 loaded with PAN [J].
Ferreira, SLC ;
de Brito, CF ;
Dantas, AF ;
de Araújo, NML ;
Costa, ACS .
TALANTA, 1999, 48 (05) :1173-1177
[10]   Derivative spectrophotometric determination of nickel using Br-PADAP [J].
Ferreira, SLC ;
Costa, ACS ;
deJesus, DS .
TALANTA, 1996, 43 (10) :1649-1656