Xenon-enhanced computed tomography quantifies normal maxillary sinus ventilation

被引:17
作者
Leopold, D [1 ]
Zinreich, SJ
Simon, BA
Cullen, MM
Marcucci, C
机构
[1] Univ Nebraska, Nebraska Med Ctr 981225, Dept Otolaryngol Head & Neck Surg, Omaha, NE 68182 USA
[2] Johns Hopkins Univ, Dept Radiol, Baltimore, MD USA
[3] Johns Hopkins Univ, Dept Anesthesiol, Baltimore, MD USA
[4] Johns Hopkins Univ, Dept Otolaryngol Head & Neck Surg, Baltimore, MD USA
[5] Johns Hopkins Med Inst, Baltimore, MD 21205 USA
关键词
D O I
10.1016/S0194-5998(00)70059-3
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
OBJECTIVE: The purpose of this study was to determine the applicability, safety, and normal parameters of a xenon-enhanced CT technique to quantify maxillary sinus ventilation. PATIENTS AND METHODS: Nine healthy subjects inhaled a xenon-oxygen-air mixture through their noses while repeated CT scans were performed through the same section of their sinuses. Images were obtained every 1 to 3 minutes and analyzed to measure the density of the gas in the maxillary sinus as a function of time. RESULTS: individual nasal cavity time constants ranged from 0.5 to 18 minutes. Studies performed after decongestion showed poorer sinus ventilation. CONCLUSIONS: The xenon-CT washin/washout technique is safe, effective, and gives representative data.
引用
收藏
页码:422 / 424
页数:3
相关论文
共 7 条