Visual performance comparison of 2 extended depth-of-focus intraocular lenses

被引:34
作者
Schojai, Merita [1 ]
Schultz, Tim [1 ]
Jerke, Corinna [1 ]
Boecker, Jorg [1 ]
Dick, H. Burkhard [1 ]
机构
[1] Univ Eye Hosp Bochum, Bochum, Germany
关键词
RANGE; DISSATISFACTION; IMPLANTATION; OUTCOMES;
D O I
10.1097/j.jcrs.0000000000000068
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare the visual acuity and satisfaction outcomes of 2 different concepts of extended depth-of-focus intraocular lenses (EDOF IOLs). Setting: University Eye Hospital Bochum, Germany. Design: Prospective randomized comparative clinical trial. Methods: Patients undergoing cataract surgery with the implantation of 2 different concept EDOF IOLs. In the first group (IC-8 Group), a monofocal 1-piece Tecnis Z B00 IOL (Johnson & Johnson Vision Care, Inc.) was implanted in the dominant eye, and an IC-8 IOL (AcuFocus) was implanted in the nondominant eye. In the second group (Symfony Group), a Tecnis Symfony IOL (Johnson & Johnson Vision Care, Inc.) was implanted in both eyes. The target refraction of the dominant eye was emmetropia and slight myopia (minimonovision, -0.75 diopters) in the nondominant eye. Visual and refractive outcomes and patient satisfaction rates were evaluated 3 months postoperatively. Results: This study comprised 76 eyes of 38 patients. No intraoperative or postoperative complications occurred in either group. Target refraction was reached in both groups without statistically significant differences. The uncorrected distance visual acuity (UDVA, photopic and mesopic light conditions) was excellent in both groups with statistically significantly better results in the IC-8 goup (logarithm of the minimum angle of resolution; IC-8 Group (0.1 +/- 0.07 logarithm of the minimum angle of resolution [logMAR]; Symfony Group 0.07 +/- 0.1 logMAR, P value .02 [photopic]; IC-8 group 0.12 +/- 0.09 logMAR, Symfony group 0.22 +/- 0.1 logMAR, P value < .01 [ mesopic]). Binocular uncorrected intermediate visual acuity (UIVA) and uncorrected near visual acuity (UNVA) were also good in both groups without statistically significant differences (UIVA: IC-8 Group, 0.01 +/- 0.07 logMAR, Symfony Group 0.01 +/- 0.08 logMAR, P value .35; UNVA: IC-8 Group 0.14 +/- 0.11, Symfony Group 0.09 +/- 0.08, P value .14). Subjective satisfaction was high in both groups. Conclusions: Both EDOF IOLs provided a very good UDVA with superior results in the IC-8 Group, and a good UIVA and UNVA under photopic light conditions. Subjective patient satisfaction was higher in the IC-8 Group. Copyright (C) 2020 Published by Wolters Kluwer on behalf of ASCRS and ESCRS
引用
收藏
页码:388 / 393
页数:6
相关论文
共 13 条
[1]   Multifocal intraocular lenses: Relative indications and contraindications for implantation [J].
Braga-Mele, Rosa ;
Chang, David ;
Dewey, Steven ;
Foster, Gary ;
Henderson, Bonnie An ;
Hill, Warren ;
Hoffman, Richard ;
Little, Brian ;
Mamalis, Nick ;
Oetting, Thomas ;
Serafano, Donald ;
Talley-Rostov, Audrey ;
Vasavada, Abhay ;
Yoo, Sonia .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (02) :313-322
[2]   Developments in the correction of presbyopia II: surgical approaches [J].
Charman, W. Neil .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2014, 34 (04) :397-426
[3]   THE LENS OPACITIES CLASSIFICATION SYSTEM-III [J].
CHYLACK, LT ;
WOLFE, JK ;
SINGER, DM ;
LESKE, MC ;
BULLIMORE, MA ;
BAILEY, IL ;
FRIEND, J ;
MCCARTHY, D ;
WU, SY .
ARCHIVES OF OPHTHALMOLOGY, 1993, 111 (06) :831-836
[4]   Influence of the level of monovision on visual outcome with an extended range of vision intraocular lens [J].
Cochener, Beatrice .
CLINICAL OPHTHALMOLOGY, 2018, 12 :2305-2312
[5]   Clinical outcomes of a new extended range of vision intraocular lens: International Multicenter Concerto Study [J].
Cochener, Beatrice .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (09) :1268-1275
[6]   Dissatisfaction after implantation of multifocal intraocular lenses [J].
de Vries, Niels E. ;
Webers, Carroll A. B. ;
Touwslager, Wouter R. H. ;
Bauer, Noel J. C. ;
de Brabander, John ;
Berendschot, Tos T. ;
Nuijts, Rudy M. M. A. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (05) :859-865
[7]   Binocular and Monocular Implantation of Small-Aperture Intraocular Lenses in Cataract Surgery [J].
Dick, H. Burkhard ;
Elling, Matthias ;
Schultz, Tim .
JOURNAL OF REFRACTIVE SURGERY, 2018, 34 (09) :629-+
[8]   Prospective multicenter trial of a small-aperture intraocular lens in cataract surgery [J].
Dick, H. Burkhard ;
Piovella, Matteo ;
Vukich, John ;
Vilupuru, Srividhya ;
Lin, Ling .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2017, 43 (07) :956-968
[9]   Subjective photic phenomena with refractive multifocal and monofocal intraocular lenses -: Results of a multicenter questionnaire [J].
Häring, G ;
Dick, HB ;
Krummenauer, F ;
Weissmantel, U ;
Kröncke, W .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (02) :245-249
[10]   Comparative analysis of visual outcomes with 4 intraocular lenses: Monofocal, multifocal, and extended range of vision [J].
Pedrotti, Emilio ;
Carones, Francesco ;
Aiello, Francesco ;
Mastropasqua, Rodolfo ;
Bruni, Enrico ;
Bonacci, Erika ;
Talli, Pietro ;
Nucci, Carlo ;
Mariotti, Cesare ;
Marchini, Giorgio .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2018, 44 (02) :156-167