Measurement of coronary artery calcium volume using ultra-high-resolution computed tomography: A preliminary phantom and cadaver study

被引:11
作者
Fukumoto, Wataru [1 ]
Nagaoka, Mami [2 ,5 ]
Higaki, Toru [1 ,4 ]
Tatsugami, Fuminari [1 ,4 ]
Nakamura, Yuko [1 ,4 ]
Oostveen, Luuk [3 ,6 ]
Klein, Willemijn [3 ,6 ]
Prokop, Mathias [3 ,6 ]
Awai, Kazuo [1 ,4 ]
机构
[1] Hiroshima Univ, Inst Biomed Hlth Sci, Dept Diagnost Radiol, Hiroshima, Japan
[2] Hiroshima Univ, Sch Med, Hiroshima, Japan
[3] Radboud Univ Nijmegen, Dept Radiol & Nucl Med, Med Ctr, Nijmegen, Netherlands
[4] Hiroshima Univ, Inst Biomed Hlth Sci, Dept Diagnost Radiol, Minami Ku, 1-2-3 Kasumi, Hiroshima 7348551, Japan
[5] Hiroshima Univ, Sch Med, Minami Ku, 1-2-3 Kasumi, Hiroshima 7348551, Japan
[6] Radboud Univ Nijmegen, Radboud Univ Med Ctr, Dept Radiol & Nucl Med, Houtlaan 4, NL-6525 XZ Nijmegen, Netherlands
关键词
Coronary artery calcium scores; Ultra-high-resolution CT; Cadaver; PROGNOSTIC VALUE; CT ANGIOGRAPHY; CALCIFICATION; DISEASE; RECONSTRUCTION; ATHEROSCLEROSIS; REPRODUCIBILITY; ABSENCE; EVENTS;
D O I
10.1016/j.ejro.2020.100253
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: In this phantom- and cadaver study we investigated the differences of coronary artery calcium (CAC) volume on ultra-high-resolution computed tomography (U-HRCT) scans and conventional CT. Methods: We scanned a coronary calcium phantom and the coronary arteries of five cadavers using U-HRCT in normal- and super-high resolution (NR, SHR) mode. The NR mode was similar to conventional CT; 896 detector channels, a matrix size of 512, and a slice thickness of 0.5 mm were applied. In SHR mode, we used 1792 detector channels, a matrix size of 1024, and a slice thickness of 0.25 mm. The CAC volume on NR- and SHR images were recorded. Differences in the physical- and the calculated CAC volume were defined as the error value and compared between NR- and SHR images of the phantom. Differences between the CAC volume on NR- and SHR scans of the cadavers were also recorded. Results: The mean error value was lower on SHR- than NR images of the phantom (14.0 %, SD 11.1 vs 20.1 %, SD 15.2, p = 0.01). The mean CAC volume was significantly higher on SHR- than NR images of the cadavers (153.4 mm(3), SD 161.0 vs 144.7 mm(3), SD 164.8, p < 0.01). Conclusions: As small calcifications were more clearly visualized on U-HRCT images in SHR mode than on conventional (NR) CT scans, SHR imaging may facilitate the accurate quantification of the CAC.
引用
收藏
页数:6
相关论文
共 31 条
[21]   Quantitative measurement of airway dimensions using ultra-high resolution computed tomography [J].
Tanabe, Naoya ;
Oguma, Tsuyoshi ;
Sato, Susumu ;
Kubo, Takeshi ;
Kozawa, Satoshi ;
Shima, Hiroshi ;
Koizumi, Koji ;
Sato, Atsuyasu ;
Muro, Shigeo ;
Togashi, Kaori ;
Hirai, Toyohiro .
RESPIRATORY INVESTIGATION, 2018, 56 (06) :489-496
[22]   Deep learning-based image restoration algorithm for coronary CT angiography [J].
Tatsugami, Fuminari ;
Higaki, Toru ;
Nakamura, Yuko ;
Yu, Zhou ;
Zhou, Jian ;
Lu, Yujie ;
Fujioka, Chikako ;
Kitagawa, Toshiro ;
Kihara, Yasuki ;
Iida, Makoto ;
Awai, Kazuo .
