Development of Ultrafast Separations Using Negative Pulse Partial Modulation To Enable New Directions in Gas Chromatography

被引:22
作者
Gough, Derrick V. [1 ]
Song, Dong H. [1 ]
Schoneich, Sonia [1 ]
Prebihalo, Sarah E. [1 ]
Synovec, Robert E. [1 ]
机构
[1] Univ Washington, Dept Chem, Box 351700, Seattle, WA 98195 USA
关键词
MASS-SPECTROMETRIC DETECTION; HIGH PEAK-CAPACITY; STATISTICAL-THEORY; VALVE; INJECTION; OVERLAP; RATIO;
D O I
10.1021/acs.analchem.9b01085
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Partial modulation via a pulse flow valve operated in the negative pulse mode is developed for high-speed one-dimensional gas chromatography (1D-GC), comprehensive two-dimensional (2D) gas chromatography (GC x GC), and comprehensive three-dimensional gas chromatography (GC(3)). The pulse flow valve readily provides very short modulation periods, P-M, demonstrated herein at 100, 200, and 300 ms, and holds significant promise to increase the scope and applicability of GC instrumentation. The negative pulse mode creates an extremely narrow, local analyte concentration pulse. The reproducibility of the negative pulse mode is validated in a 1D-GC mode, where a pseudosteady-state analyte stream is modulated, and 8 analytes are baseline resolved (resolution, R-s >= 1.5) in a 200 ms window, providing a peak capacity, n(c), of 14 at unit resolution (R-s = 1.0). Additionally, the pulse width, p(w), of the pulse flow valve "injection" relationship to peak width-at-base, w(b), resolution between peaks and detection sensitivity are studied. To demonstrate the applicability to GC x GC, a high-speed separation of a 20-component test mixture of similar, volatile analytes is shown. Analytes were separated on the second-dimension column, D-2, with (2)w(b) ranging from 7 to 12 ms, providing an exceptional D-2 peak capacity, (2)n(c), of similar to 12 using a modulation period (P-M) of 100 ms. Next, a 12 min separation of a diesel sample using a P-M of 300 ms is presented. The (1)w(b) is similar to 4 s, resulting in a (1)n(c), of similar to 180, and (2)w(b) is similar to 18 ms, resulting in a (2)n(c) of similar to 17, thus achieving a n(c,2D) of similar to 3000 in this rapid GC x GC diesel separation. Finally, GC(3) with time-of-flight mass spectrometry (TOFMS) detection using a P-M of 100 ms applied between the D-2 and D-3 columns is reported. Narrow third dimension, D-3, peaks with (3)w(b) of similar to 15 ms were obtained, resulting in a GC(3) peak capacity, n(c,3D), of similar to 35 000 in a 45 min separation.
引用
收藏
页码:7328 / 7335
页数:8
相关论文
共 40 条
  • [1] Comprehensive two-dimensional gas chromatography and time-of-flight mass spectrometry detection with a 50 ms modulation period
    Bahaghighat, H. Daniel
    Freye, Chris E.
    Gough, Derrick, V
    Synovec, Robert E.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2019, 1583 : 117 - 123
  • [2] Recent advances in modulator technology for comprehensive two dimensional gas chromatography
    Bahaghighat, H. Daniel
    Freye, Chris E.
    Synovec, Robert E.
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2019, 113 : 379 - 391
  • [3] Ultrafast separations via pulse flow valve modulation to enable high peak capacity multidimensional gas chromatography
    Bahaghighat, H. Daniel
    Freye, Chris E.
    Gough, Derrick V.
    Sudol, Paige E.
    Synovec, Robert E.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2018, 1573 : 115 - 124
  • [4] Flow Field Thermal Gradient Gas Chromatography
    Boeker, Peter
    Leppert, Jan
    [J]. ANALYTICAL CHEMISTRY, 2015, 87 (17) : 9033 - 9041
  • [5] Partial modulation method via pulsed flow modulator for comprehensive two-dimensional gas chromatography
    Cai, HM
    Stearns, SD
    [J]. ANALYTICAL CHEMISTRY, 2004, 76 (20) : 6064 - 6076
  • [6] STATISTICAL-THEORY OF SPOT OVERLAP FOR N-DIMENSIONAL SEPARATIONS
    DAVIS, JM
    [J]. ANALYTICAL CHEMISTRY, 1993, 65 (15) : 2014 - 2023
  • [7] DAVIS JM, 1983, ANAL CHEM, V55, P418, DOI 10.1021/ac00254a003
  • [8] STATISTICAL-METHOD FOR ESTIMATION OF NUMBER OF COMPONENTS FROM SINGLE COMPLEX CHROMATOGRAMS - THEORY, COMPUTER-BASED TESTING, AND ANALYSIS OF ERRORS
    DAVIS, JM
    GIDDINGS, JC
    [J]. ANALYTICAL CHEMISTRY, 1985, 57 (12) : 2168 - 2177
  • [9] GCxGC Quantification of Priority and Emerging Nonpolar Halogenated Micropollutants in All Types of Wastewater Matrices: Analysis Methodology, Chemical Occurrence, and Partitioning
    Dimitriou-Christidis, Petros
    Bonvin, Alex
    Samanipour, Saer
    Hollender, Juliane
    Rutler, Rebecca
    Westphale, Jimmy
    Gros, Jonas
    Arey, J. Samuel
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2015, 49 (13) : 7914 - 7925
  • [10] Simultaneous on-line monitoring of propofol and sevoflurane in balanced anesthesia by direct resistive heating gas chromatography
    Dong, Hao
    Zhang, Feng Jiang
    Wang, Fu Yuan
    Wang, Ying Ying
    Guo, Jing
    Kanhar, G. M.
    Chen, Jing
    Liu, Jun
    Zhou, Chen
    Yan, Min
    Chen, Xing
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2017, 1506 : 93 - 100