Evaluation of genetic models for COD and TSS estimation in wastewater through its spectrophotometric response

被引:5
作者
Carreres-Prieto, Daniel [1 ]
Ybarra-Moreno, Javier [2 ]
Garcia, Juan T. [1 ]
Cerdan-Cartagena, Fernando [3 ]
机构
[1] Univ Politecn Cartagena, Dept Min & Civil Engn, Cartagena 30202, Spain
[2] Edam Ltda, Santiago, Chile
[3] Univ Politecn Cartagena, Dept Informat & Commun Technol, Cartagena 30202, Spain
关键词
COD; genetic algorithm; LED spectrophotometer; TSS; wastewater pollutant characterization; TOTAL PROTEIN; ALGORITHMS; OPTIMIZATION; QUALITY; DESIGN; FAT;
D O I
10.2166/wst.2022.138
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In an urban wastewater treatment plant (WWTP), early knowledge of the pollutant load levels throughout the plant is key to optimize its processes and achieve better purification levels. Molecular spectrophotometry has begun to gain prominence in this wastewater characterization process, as it is a simple, fast, inexpensive and non-invasive technique. In this research work, different mathematical models based on genetic algorithms have been developed for the estimation of COD and TSS from the spectral response of the samples, measured in the 380-700 nm range by means of an LED spectrophotometer developed by the researchers. A field campaign was carried out in Mapocho-Trebal WWTP (Chile), where 550 samples were obtained in three different parts of the plant: at the inlet (raw wastewater), at the outlet (secondary treated wastewater) and at the outlet of the primary clarifier. A total of 18 estimation models have been calculated by mean of HeuristicLab software, which have presented a high accuracy, with a Pearson's coefficient between 80 and 90% in most cases. In order to achieve the most accurate models possible to characterize each part of the plant, specific models have also been developed, as well as combined models that are valid for all types of wastewater.
引用
收藏
页码:2565 / 2580
页数:16
相关论文
共 34 条
[1]   Offspring selection: A new self-adaptive selection scheme for genetic algorithms [J].
Affenzeller, M ;
Wagner, S .
ADAPTIVE AND NATURAL COMPUTING ALGORITHMS, 2005, :218-221
[2]  
Benesty J., 2009, SPR TOP SIG PROC, P1
[3]  
Beraud B, 2009, STUD COMPUT INTELL, V218, P163
[4]   Scatter-based quantitative spectroscopic analysis of milk fat and total protein in the region 400-1100 nm in the presence of fat globule size variability [J].
Bogomolov, A. ;
Melenteva, A. .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2013, 126 :129-139
[5]   Quantitative determination of fat and total protein in milk based on visible light scatter [J].
Bogomolov, Andrey ;
Dietrich, Stefan ;
Boldrini, Barbara ;
Kessler, Rudolf W. .
FOOD CHEMISTRY, 2012, 134 (01) :412-418
[6]   Estimation of water quality by UV/Vis spectrometry in the framework of treated wastewater reuse [J].
Carre, Erwan ;
Perot, Jean ;
Jauzein, Vincent ;
Lin, Liming ;
Lopez-Ferber, Miguel .
WATER SCIENCE AND TECHNOLOGY, 2017, 76 (03) :633-641
[7]   Wastewater Quality Estimation through Spectrophotometry-Based Statistical Models [J].
Carreres-Prieto, Daniel ;
Garcia, Juan T. ;
Cerdan-Cartagena, Fernando ;
Suardiaz-Muro, Juan .
SENSORS, 2020, 20 (19) :1-29
[8]   Spectroscopy Transmittance by LED Calibration [J].
Carreres-Prieto, Daniel ;
Garcia, Juan T. ;
Cerdan-Cartagena, Fernando ;
Suardiaz-Muro, Juan .
SENSORS, 2019, 19 (13)
[9]   Development of variable pathlength UV-vis spectroscopy combined with partial-least-squares regression for wastewater chemical oxygen demand (COD) monitoring [J].
Chen, Baisheng ;
Wu, Huanan ;
Li, Sam Fong Yau .
TALANTA, 2014, 120 :325-330
[10]  