EUROPEAN RADIOLOGY, 2019, 29 (10) :5322-5329
[23]   Coronary Artery Stent Evalurtion with Modell-based lteratilve Reconstruction Coronary CT Angiography [J].
Tatsugami, Fuminari ;
Higaki, Toru ;
Sakane, Hiroaki ;
Fukumoto, Wataru ;
Kaichi, Yoko ;
Iida, Makoto ;
Baba, Yasutaka ;
Kiguchi, Masao ;
Kihara, Yasuki ;
Tsushima, So ;
Awai, Kazuo .
ACADEMIC RADIOLOGY, 2017, 24 (08) :975-981
[24]   Coronary artery calcium scoring with multislice computed tomography -: In vitro assessment of a low tube voltage protocol [J].
Thomas, Christoph K. ;
Muehlenbruch, Georg ;
Wildberger, Joachim E. ;
Hohl, Christian ;
Das, Marco ;
Guenther, Rolf W. ;
Mahnken, Andreas H. .
INVESTIGATIVE RADIOLOGY, 2006, 41 (09) :668-673
[25]   Accuracy in Quantification of Coronary Calcification with CT: A Cork-Dog Heart Phantom Study [J].
Tseng, Philip H. ;
Mao, Songshou ;
Chow, David Z. ;
Gao, Yanlin ;
Chang, William W. ;
Schiff, Michael M. ;
Kim, Katherine Y. ;
Kwan, Jessica Y. ;
Budoff, Matthew J. .
ACADEMIC RADIOLOGY, 2010, 17 (10) :1249-1253
[26]   Identifying Small Coronary Calcification in Non-Contrast 0.5-mm Slice Reconstruction to Diagnose Coronary Artery Disease in Patients with a Conventional Zero Coronary Artery Calcium Score [J].
Urabe, Yoji ;
Yamamoto, Hideya ;
Kitagawa, Toshiro ;
Utsunomiya, Hiroto ;
Tsushima, Hiroshi ;
Tatsugami, Fuminari ;
Awai, Kazuo ;
Kihara, Yasuki .
JOURNAL OF ATHEROSCLEROSIS AND THROMBOSIS, 2016, 23 (12) :1324-1333
[27]   Assessment of coronary artery calcium by using volumetric 320-row multi-detector computed tomography: comparison of 0.5 mm with 3.0 mm slice reconstructions [J].
van der Bijl, Noortje ;
de Bruin, Paul W. ;
Geleijns, Jacob ;
Bax, Jeroen J. ;
Schuijf, Joanne D. ;
de Roos, Albert ;
Kroft, Lucia J. M. .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2010, 26 (04) :473-482
[28]   Coronary Calcium Score as a Predictor for Coronary Artery Disease and Cardiac Events in Japanese High-Risk Patients [J].
Yamamoto, Hideya ;
Ohashi, Norihiko ;
Ishibashi, Ken ;
Utsunomiya, Hiroto ;
Kunita, Eiji ;
Oka, Toshiharu ;
Horiguchi, Jun ;
Kihara, Yasuki .
CIRCULATION JOURNAL, 2011, 75 (10) :2424-2431
[29]   Ultrahigh-resolution CT scan of the temporal bone [J].
Yamashita, Koji ;
Hiwatashi, Akio ;
Togao, Osamu ;
Kikuchi, Kazufumi ;
Matsumoto, Nozomu ;
Momosaka, Daichi ;
Nakatake, Hiroshi ;
Sakai, Yuki ;
Honda, Hiroshi .
EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2018, 275 (11) :2797-2803
[30]   Subjective and objective comparisons of image quality between ultra-high-resolution CT and conventional area detector CT in phantoms and cadaveric human lungs [J].
Yanagawa, Masahiro ;
Hata, Akinori ;
Honda, Osamu ;
Kikuchi, Noriko ;
Miyata, Tomo ;
Uranishi, Ayumi ;
Tsukagoshi, Shinsuke ;
Tomiyama, Noriyuki .
EUROPEAN RADIOLOGY, 2018, 28 (12) :5060-5068