Measurement of coronary artery calcium volume using ultra-high-resolution computed tomography: A preliminary phantom and cadaver study

被引:11
作者
Fukumoto, Wataru [1 ]
Nagaoka, Mami [2 ,5 ]
Higaki, Toru [1 ,4 ]
Tatsugami, Fuminari [1 ,4 ]
Nakamura, Yuko [1 ,4 ]
Oostveen, Luuk [3 ,6 ]
Klein, Willemijn [3 ,6 ]
Prokop, Mathias [3 ,6 ]
Awai, Kazuo [1 ,4 ]
机构
[1] Hiroshima Univ, Inst Biomed Hlth Sci, Dept Diagnost Radiol, Hiroshima, Japan
[2] Hiroshima Univ, Sch Med, Hiroshima, Japan
[3] Radboud Univ Nijmegen, Dept Radiol & Nucl Med, Med Ctr, Nijmegen, Netherlands
[4] Hiroshima Univ, Inst Biomed Hlth Sci, Dept Diagnost Radiol, Minami Ku, 1-2-3 Kasumi, Hiroshima 7348551, Japan
[5] Hiroshima Univ, Sch Med, Minami Ku, 1-2-3 Kasumi, Hiroshima 7348551, Japan
[6] Radboud Univ Nijmegen, Radboud Univ Med Ctr, Dept Radiol & Nucl Med, Houtlaan 4, NL-6525 XZ Nijmegen, Netherlands
关键词
Coronary artery calcium scores; Ultra-high-resolution CT; Cadaver; PROGNOSTIC VALUE; CT ANGIOGRAPHY; CALCIFICATION; DISEASE; RECONSTRUCTION; ATHEROSCLEROSIS; REPRODUCIBILITY; ABSENCE; EVENTS;
D O I
10.1016/j.ejro.2020.100253
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: In this phantom- and cadaver study we investigated the differences of coronary artery calcium (CAC) volume on ultra-high-resolution computed tomography (U-HRCT) scans and conventional CT. Methods: We scanned a coronary calcium phantom and the coronary arteries of five cadavers using U-HRCT in normal- and super-high resolution (NR, SHR) mode. The NR mode was similar to conventional CT; 896 detector channels, a matrix size of 512, and a slice thickness of 0.5 mm were applied. In SHR mode, we used 1792 detector channels, a matrix size of 1024, and a slice thickness of 0.25 mm. The CAC volume on NR- and SHR images were recorded. Differences in the physical- and the calculated CAC volume were defined as the error value and compared between NR- and SHR images of the phantom. Differences between the CAC volume on NR- and SHR scans of the cadavers were also recorded. Results: The mean error value was lower on SHR- than NR images of the phantom (14.0 %, SD 11.1 vs 20.1 %, SD 15.2, p = 0.01). The mean CAC volume was significantly higher on SHR- than NR images of the cadavers (153.4 mm(3), SD 161.0 vs 144.7 mm(3), SD 164.8, p < 0.01). Conclusions: As small calcifications were more clearly visualized on U-HRCT images in SHR mode than on conventional (NR) CT scans, SHR imaging may facilitate the accurate quantification of the CAC.
引用
收藏
页数:6
相关论文
共 31 条
[1]  
Achenbach S, 2000, CIRCULATION, V102, P2823
[2]  
Akagi M., 2019, EUR RADIOL, DOI [10.1007/s00330-019-06170-06173, DOI 10.1007/S00330-019-06170-06173]
[3]   Scoring of coronary artery calcium scans: History, assumptions, current limitations, and future directions [J].
Alluri, Krishna ;
Joshi, Parag H. ;
Henry, Travis S. ;
Blumenthal, Roger S. ;
Nasir, Khurram ;
Blaha, Michael J. .
ATHEROSCLEROSIS, 2015, 239 (01) :109-117
[4]   Cardiovascular events with absent or minimal coronary calcification: The Multi-Ethnic Study of Atherosclerosis (MESA) [J].
Budoff, Matthew J. ;
McClelland, Robyn L. ;
Nasir, Khurram ;
Greenland, Philip ;
Kronmal, Richard A. ;
Kondos, George T. ;
Shea, Steven ;
Lima, Joao A. C. ;
Blumenthal, Roger S. .
AMERICAN HEART JOURNAL, 2009, 158 (04) :554-561
[5]   Coronary artery disease: Improved reproducibility of calcium scoring with an electron-beam CT volumetric method [J].
Callister, TQ ;
Cooil, B ;
Raya, SP ;
Lippolis, NJ ;
Russo, DJ ;
Raggi, P .
RADIOLOGY, 1998, 208 (03) :807-814
[6]   Interest of HYPR flow dynamic MRA for characterization of cerebral arteriovenous malformations: comparison with TRICKS MRA and catheter DSA [J].
Dautry, Raphael ;
Edjlali, Myriam ;
Roca, Pauline ;
Rabrait, Cecile ;
Wu, Yijing ;
Johnson, Kevin ;
Wieben, Olivier ;
Trystram, Denis ;
Rodriguez-Regent, Christine ;
Alshareef, Fawaz ;
Turski, Patrick ;
Meder, Jean-Francois ;
Naggara, Olivier ;
Oppenheim, Catherine .
EUROPEAN RADIOLOGY, 2015, 25 (11) :3230-3237
[7]   Improvement of cardiovascular risk prediction using coronary imaging: subclinical atherosclerosis: the memory of lifetime risk factor exposure [J].
Erbel, Raimund ;
Budoff, Matthew .
EUROPEAN HEART JOURNAL, 2012, 33 (10) :1201-+
[8]   The Absence of Coronary Calcification Does Not Exclude Obstructive Coronary Artery Disease or the Need for Revascularization in Patients Referred for Conventional Coronary Angiography [J].
Gottlieb, Ilan ;
Miller, Julie M. ;
Arbab-Zadeh, Armin ;
Dewey, Marc ;
Clouse, Melvin E. ;
Sara, Leonardo ;
Niinuma, Hiroyuki ;
Bush, David E. ;
Paul, Narinder ;
Vavere, Andrea L. ;
Texter, John ;
Brinker, Jeffery ;
Lima, Joao A. C. ;
Rochitte, Carlos E. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (07) :627-634
[9]   Effect of Matrix Size on the Image Quality of Ultra-high-resolution CT of the Lung: Comparison of 512 x 512, 1024 x 1024, and 2048 x 2048 [J].
Hata, Akinori ;
Yanagawa, Masahiro ;
Honda, Osamu ;
Kikuchi, Noriko ;
Miyata, Tomo ;
Tsukagoshi, Shinsuke ;
Uranishi, Ayumi ;
Tomiyama, Noriyuki .
ACADEMIC RADIOLOGY, 2018, 25 (07) :869-876
[10]   Influence of gantry rotation time and scan mode on image quality in ultrahigh-resolution CT system [J].
Honda, Osamu ;
Yanagawa, Masahiro ;
Hata, Akinori ;
Kikuchi, Noriko ;
Miyata, Tomo ;
Tsukagoshi, Shinsuke ;
Uranishi, Ayumi ;
Tomiyama, Noriyuki .
EUROPEAN JOURNAL OF RADIOLOGY, 2018, 103 :71-75