Analysis of feasibility of floor radiant cooling system combined with displacement ventilation

被引:0
|
作者
Li, DY [1 ]
Ren, YL [1 ]
Wang, ZJ [1 ]
机构
[1] Beijing Inst Civil Engn & Architecture, Beijing, Peoples R China
关键词
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
Along with the rapid popularization of radiant floor heating, the feasibility of radiant floor cooling is strongly interested. This paper analyses its merits and limits, and puts forward that the combination of radiant floor cooling and displacement ventilation could exert both of their merits. As the heat transfer between the floor and space in floor cooling system is mostly in the form of radiation, the indoor temperature field distribution is even. But its cooling capacity is limited by the dew point of the air in the space. The dry air layer near the floor formed by displacement ventilation system can effectively prevent drew on the surface of the floor in summer, and increase its cooling capacity. This hybrid system can provide a high standard of thermal comfort and indoor air quality in higher cooling load. Furthermore, it also can provide many energy conservation possibilities. In addition, this paper discusses the feasibility of floor cooling system with a combination of displacement ventilation in summer.
引用
收藏
页码:634 / 637
页数:4
相关论文
共 50 条
  • [21] Numerical simulation of radiant floor cooling system
    Jin, Xing
    Zhang, Xiaosong
    Cao, Rongquan
    Cao, Yiran
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2010, 31 (06): : 732 - 737
  • [22] Experimental Study on Performance Comparison Between Heavy and Lightweight Radiant Floor Cooling Combined with Underfloor Ventilation Air Conditioning System
    Zhang, Dongliang
    Cai, Ning
    Rui, Yingxiang
    Tang, Hu
    Liu, Minghui
    PROCEEDINGS OF THE 8TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, VOL 2: HVAC&R COMPONENT AND ENERGY SYSTEM, 2014, 262 : 475 - 483
  • [23] A Study on Heating Characteristics of The Combined Radiant Floor Heating & Cooling System with Uneven Tubing
    Li, Qingqing
    Chen, Chao
    Lin, Jie
    Zhang, Ye
    Li, Zhuo
    Wu, Pin
    6TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I-III, PROCEEDINGS, 2009, : 366 - 372
  • [24] A study for evaluating performance of radiant floor cooling integrated with controlled ventilation
    Leigh, SB
    Song, DS
    Hwang, SH
    Lee, SY
    ASHRAE Transactions 2005, Vol 111, Pt 1, 2005, 111 : 71 - 82
  • [25] Experimental study on the operating characteristic of a combined radiant floor and fan coil cooling system
    Zhu, Xuwei
    Su, Meng
    Han, Xiaojing
    Zheng, Changjin
    Liu, Jiying
    Cheng, Yuanda
    ENERGY AND BUILDINGS, 2024, 325
  • [26] A Comparative Analysis of Machine Learning Algorithms in Predicting the Performance of a Combined Radiant Floor and Fan Coil Cooling System
    Lu, Shengze
    Cui, Mengying
    Gao, Bo
    Liu, Jianhua
    Ni, Ji
    Liu, Jiying
    Zhou, Shiyu
    BUILDINGS, 2024, 14 (06)
  • [27] Study on Indoor Air Quality of Ceiling Radiant Cooling Panel System Integrated with Displacement Ventilation
    Du, Jing
    Li, Nianping
    PROCEEDINGS OF THE 8TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, VOL 1: INDOOR AND OUTDOOR ENVIRONMENT, 2014, 261 : 497 - 505
  • [28] Radiant Floor Cooling in Practice
    Dieckmann, John
    McKenney, Kurtis
    Brodrick, James
    ASHRAE JOURNAL, 2009, 51 (11) : 70 - +
  • [29] Radiant floor cooling systems
    Olesen, Bjarne
    ASHRAE JOURNAL, 2008, 50 (09) : 16 - +
  • [30] Feasibility of a Radiant Floor Cooling System for Residential Buildings with Massive Concrete Slab in a Hot and Humid Climate
    Chang-Ho Jeong
    Myoung-Souk Yeo
    Kwang-Woo Kim
    International Journal of Concrete Structures and Materials, 2018, 12