Wireless Tissue Palpation for Intraoperative Detection of Lumps in the Soft Tissue

被引:60
作者
Beccani, Marco [1 ]
Di Natali, Christian [1 ]
Sliker, Levin J. [2 ]
Schoen, Jonathan A. [3 ]
Rentschler, Mark E. [2 ]
Valdastri, Pietro [1 ]
机构
[1] Vanderbilt Univ, Dept Mech Engn, Sci & Technol Robot Med Lab, Nashville, TN 37235 USA
[2] Univ Colorado, Dept Mech Engn, Boulder, CO 80309 USA
[3] Univ Colorado Hosp, Dept Surg, Aurora, CO 80045 USA
基金
美国国家科学基金会;
关键词
Force feedback; minimally invasive surgery (MIS); soft tissue identification; surgical robotics; tissue palpation; tumor localization; LAPAROSCOPIC ULTRASONOGRAPHY; ULTRASOUND PROBE; TACTILE SENSOR; FORCE SENSOR; SURGERY; SYSTEM; IDENTIFICATION; INTEGRATION; FEEDBACK;
D O I
10.1109/TBME.2013.2279337
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In an open surgery, identification of precise margins for curative tissue resection is performed bymanual palpation. This is not the case for minimally invasive and robotic procedures, where tactile feedback is either distorted or not available. In this paper, we introduce the concept of intraoperative wireless tissue palpation. The wireless palpation probe (WPP) is a cylindrical device (15 mm in diameter, 60 mm in length) that can be deployed through a trocar incision and directly controlled by the surgeon to create a volumetric stiffness distribution map of the region of interest. This map can then be used to guide the tissue resection to minimize healthy tissue loss. The wireless operation prevents the need for a dedicated port and reduces the chance of instrument clashing in the operating field. The WPP is able to measure in real time the indentation pressure with a sensitivity of 34 Pa, the indentation depth with an accuracy of 0.68 mm, and the probe position with a maximum error of 11.3 mm in a tridimensional workspace. The WPP was assessed on the benchtop in detecting the local stiffness of two different silicone tissue simulators (elastic modulus ranging from 45 to 220 kPa), showing a maximum relative error below 5%. Then, in vivo trials were aimed to identify an agar-gel lump injected into a porcine liver and to assess the device usability within the frame of a laparoscopic procedure. The stiffness map created intraoperatively by the WPP was compared with a map generated ex vivo by a standard uniaxial material tester, showing less than 8% local stiffness error at the site of the lump.
引用
收藏
页码:353 / 361
页数:9
相关论文
共 34 条
[1]  
Baki P., 2012, SENSOR ACTUAT A-PHYS, V192, P101
[2]  
Beccani M, 2013, IEEE INT CONF ROBOT, P711, DOI 10.1109/ICRA.2013.6630651
[3]   Maximizing coupling strength of magnetically anchored surgical instruments: how thick can we go? [J].
Best, Sara L. ;
Bergs, Richard ;
Gedeon, Makram ;
Paramo, Juan ;
Fernandez, Raul ;
Cadeddu, Jeffrey A. ;
Scott, Daniel J. .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2011, 25 (01) :153-159
[4]   AN ADVANCED ROBOT SYSTEM FOR AUTOMATED DIAGNOSTIC TASKS THROUGH PALPATION [J].
DARIO, P ;
BERGAMASCO, M .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1988, 35 (02) :118-126
[5]   Real-Time Pose Detection for Magnetic Medical Devices [J].
Di Natali, Christian ;
Beccani, Marco ;
Valdastri, Pietro .
IEEE TRANSACTIONS ON MAGNETICS, 2013, 49 (07) :3524-3527
[6]  
Fratt L., 2012, HLTH IMAG, V10, P12
[7]  
Fuller J., 2003, LAPAROSCOPIC TROCAR
[8]   Algorithms for autonomous exploration and estimation in compliant environments [J].
Goldman, R. E. ;
Bajo, A. ;
Simaan, N. .
ROBOTICA, 2013, 31 :71-87
[9]  
Gwilliam James C., 2010, 2010 IEEE Haptics Symposium (Formerly known as Symposium on Haptic Interfaces for Virtual Environment and Teleoperator Systems), P21, DOI 10.1109/HAPTIC.2010.5444685
[10]   Image-guided robotic surgery: update on research and potential applications in urologic surgery [J].
Herrell, S. Duke ;
Galloway, Robert L. ;
Su, Li-Ming .
CURRENT OPINION IN UROLOGY, 2012, 22 (01) :47-54