Development of Ultrafast Separations Using Negative Pulse Partial Modulation To Enable New Directions in Gas Chromatography

被引:22
作者
Gough, Derrick V. [1 ]
Song, Dong H. [1 ]
Schoneich, Sonia [1 ]
Prebihalo, Sarah E. [1 ]
Synovec, Robert E. [1 ]
机构
[1] Univ Washington, Dept Chem, Box 351700, Seattle, WA 98195 USA
关键词
MASS-SPECTROMETRIC DETECTION; HIGH PEAK-CAPACITY; STATISTICAL-THEORY; VALVE; INJECTION; OVERLAP; RATIO;
D O I
10.1021/acs.analchem.9b01085
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Partial modulation via a pulse flow valve operated in the negative pulse mode is developed for high-speed one-dimensional gas chromatography (1D-GC), comprehensive two-dimensional (2D) gas chromatography (GC x GC), and comprehensive three-dimensional gas chromatography (GC(3)). The pulse flow valve readily provides very short modulation periods, P-M, demonstrated herein at 100, 200, and 300 ms, and holds significant promise to increase the scope and applicability of GC instrumentation. The negative pulse mode creates an extremely narrow, local analyte concentration pulse. The reproducibility of the negative pulse mode is validated in a 1D-GC mode, where a pseudosteady-state analyte stream is modulated, and 8 analytes are baseline resolved (resolution, R-s >= 1.5) in a 200 ms window, providing a peak capacity, n(c), of 14 at unit resolution (R-s = 1.0). Additionally, the pulse width, p(w), of the pulse flow valve "injection" relationship to peak width-at-base, w(b), resolution between peaks and detection sensitivity are studied. To demonstrate the applicability to GC x GC, a high-speed separation of a 20-component test mixture of similar, volatile analytes is shown. Analytes were separated on the second-dimension column, D-2, with (2)w(b) ranging from 7 to 12 ms, providing an exceptional D-2 peak capacity, (2)n(c), of similar to 12 using a modulation period (P-M) of 100 ms. Next, a 12 min separation of a diesel sample using a P-M of 300 ms is presented. The (1)w(b) is similar to 4 s, resulting in a (1)n(c), of similar to 180, and (2)w(b) is similar to 18 ms, resulting in a (2)n(c) of similar to 17, thus achieving a n(c,2D) of similar to 3000 in this rapid GC x GC diesel separation. Finally, GC(3) with time-of-flight mass spectrometry (TOFMS) detection using a P-M of 100 ms applied between the D-2 and D-3 columns is reported. Narrow third dimension, D-3, peaks with (3)w(b) of similar to 15 ms were obtained, resulting in a GC(3) peak capacity, n(c,3D), of similar to 35 000 in a 45 min separation.
引用
收藏
页码:7328 / 7335
页数:8
相关论文
共 40 条
  • [21] Evaluation of conditions of comprehensive two-dimensional gas chromatography that yield a near-theoretical maximum in peak capacity gain
    Klee, Matthew S.
    Cochran, Jack
    Merrick, Mark
    Blumberg, Leonid M.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2015, 1383 : 151 - 159
  • [22] CRYOFOCUSING INLET WITH REVERSE FLOW SAMPLE COLLECTION FOR GAS-CHROMATOGRAPHY
    KLEMP, MA
    AKARD, ML
    SACKS, RD
    [J]. ANALYTICAL CHEMISTRY, 1993, 65 (18) : 2516 - 2521
  • [23] COMPREHENSIVE 2-DIMENSIONAL GAS-CHROMATOGRAPHY USING AN ON-COLUMN THERMAL MODULATOR INTERFACE
    LIU, ZY
    PHILLIPS, JB
    [J]. JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1991, 29 (06) : 227 - 231
  • [24] Multidimensional gas chromatography using microfluidic switching and low thermal mass gas chromatography for the characterization of targeted volatile organic compounds
    Luong, J.
    Gras, R.
    Hawryluk, M.
    Shellie, R. A.
    Cortes, H. J.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2013, 1288 : 105 - 110
  • [25] Multidimensional gas chromatography
    Marriott, Philip J.
    Chin, Sung-Tong
    Maikhunthod, Bussayarat
    Schmarr, Hans-Georg
    Bieri, Stefan
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2012, 34 : 1 - 21
  • [26] Fingerprinting polychlorinated biphenyls in environmental samples using comprehensive two-dimensional gas chromatography with time-of-flight mass spectrometry
    Megson, David
    Kalin, Robert
    Worsfold, Paul J.
    Gauchotte-Lindsay, Caroline
    Patterson, Donald G., Jr.
    Lohan, Maeve C.
    Comber, Sean
    Brown, Thomas A.
    O'Sullivan, Gwen
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2013, 1318 : 276 - 283
  • [27] Review of chemometric analysis techniques for comprehensive two dimensional separations data
    Pierce, Karisa M.
    Kehimkar, Benjamin
    Marney, Luke C.
    Hoggard, Jamin C.
    Synovec, Robert E.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2012, 1255 : 3 - 11
  • [28] Method to determine the true modulation ratio for comprehensive two-dimensional gas chromatography
    Pinkerton, David K.
    Parsons, Brendon A.
    Synovec, Robert E.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2016, 1476 : 114 - 123
  • [29] Multidimensional Gas Chromatography: Advances in Instrumentation, Chemometrics, and Applications
    Prebihalo, Sarah E.
    Berrier, Kelsey L.
    Freye, Chris E.
    Bahaghighat, H. Daniel
    Moore, Nicholas R.
    Pinkerton, David K.
    Synovec, Robert E.
    [J]. ANALYTICAL CHEMISTRY, 2018, 90 (01) : 505 - 532
  • [30] Investigation of high-speed gas chromatography using synchronized dual-valve injection and resistively heated temperature programming
    Reid, Vanessa R.
    McBrady, Adam D.
    Synovec, Robert E.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2007, 1148 (02) : 236 - 243