Accuracy of A Handheld Accelerometer-Based Navigation System for Femoral and Tibial Resection in Total Knee Arthroplasty

被引:29
作者
Huang, Eddie H. [1 ]
Copp, Steven N. [2 ]
Bugbee, William D. [2 ]
机构
[1] Univ Texas Houston, Hlth Sci Ctr, Houston, TX USA
[2] Scripps Clin, Div Orthopaed Surg, La Jolla, CA 92037 USA
关键词
total knee arthroplasty; navigation; computer-assisted surgery; alignment; replacement; COMPUTER NAVIGATION; ALIGNMENT SYSTEMS; INTRAMEDULLARY; EXTRAMEDULLARY; GUIDES; INSTRUMENTATION; REPLACEMENT; FAILURE; WEAR;
D O I
10.1016/j.arth.2015.05.055
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Restoration of mechanical axis in total knee arthroplasty (TKA) is correlated with improved implant survivorship. We assessed the accuracy and required surgical time using a hand-held accelerometer-based navigation system for TKA. Data collected on 53 patients included assembly, resection, and tourniquet times. Implant alignment and mechanical axis were measured on radiographs. Femoral alignment was 0.29 degrees +/- 2.2 degrees varus. Tibial alignment was 0.09 degrees +/- 1.4 degrees valgus. Postoperative mechanical axis was 0.2 degrees +/- 2.1 degrees varus. Malalignment rates for the femur, tibia, and axis were 13%, 3.8%, and 17%, respectively. Average time for pinning and navigating was 3.6 minutes for the femur and 2.6 minutes for the tibia; mean tourniquet time was 62 minutes. This navigation system accurately re-established mechanical axis without increasing surgical time. (C) 2015 Elsevier Inc. All rights reserved.
引用
收藏
页码:1906 / 1910
页数:5
相关论文
共 21 条
[1]   Computer assisted navigation in total knee arthroplasty - Comparison with conventional methods [J].
Anderson, KC ;
Buehler, KC ;
Markel, DC .
JOURNAL OF ARTHROPLASTY, 2005, 20 (07) :132-138
[2]   Tibial component failure mechanisms in total knee arthroplasty [J].
Berend, ME ;
Ritter, MA ;
Meding, JB ;
Faris, PM ;
Keating, EM ;
Redelman, R ;
Faris, GW ;
Davis, KE .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (428) :26-34
[3]   Computer-Assisted Techniques Versus Conventional Guides for Component Alignment in Total Knee Arthroplasty [J].
Blakeney, William G. ;
Khan, Riaz J. K. ;
Wall, Simon J. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2011, 93A (15) :1377-1384
[4]  
CATES HE, 1993, CLIN ORTHOP RELAT R, P32
[5]  
Dennis D A, 1993, J Arthroplasty, V8, P43, DOI 10.1016/S0883-5403(06)80106-3
[6]  
Engh G A, 1990, J Arthroplasty, V5, P1, DOI 10.1016/S0883-5403(06)80002-1
[7]  
Flint JM, 2007, PONG CAOS SHORT HIST
[8]   CORONAL ALIGNMENT AFTER TOTAL KNEE REPLACEMENT [J].
JEFFERY, RS ;
MORRIS, RW ;
DENHAM, RA .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (05) :709-714
[9]   Unsatisfactory Accuracy as Determined by Computer Navigation of VISIONAIRE Patient-Specific Instrumentation for Total Knee Arthroplasty [J].
Lustig, Sebastien ;
Scholes, Corey J. ;
Oussedik, Sam I. ;
Kinzel, Vera ;
Coolican, Myles R. J. ;
Parker, David A. .
JOURNAL OF ARTHROPLASTY, 2013, 28 (03) :469-473
[10]   Meta-Analysis of Alignment Outcomes in Computer-Assisted Total Knee Arthroplasty Surgery [J].
Mason, J. Bohannon ;
Fehring, Thomas K. ;
Estok, Rhonda ;
Banel, Deirdre ;
Fahrbach, Kyle .
JOURNAL OF ARTHROPLASTY, 2007, 22 (08) :1097-1106