A comparison of survey methods for detecting bobcats

被引:0
|
作者
Harrison, RL [1 ]
机构
[1] Univ New Mexico, Dept Biol, Albuquerque, NM 87131 USA
关键词
bobcat; camera; detector dog; hair-snare; Lynx rufus; scat; scent station;
D O I
10.2193/0091-7648(2006)34[548:ACOSMF]2.0.CO;2
中图分类号
X176 [生物多样性保护];
学科分类号
090705 ;
摘要
Population trends in bobcats (Lynx rufus) have been difficult to monitor because traditional field survey methods usually produce very low detection rates. However, new methods of detecting bobcats have been developed. I compared the rate of detection, cost, and time required for automatic cameras, hair-snares, scent stations, and a detector dog trained to find bobcat scats. The detector dog produced nearly 10 times the number of bobcat detections as the other methods combined. The detector dog was the most expensive method and, depending upon weather and number of scats required, required more field time than the other methods. However use of detector dogs requires only one visit to each survey site. Hair-snares and scent stations were the cheapest methods but produced the least detections. Field time for hair-snares, cameras, and scent stations was similar. Use of detector dogs has the potential to consistently achieve sufficient detection rates to provide useful indices for population monitoring of bobcats.
引用
收藏
页码:548 / 552
页数:5
相关论文
共 50 条
  • [21] COMPARISON OF DIFFERENT METHODS FOR DETECTING OVULATION IN CATTLE
    HOWES, JR
    WARNICK, AC
    HENTGES, JF
    FERTILITY AND STERILITY, 1960, 11 (05) : 508 - 517
  • [22] A Comparison of Methods for Detecting Examinee Preknowledge of Items
    Wang, Xi
    Liu, Yang
    Robin, Frederic
    Guo, Hongwen
    INTERNATIONAL JOURNAL OF TESTING, 2019, 19 (03) : 207 - 226
  • [23] COMPARISON OF 3 METHODS FOR DETECTING ANTIBODY TO CYTOMEGALOVIRUS
    TASWELL, HF
    REISNER, RK
    RABE, DE
    SHELLEY, CD
    SMITH, TF
    TRANSFUSION, 1986, 26 (03) : 285 - 289
  • [24] DETECTING FETOMATERNAL HEMORRHAGE - A COMPARISON OF 5 METHODS
    BAYLISS, KM
    KUECK, BD
    JOHNSON, ST
    FUEGER, JT
    MCFADDEN, PW
    MIKULSKI, D
    GOTTSCHALL, JL
    TRANSFUSION, 1991, 31 (04) : 303 - 307
  • [25] Comparison of computerized methods for detecting the ventilatory thresholds
    Edil Luis Santos
    Antonio Giannella-Neto
    European Journal of Applied Physiology, 2004, 93 : 315 - 324
  • [26] Detecting early recovery of consciousness: a comparison of methods
    Day, Kristin V.
    DiNapoli, Michael V.
    Whyte, John
    NEUROPSYCHOLOGICAL REHABILITATION, 2018, 28 (08) : 1233 - 1241
  • [27] COMPARISON OF METHODS FOR DETECTING KERATOCONUS USING VIDEOKERATOGRAPHY
    MAEDA, N
    KLYCE, SD
    SMOLEK, MK
    ARCHIVES OF OPHTHALMOLOGY, 1995, 113 (07) : 870 - 874
  • [28] A TEST OF THE SCENT-STATION SURVEY TECHNIQUE FOR BOBCATS
    DIEFENBACH, DR
    CONROY, MJ
    WARREN, RJ
    JAMES, WE
    BAKER, LA
    HON, T
    JOURNAL OF WILDLIFE MANAGEMENT, 1994, 58 (01): : 10 - 17
  • [29] Comparison of survey and physician claims data for detecting hypertension
    Muhajarine, N
    Mustard, C
    Roos, LL
    Young, TK
    Gelskey, DE
    JOURNAL OF CLINICAL EPIDEMIOLOGY, 1997, 50 (06) : 711 - 718
  • [30] Survey of inpatient satisfaction:: comparison of different survey methods
    Labarère, J
    François, P
    Bertrand, D
    Fourny, M
    Olive, F
    Peyrin, JC
    PRESSE MEDICALE, 2000, 29 (20): : 1112 - 1114